Comparative Performance of 64Copper [64Cu]-SAR-bis-PSMA vs 68Ga PSMA-11 PET CT for the Detection of Prostate Cancer Recurrence in the Setting of Biochemical Failure Following Radical Prostatectomy (Co-PSMA)
The goal of this clinical trial is to compare 64Cu-SAR-bisPSMA PET/CT and 68Ga PSMA-11 PET/CT in men with biochemical failure following radical prostatectomy. The main questions it aims to answer are:
- Is there a difference in the number of lesions of prostate cancer recurrence detected between the 64Cu-SAR-bisPSMA PET/CT and 68Ga PSMA-11 PET/CT scans.
- What is the diagnostic accuracy of 64Cu-SAR-bisPSMA PET/CT compared to 68Ga PSMA-11 PET/CT using a standard of care comparator.
- Evaluate the magnitude of clinical management change when using 64Cu-SAR-bisPSMA additional to standard of care imaging (68Ga PSMA-11).
Participants will:
- have 3 visits: 1) standard of care 68Ga PSMA-11 dose and PET/CT scan; 2) 64Cu-SAR-bisPSMA dose and PET/CT; 3) 64Cu-SAR-bisPSMA PET/CT only
- have standard of care blood test either at Visit 1 or Visit 2
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 2
Contacts and Locations
Study Contact
Study Contact
- Name: Sobia Khan, MBBS, FRACP
- Phone Number: +61 0283821830
- Email: svhs.nm@svha.org.au
Study Contact Backup
- Name: Louise Emmett, MBChB, FRACP, MD, FAANMS
- Phone Number: +61 0283821830
- Email: louise.emmett@svha.org.au
Study Locations
-
-
New South Wales
-
Darlinghurst, New South Wales, Australia, 2010
- St Vincent's Hospital, Sydney
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Male patients aged 18 or above
- Ability to provide informed consent documentation indicating that they understand the purpose of, and procedures required for the study, and are willing to participate in the study.
- Prior radical prostatectomy for confirmed adenocarcinoma on histopathology.
- Rising PSA (0.20 - 0.75 ng/mL) following radical prostatectomy with no prior salvage radiotherapy.
- 68Ga PSMA-11 PET/CT within the last 4 weeks for prostate cancer biochemical recurrence.
Exclusion Criteria:
- Prior, or contraindication to, salvage radiotherapy for biochemically recurrent prostate cancer.
- History of current active malignancy as per investigator discretion other than prostate cancer.
- Known or expected hypersensitivity to 64Cu-SAR-bisPSMA
- Systemic therapy for metastatic prostate cancer including androgen deprivation therapy.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: 64Cu-SAR-bisPSMA
200MBq 64Cu-SAR-bisPSMA
|
All participants will receive a single administration of 200 MBq of 64Cu-SAR-bisPSMA
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Detection rate of lesions per participants, between 64Cu-SAR-bisPSMA and 68Ga PSMA-11 PET/CT
Time Frame: 12 months
|
Compare the detection rate of sites of prostate cancer recurrence, as determined by number of lesions per participants, between 64Cu-SAR-bisPSMA and 68Ga PSMA-11 PET/CT in patients with biochemical recurrence following radical prostatectomy who are being considered for curative salvage radiotherapy.
|
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Compare the number of lesions outside of the prostatic fossa per patient between 64Cu-SAR-bisPSMA and 68Ga PSMA-11 PET/CT.
Time Frame: 12 months
|
12 months
|
|
|
Compare the diagnostic accuracy of 64Cu-SAR-bisPSMA versus 68Ga PSMA-11 PET/CT in the detection of recurrent or metastatic prostate cancer using a composite standard of truth
Time Frame: 12 months
|
Compare the diagnostic accuracy of 64Cu-SAR-bisPSMA versus 68Ga PSMA-11 PET/CT in the detection of recurrent or metastatic prostate cancer using a composite standard of truth (biopsy, concurrent imaging and response to targeted therapy).
|
12 months
|
|
Evaluate the magnitude of clinical management change when using 64Cu-SAR-bisPSMA additional to standard of care imaging (68Ga PSMA-11).
Time Frame: 12 months
|
12 months
|
|
|
Compare the total number of lesions between 1 to 4-hour, and 24-hour 64Cu-SAR-bisPSMA PET/CT imaging timepoints.
Time Frame: 12 months
|
12 months
|
|
|
Evaluate the frequency of prostatic fossa recurrence on the 24-hour 64Cu-SAR-bisPSMA images compared to the 1 to 4-hour 64Cu-SAR-bisPSMA and 1-hour 68Ga PSMA-11 PET/CT images
Time Frame: 12 months
|
12 months
|
|
|
Evaluate biochemical (PSA) response following salvage radiotherapy by 64Cu-SAR-bisPSMA and 68Ga PSMA-11 PET/CT imaging parameters in the presence of normal testosterone levels.
Time Frame: 12 months
|
12 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CLP11 (Co-PSMA)
- CT-2024-CTN-06035-1 (Other Identifier: Therapeutic Goods Administration)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.