- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT00609947
Endeavor Zotarolimus - Eluting Stent in the Treatment Lesions in Small Native Coronary Arteries. (ENDEAVORSVS)
A Clinical Evaluation of the Medtronic Endeavor Zotarolimus-Eluting Coronary Stent System in the Treatment of De Novo Lesions in Small Diameter Native Coronary Arteries
Study Overview
Status
Conditions
Intervention / Treatment
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
South Carolina
-
Anderson, South Carolina, United States, 29621
- AnMed Health Medical Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
GENERAL INCLUSION CRITERIA:
- The patient is ≥18 years of age.
- The patient has clinical evidence of ischemic heart disease, stable or unstable angina, silent ischemia, or positive functional study.
- The patient is an acceptable candidate for Percutaneous Transluminal Coronary Angiography (PTCA), stenting, and emergent Coronary Artery Bypass Grafting (CABG) surgery.
- Female patients of childbearing potential must have a negative pregnancy test within 7 days before the procedure.
- The patient or patient's legal representative has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board of the respective clinical site.
- The patient agrees to return to same research facility for all required post-procedure follow-up visits.
ANGIOGRAPHIC INCLUSION CRITERIA
1. The target lesion/vessel must meet the following criteria:
The patient requires treatment of either:
- A single de novo lesion located in a native coronary artery amenable to treatment with a 2.25mm, 2.5mm or 2.75mm stent, or
- Two de novo lesions located in separate target vessels, with at least one of the target lesions amenable to treatment with a 2.25mm, 2.5mm, or 2.75mm stent and the second lesion amenable to treatment with a 2.25mm, 2.5mm, or 2.75mm stent or a 3.0mm or 3.5mm approved Endeavor stent.
- The lesion(s) must be ≤ 27mm in length.
- The lesion(s) must have a stenosis of ≥ 50% and < 100%.
- The vessel(s) has (have) a thrombolysis in myocardial infarction (TIMI) flow 2 or greater.
- The target vessel reference diameter must be ≥ 2.25mm and ≤ 2.75mm and the second target vessel reference diameter, if present, must be ≥ 2.25mm and ≤ 3.5mm.
- All target lesions can be treated with a Medtronic Endeavor stent.
GENERAL EXCLUSION CRITERIA:
- Known hypersensitivity or contraindication to aspirin, heparin, bivalirudin, ticlopidine, clopidogrel, cobalt, nickel, chromium, molybdenum, polymer coatings, or sensitivity to contrast media, which cannot be adequately pre-medicated
- History of allergic reaction or significant sensitivity to drugs such as zotarolimus, rapamycin, tacrolimus, everolimus, or any other analogue or derivative
- Platelet count <100,000 cells/mm³ or >700,000 cells/mm³, or white blood cell count <3,000 cells/mm³
- Serum creatinine level >2.0 mg/dl within 7 days prior to index procedure
- Evidence of acute MI within 72 hours of intended index procedure
- Planned PCI of any vessel within 30 days pre or post-index procedure and/or planned PCI of the target vessel(s) within 12 months post-procedure.
- During the index procedure, the target lesion(s) requires treatment with a device other than PTCA prior to stent placement
- History of stroke or transient ischemic attack (TIA) within prior 6 months
- Active peptic ulcer or upper gastrointestinal (GI) bleeding within prior 6 months.
- History of bleeding diathesis or coagulopathy or patient will refuse blood transfusions.
- Concurrent medical condition with life expectancy of less than 12 months.
- Any previous or planned treatment of target vessel with anti-restenotic therapies including but not limited to brachytherapy.
- Currently participating in an investigational drug or another device study that has not completed primary endpoint or that clinically interferes with current study endpoints; or requires coronary angiography, IVUS or other coronary artery imaging procedures.
- Documented left ventricular ejection fraction (LVEF) <30% at most recent evaluation.
- Inability to comply with protocol required medication regimen ANGIOGRAPHIC EXCLUSION CRITERIA
1. Target lesion(s) located in native vessel distal to anastomosis with saphenous vein graft or a left/right internal mammary artery bypass with >40% diameter stenosis anywhere within graft.
2. Previous stenting in the target vessel(s) unless the following conditions are met:
a. It has been at least 9 months since the previous stenting, and b. The target lesion(s) is/are at least 15mm away from the previously placed stent.
3. Target vessel has other lesions with >40% diameter stenosis based on visual estimate or on-line QCA 4. Target vessel(s) has/have evidence of thrombus 5. Target vessel(s) is excessively tortuous (two bends ≥90º to reach target lesion) 6. Target lesion has any of the following characteristics:
- Location is aorto-ostial, an unprotected left main lesion, or within 5 mm of the origin of the left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA)
- Involves a side branch >2.0 mm in diameter
- Is at or distal to a >45º bend in the vessel
- Is severely calcified
- Involves a bifurcation 7. Unprotected left main coronary artery disease
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Endeavor Zotarolimus-Eluting Coronary Stent
Zotarolimus-eluting stent (ZES) implanted using standard percutaneous coronary intervention (PCI) technique via the femoral approach
|
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
In-segment Percent Diameter Stenosis at 8 Months Post-procedure
Time Frame: 8 months post-procedure
|
In-segment percent diameter stenosis at 8 months post-procedure with percent diameter stenosis defined as the value calculated as 100 x (RVD - Minimal Lumen Diameter (MLD)/RVD using the mean values from two orthogonal views (when possible) by Qualitative Coronary Angiography (QCA).
|
8 months post-procedure
|
|
Major Adverse Cardiac Events (MACE) Rate
Time Frame: 12 months post-procedure
|
Major Adverse Cardiac Events rate at 12 months post-procedure defined as death, target-vessel Myocardial Infarction (Q wave and non-Q wave), emergent cardiac bypass surgery, or target lesion revascularization, repeat percutaneous transluminal coronary angioplasty or cardiac bypass surgery.
|
12 months post-procedure
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Martin B Leon, MD, Columbia University
Study record dates
Study Major Dates
Study Start
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Estimate)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- IP057
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.