Optimizing Noisy Galvanic Vestibular Stimulation Frequency Range for Enhancing Vestibular Perception and Manual Control Performance
Assessments of Performance in Healthy Control Subjects
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Texas
-
Houston, Texas, United States, 77058
- Nasa Jsc B21
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Subjects were required to pass a physical exam adminisitrated by NASA JSC Clinic.
Exclusion Criteria:
- No history of neurologic, vestibular, or autonomic disease.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
No Intervention: Control - No noisy galvanic vestibular stimulation
Participants completed testing without noisy galvanic vestibular stimulation.
|
|
|
Experimental: Low-frequency noisy galvanic vestibular stimulation
Participants received low-frequency noisy galvanic vestibular stimulation during testing.
Low frequency was 0-2 Hz.
|
Participants received low-frequency noisy galvanic vestibular stimulation through electrodes placed over the bilateral mastoid processes during experimental testing.
Stimulation parameters were consistent with the approved study protocol.
Frequency was 0-2Hz white noise, 300uA amplitude.
|
|
Experimental: High-frequency noisy galvanic vestibular stimulation
Participants received high-frequency noisy galvanic vestibular stimulation during testing.
High-frequency was 10-30 Hz.
|
Participants received high-frequency noisy galvanic vestibular stimulation through electrodes placed over the bilateral mastoid processes during experimental testing.
Stimulation parameters were consistent with the approved study protocol.
Frequency was 10-30Hz white noise, 300uA amplitude.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Vestibular Direction Recognition Threshold
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Vestibular perceptual sensitivity was assessed using roll-tilt and interaural translation direction recognition tasks performed on a six-degree-of-freedom motion platform.
Direction recognition thresholds were estimated from participant responses using an adaptive three-down, one-up staircase procedure and cumulative Gaussian psychometric curve fitting.
Lower threshold values indicate greater vestibular sensitivity and improved perception of self-motion.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Perceptual Motion Tracking Accuracy
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Perceptual motion tracking performance was evaluated during continuous pseudorandom roll motion.
Participants used a joystick to continuously indicate their perceived direction and magnitude of platform motion.
Performance was quantified using the root mean square error (RMSE) between joystick responses and the programmed motion stimulus, with lower RMSE values indicating more accurate perception and tracking of self-motion.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Manual Control Nulling Accuracy
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Manual control performance was evaluated during continuous pseudorandom roll motion while participants used a joystick to actively minimize platform motion by generating corrective control inputs.
Performance was quantified using the root mean square error (RMSE) between the platform tilt angle and the upright position over time.
Lower RMSE values indicate more effective manual control and disturbance rejection.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Roll-Tilt Vestibular Direction Recognition Threshold
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Vestibular perceptual threshold for roll-tilt motion was measured using a computerized three-down, one-up adaptive staircase procedure during a 1 Hz sinusoidal motion stimulus.
Thresholds were estimated by fitting a cumulative Gaussian psychometric function to participants' left/right direction recognition responses.
Lower threshold values indicate greater vestibular sensitivity.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Interaural Translation Vestibular Direction Recognition Threshold
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Vestibular perceptual threshold for interaural translation motion was measured using a computerized three-down, one-up adaptive staircase procedure during a 1 Hz sinusoidal motion stimulus.
Thresholds were estimated by fitting a cumulative Gaussian psychometric function to participants' left/right direction recognition responses.
Lower threshold values indicate greater vestibular sensitivity.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Vestibular Direction Recognition Bias
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Response bias during the vestibular direction recognition task was estimated from the mean of the cumulative Gaussian psychometric function.
Bias represents the stimulus magnitude at which participants were equally likely to perceive motion in either direction, providing a measure of systematic perceptual offset.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Perceptual Motion Tracking Variability
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Variability of perceptual motion tracking performance during continuous pseudorandom roll motion.
Tracking variability was quantified using statistical measures including standard deviation and variance of tracking performance, providing an assessment of the consistency and precision of participant responses.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
|
Manual Control Nulling Variability
Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Variability of manual control performance during the nulling task was quantified using standard deviation, variance, and mean absolute deviation of chair tilt relative to the upright position.
These measures assessed the consistency and precision of participants' ability to minimize platform motion.
|
Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Scott J Wood, PhD, National Aeronautics and Space Administration (NASA)
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- eIRB Study 0530
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- SAP
- ANALYTIC_CODE
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.