Mi2000 TICI - Post-market Implantation Study (TUPIS)
This Post-Market Clinical Follow-up (PMCF) investigation aims to further collect evidence on safety and performance of the Mi2000 TICI. This PMCF investigation will prospectively collect clinical data from the use of the Mi2000 TICI and related devices.
This PMCF investigation is performed on a cochlear implant system newly introduced to the market, which was previously studied in two pre-market clinical investigations. The purpose of the current clinical investigation is to collect further evidence by collecting additional clinical data on the use of the Mi2000 TICI.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Florian Schwarze, PhD
- Phone Number: +4357788
- Email: studies@medel.com
Study Locations
-
-
State of Vienna
-
Vienna, State of Vienna, Austria, 1090
- Not yet recruiting
- AKH Wien
-
Contact:
- Christoph Arnoldner, Prof. Dr.
- Email: christoph.arnoldner@meduniwien.ac.at
-
-
-
-
-
Liège, Belgium, 4000
- Not yet recruiting
- Centre Hospitalier Universitaire de Liège, Department ORL
-
Contact:
- Philippe Lefebvre, Dr.med.
-
-
Belgium
-
Antwerp, Belgium, Belgium, 2650
- Not yet recruiting
- UZA Antwerpen
-
Contact:
- Vincent van Rompaey, Prof. Dr.
-
-
-
-
-
Würzburg, Germany
- Not yet recruiting
- Universitätsklinikum Würzburg
-
Contact:
- Kristen Rak, Prof. Dr.
-
-
Bavaria
-
München, Bavaria, Germany, 81377
- Recruiting
- Klinikum der Universität München, Campus Großhadern
-
Contact:
- Joachim Müller, Dr.med.
-
-
-
-
Poland
-
Nadarzyn, Poland, Poland, 05-830
- Not yet recruiting
- The Institute of Physiology and Pathology of Hearing
-
Contact:
- Piotr Skarzynski, Prof. Dr.
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Minimum age of eighteen (18) years at time of enrolment
- Bilateral sensorineural hearing loss with no or limited benefit from a hearing aid (>70 dB HL PTA4(500, 1000, 2000, 4000Hz))
- Post-lingual onset of deafness
- No or limited benefit from hearing aids for less than 10 years and an expected benefit from cochlear implantation
- A maximum score of 50% on a word test in the language of the test center in the ear to be implanted in the best aided condition
- Fluency in the test language with excellent proficiency, as appropriate to perform speech testing
- Functional auditory nerve
- General health condition, psychological and emotional condition deemed compatible with the treatment and tests performed in this study
- Pre-operative assessment according to the local professional standards
- Candidate is highly motivated and has realistic expectations about the expected benefit of the implant and shall understand the importance of returning to the implant center for regular speech processor programming, assessment sessions and training
- Realistic expectations, as deemed appropriate by the implanting surgeon/implant board
- Signed and dated informed consent before the start of any study-specific procedure
Exclusion Criteria:
-
Lack of compliance with any inclusion criterion
-
Previously having received an implant on the location chosen for placing the cochlear implant
-
Having received a hearing implant from another manufacturer than MED-EL on the contralateral ear
-
Pre-existing condition known to necessitate MRI scans after implantation of the Mi2000 TICI
-
Women being pregnant or nursing
-
The individual is known to be intolerant of the materials used in the implant or other required accessories
-
Absence of cochlear development
-
The cause of deafness is non-functionality of the auditory nerve and/or the upper auditory pathway
-
Medical contra-indications to middle ear and/or inner ear surgery, and/or anesthesia
-
External or middle ear infections are present
-
The tympanic membrane is perforated in the ear to be implanted
-
Anatomic abnormalities are present that would prevent appropriate placement of the stimulator housing in the bone of the skull, or prevent placement of the chosen electrode array into the cochlea (including ossification of the cochlea)
-
The psychological status of the individual is unstable
-
The individual has unrealistic expectations
-
Acute cholesteatoma
-
History of vestibular schwannoma
-
Unstable Meniere's disease
-
Auditory Neuropathy
-
Epilepsy not responding to treatment
-
Permanent inability and/or unwillingness to participation in post-operative care and rehabilitation
-
Known intellectual disability and/or psychological diseases
-
Participation in other pharmacological clinical trials within four weeks prior to enrolment
-
Anything that, in the opinion of the Investigator, would
- place the subject at increased risk
- preclude the subject's full compliance with or completion of the study
