Efficacy and Safety of Dual-Effect Myopia Control Lenses for Slowing Myopia Progression: A Single-Center, Randomized, Controlled, Noninferiority Trial

This study aims to evaluate the efficacy and safety of dual-effect myopia control spectacle lenses in slowing myopia progression compared with Nikon MyoEase 2.0 lenses in children aged 8-13 years.

This is a single-center, randomized, open-label, parallel-group, noninferiority clinical trial. A total of 194 children with myopia will be randomly assigned in a 1:1 ratio to wear either dual-effect myopia control spectacle lenses or Nikon MyoEase 2.0 lenses for 12 months.

The primary outcome is the change in cycloplegic objective spherical equivalent refraction from baseline to 12 months. Secondary outcomes include changes in refractive error, ocular biometric parameters, visual acuity, binocular visual function, and visual questionnaire scores. Safety will also be assessed throughout the study.

Study Overview

Status

Not yet recruiting

Conditions

Intervention / Treatment

Study Type

Interventional

Enrollment (Estimated)

194

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

8 years to 13 years (Child)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Aged 8-13 years, regardless of sex, with written consent from both the participant and their legal guardian.
  2. Cycloplegic objective spherical equivalent refraction between -4.75 D and -0.75 D (inclusive) in both eyes, astigmatism ≥-1.50 D, and an absolute interocular difference in spherical equivalent refraction ≤1.00 D.
  3. Best-corrected visual acuity ≥1.0 in both eyes.
  4. Intraocular pressure within the normal range (10-21 mmHg) in both eyes.
  5. Voluntary participation in the study with signed informed consent.

Exclusion Criteria:

  1. History of ocular trauma or intraocular surgery.
  2. Clinically abnormal slit-lamp examination findings.
  3. Fundus examination grade ≥2.
  4. Other ocular diseases, including uveitis or other ocular inflammation, glaucoma, cataract, fundus disease, ocular tumors, ocular trauma, manifest strabismus, or any ocular condition affecting visual function.
  5. Systemic diseases associated with immunodeficiency or conditions considered by the investigator unsuitable for spectacle wear, such as diabetes, Down syndrome, rheumatoid arthritis, or psychiatric disorders.
  6. Participation in a drug clinical trial within the previous 3 months or a medical device clinical trial within the previous month.
  7. Meeting the inclusion criteria in only one eye.
  8. Inability to attend regular ophthalmic examinations.
  9. Participation in any myopia control clinical trial within the previous 3 months, or previous or current use of rigid contact lenses (including associated care products), multifocal contact lenses, progressive addition lenses or other specially designed myopia control spectacle lenses, or atropine.
  10. Deemed ineligible by the investigator.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Dual-Effect Myopia Control Lenses

Participants in this group will wear dual-effect myopia control spectacle lenses for 12 months, with a recommended daily wearing time of at least 12 hours.

Dual-effect myopia control spectacle lenses manufactured by Jiangsu Kangmeida Optical Co., Ltd. Participants will be advised to wear the spectacles for at least 12 hours per day for 12 months.

Active Comparator: Nikon Kongyoudian 2.0 Lenses

Participants in this group will wear Nikon Kongyoudian 2.0 spectacle lenses for 12 months, following the same wearing instructions as the experimental group.

Nikon Kongyoudian 2.0 spectacle lenses manufactured by Nikon Optical Co., Ltd. The lenses will be used in the same manner as the investigational lenses for 12 months.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change in Cycloplegic Spherical Equivalent Refraction at 12 Months
Time Frame: Baseline and 12 months (±30 days)

Change in spherical equivalent refraction (SER) from baseline to 12 months, measured by objective autorefraction under cycloplegia. SER is calculated as sphere power plus half the cylinder power, expressed in diopters (D).

Baseline and 12 months (±30 days)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change in Axial Length
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Change in axial length from baseline, measured before cycloplegia using optical biometry.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Change in Cycloplegic Spherical Equivalent Refraction at 6 Months
Time Frame: Baseline and 6 months (±30 days)

Change in spherical equivalent refraction (SER) from baseline to 6 months, measured by objective autorefraction under cycloplegia, expressed in diopters (D).

Baseline and 6 months (±30 days)
Visual Acuity With Study Spectacles
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Visual acuity measured while wearing the assigned study spectacles.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Change in Corneal Curvature
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Change in corneal curvature from baseline, measured before cycloplegia using optical biometry.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Change in Anterior Chamber Depth
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Change in anterior chamber depth from baseline, measured before cycloplegia using optical biometry.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Change in Lens Thickness
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Change in crystalline lens thickness from baseline, measured before cycloplegia using optical biometry.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Change in Subjective Refraction
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Change in subjective refraction from baseline, assessed before cycloplegia.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Best-Corrected Visual Acuity
Time Frame: 6 months (±30 days) and 12 months (±30 days)

Best-corrected visual acuity assessed using an ETDRS logMAR E chart.

6 months (±30 days) and 12 months (±30 days)
Change in Binocular Visual Function
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Change in binocular visual function from baseline, assessed at follow-up visits.

Baseline, 6 months (±30 days), and 12 months (±30 days)
Visual Questionnaire Score
Time Frame: 6 months (±30 days) and 12 months (±30 days)

Visual assessment using the Chinese version of the PRER2 questionnaire.

6 months (±30 days) and 12 months (±30 days)

Other Outcome Measures

Outcome Measure
Measure Description
Time Frame
Incidence of Adverse Events and Serious Adverse Events
Time Frame: Throughout the 12-month study period

Occurrence of symptoms, signs, complications, adverse events, and serious adverse events related to the study products or procedures.

Throughout the 12-month study period
Intraocular Pressure
Time Frame: 6 months (±30 days), and 12 months (±30 days)

Intraocular pressure measured using non-contact tonometry, expressed in mmHg.

6 months (±30 days), and 12 months (±30 days)
Fundus Examination Grade
Time Frame: 6 months (±30 days), and 12 months (±30 days)

Fundus findings assessed and graded according to the study protocol.

6 months (±30 days), and 12 months (±30 days)
Spectacle Frame Position Assessment
Time Frame: Baseline, 6 months (±30 days), and 12 months (±30 days)

Assessment of spectacle frame positioning and lens condition according to the study protocol.

Baseline, 6 months (±30 days), and 12 months (±30 days)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

December 1, 2026

Primary Completion (Estimated)

December 31, 2027

Study Completion (Estimated)

December 31, 2027

Study Registration Dates

First Submitted

November 8, 2026

First Submitted That Met QC Criteria

November 8, 2026

First Posted (Actual)

November 13, 2026

Study Record Updates

Last Update Posted (Actual)

November 13, 2026

Last Update Submitted That Met QC Criteria

November 8, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • 2026KYPJ157

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

Individual participant data will not be shared with external researchers.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.