Accuracy of the Calibrated Framework for Intra Oral Full Arch Scan (A Cross-over Study)

September 30, 2026 updated by: Noor Elhoda Alkhalil, Mansoura University

Accuracy of the Calibrated Framework for Intraoral Full-Arch Scanning Compared With Conventional Splinted Open-Tray Impression in Edentulous Patients: A Crossover Clinical Trial

This crossover clinical trial aims to compare the accuracy of conventional splinted open-tray implant impressions with intraoral digital scanning using a calibrated framework in completely edentulous patients rehabilitated with full-arch implant-supported prostheses. Accurate transfer of implant positions is essential for achieving a passive fit of the prosthetic framework and minimizing biological and mechanical complications.

Twenty healthy completely edentulous patients requiring full-arch implant rehabilitation will be enrolled. Each participant will undergo both conventional and digital impression techniques following implant placement, allowing direct within-subject comparison. The conventional technique consists of a verified splinted open-tray impression, while the digital technique uses an intraoral scanner in combination with a calibrated stock framework.

The accuracy of the two impression techniques will be evaluated by superimposing the resulting STL files using Geomagic Control X software. Linear deviations in the x-, y-, and z-axes, angular deviations, and global deviations will be measured and compared. The findings of this study are expected to provide clinical evidence regarding the accuracy of calibrated framework-assisted intraoral scanning compared with the conventional impression technique for full-arch implant rehabilitation.

Study Overview

Status

Recruiting

Conditions

Intervention / Treatment

Detailed Description

The passive fit of full-arch implant-supported prostheses is a critical factor influencing the long-term success of implant rehabilitation. Because dental implants lack a periodontal ligament, inaccuracies in transferring implant positions may result in framework misfit, leading to biological and mechanical complications such as screw loosening, component fracture, or implant failure. Conventional splinted open-tray impressions are considered the reference standard for full-arch implant impressions; however, they are technique-sensitive, time-consuming, and susceptible to material distortion and operator-related errors.

Advances in digital dentistry have enabled the use of intraoral scanners for implant impressions. Nevertheless, complete-arch digital scanning remains challenging because cumulative stitching errors may reduce scanning accuracy. The use of a calibrated framework has recently been proposed to improve the accuracy of complete-arch intraoral scanning by providing stable geometric reference points during image acquisition. Although promising, clinical evidence comparing this technique with the conventional splinted open-tray impression technique remains limited.

The purpose of this crossover clinical trial is to compare the accuracy of conventional splinted open-tray impressions and intraoral digital scanning using a calibrated framework in completely edentulous patients receiving full-arch implant rehabilitation.

Twenty healthy completely edentulous patients will be recruited. Following implant placement, each participant will undergo both impression techniques. The conventional workflow will consist of a verified splinted open-tray implant impression, while the digital workflow will involve intraoral scanning using a calibrated stock framework attached to implant scan bodies. STL datasets obtained from both techniques will be analyzed using Geomagic Control X software. The digital models will be superimposed to assess linear deviations along the x-, y-, and z-axes, angular deviations, and global three-dimensional deviations. The results will be statistically analyzed to determine whether the calibrated framework-assisted digital workflow provides transfer accuracy comparable to or greater than the conventional impression technique.

Study Type

Interventional

Enrollment (Estimated)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Al Mansurah, Egypt, 12345
        • Recruiting
        • Noor Alhuda Rahemm Khalil
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

35 years to 60 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous maxilla and mandible for at least 6 months following the last tooth extraction.
  • Angle's Class I maxillomandibular relationship with adequate interarch space.
  • Sufficient residual alveolar bone quantity and quality to receive dental implants.
  • Good oral hygiene.
  • Free from uncontrolled systemic diseases or conditions that may interfere with implant osseointegration.
  • Able and willing to provide written informed consent.

Exclusion Criteria:

  • Temporomandibular joint disorders or parafunctional habits.
  • Heavy smokers.
  • Uncontrolled systemic diseases.
  • History of chemotherapy or radiotherapy to the head and neck region.
  • Poor neuromuscular coordination.
  • Localized bone defects that could compromise implant placement.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: Non-Randomized
  • Interventional Model: Crossover Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Conventional Splinted Open-Tray Impression

Participants will undergo a conventional verified splinted open-tray implant impression following implant placement. Impression copings will be splinted using dental floss and autopolymerizing resin, and a polyvinyl siloxane (PVS) impression will be made. The resulting master cast will be digitized using a laboratory scanner to generate an STL file for accuracy assessment.

A conventional verified splinted open-tray implant impression will be performed after implant placement. Multi-unit impression copings will be splinted using dental floss and autopolymerizing resin, followed by a polyvinyl siloxane (PVS) impression. The master cast will be fabricated, verified, and scanned with a laboratory scanner to generate an STL file for accuracy analysis.

Other Names:
  • Conventional Implant Impression Open-Tray Impression Splinted Open-Tray Technique
Experimental: Intraoral Digital Scanning with Calibrated Framework

Participants will undergo intraoral digital scanning using an intraoral scanner and a calibrated stock framework attached to implant scan bodies after implant placement. The generated STL file will be compared with the conventional impression using Geomagic Control X software to evaluate transfer accuracy.

An intraoral digital impression will be obtained after implant placement using an intraoral scanner and a calibrated stock framework attached to implant scan bodies. The resulting STL dataset will be compared with the conventional impression using Geomagic Control X software to evaluate linear, angular, and global deviations in implant position transfer accuracy.

Other Names:
  • Calibrated Framework Technique Intraoral Digital Impression Full-Arch Intraoral Scanning

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Implant Position Transfer Accuracy (Linear deviations)
Time Frame: Immediately after impression procedures following implant placement (same study visit).

by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software. Linear deviations (x-, y-, and z-axes)

Immediately after impression procedures following implant placement (same study visit).

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Implant Position Transfer Accuracy (Angular deviations)
Time Frame: Immediately after impression procedures following implant placement (same study visit).

Accuracy of implant position transfer will be assessed by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software

Immediately after impression procedures following implant placement (same study visit).

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Study Chair: osama asker, PHD, Mansoura University

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 1, 2026

Primary Completion (Estimated)

February 1, 2027

Study Completion (Estimated)

April 1, 2027

Study Registration Dates

First Submitted

July 2, 2026

First Submitted That Met QC Criteria

September 30, 2026

First Posted (Actual)

October 5, 2026

Study Record Updates

Last Update Posted (Actual)

October 5, 2026

Last Update Submitted That Met QC Criteria

September 30, 2026

Last Verified

September 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • MS.26.01.135

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

upon request from the corresponding author

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.