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: TICI recipients
Participants in this clinical investigation will be implanted with an Mi2000 TICI totally cochlear implant |
Participants in this clinical investigation will receive a totally implantable cochlear implant. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Word Test in Quiet
Time Frame: Pre-op to 6 months after first fitting
|
Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
Pre-op to 6 months after first fitting
|
|
Sentence Test in Noise
Time Frame: Pre-op to 6 months after first fitting
|
Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
Pre-op to 6 months after first fitting
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Health Utility Index Mark 3 (HUI3)
Time Frame: Pre-op to 6 months after first fitting
|
Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
Pre-op to 6 months after first fitting
|
|
Nijmegen Cochlear Implant Questionnaire (NCIQ)
Time Frame: Pre-op to 6 months after first fitting
|
Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
Pre-op to 6 months after first fitting
|
|
Change in body sound perception
Time Frame: through study completion, an average of 12 months after first fitting
|
Participant reported scale on body sound perception (0 - no disturbance to 10 - very disturbing) |
through study completion, an average of 12 months after first fitting
|
|
Change in stigma perception
Time Frame: through study completion, an average of 12 months after first fitting
|
Participant reported scale on stigma perception (0 - no stigmatization to 10 - strong stigmatization) |
through study completion, an average of 12 months after first fitting
|
|
Change in comfort perception
Time Frame: through study completion, an average of 12 months after first fitting
|
Participant reported scale on stigma perception (0 - not comfortable to 10 - very comfortable) |
through study completion, an average of 12 months after first fitting
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Word test in quiet
Time Frame: through study completion, an average of 12 months after first fitting
|
Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Sentence Test in Noise
Time Frame: through study completion, an average of 12 months after first fitting
|
Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Health Utility Index Mark 3 (HUI3)
Time Frame: through study completion, an average of 12 months after first fitting
|
Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
through study completion, an average of 12 months after first fitting
|
|
Nijmegen Cochlear Implant Questionnaire (NCIQ)
Time Frame: through study completion, an average of 12 months after first fitting
|
Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Speech, Spatial, Quality of Hearing (SSQ12)
Time Frame: through study completion, an average of 12 months after first fitting
|
Speech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Hearing Implant Sound Quality Index (HISQUI)
Time Frame: through study completion, an average of 12 months after first fitting
|
Sound quality score ranging from 19 (very poor sound quality) to 133 (very good sound quality) |
through study completion, an average of 12 months after first fitting
|
|
Tinnitus Functional Index (TFI)
Time Frame: through study completion, an average of 12 months after first fitting
|
Tinnitus questionnaire measures the severity and negative impact of tinnitus on a 0 (Not a Problem / Slight Tinnitus) to 100 (Very Big Problem / Very Severe Tinnitus) scale |
through study completion, an average of 12 months after first fitting
|
|
Audiogram
Time Frame: through study completion, an average of 12 months after first fitting
|
Pure-tone air-conduction hearing thresholds will be measured in each ear. The threshold is the lowest sound level, in decibels hearing level (dB HL), at which the participant responds. The outcome is the threshold at each frequency. Higher thresholds mean poorer hearing; lower thresholds better hearing. |
through study completion, an average of 12 months after first fitting
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Florian Schwarze, MED-EL
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
- Neurologic Manifestations
- Nervous System Diseases
- Otorhinolaryngologic Diseases
- Sensation Disorders
- Ear Diseases
- Hearing Disorders
- Pathological Conditions, Signs and Symptoms
- Signs and Symptoms
- Hearing Loss
- Surgical Procedures, Operative
- Prosthesis Implantation
- Otorhinolaryngologic Surgical Procedures
- Otologic Surgical Procedures
- Cochlear Implantation
Other Study ID Numbers
Other Study ID Numbers
- MED-EL_CRD_2026_03
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.