Effect of Prone Position on Liver Blood Flow and Function (PLiF)

December 1, 2015 updated by: University of Nottingham

The Effect of Prone Positioning During Anaesthesia on Liver Blood Flow and Function

Recent occurrence of significant post-operative liver impairment at Nottingham University Hospitals NHS Trust has prompted investigation into whether interaction between general anaesthesia and prone positioning (lying face down) for surgery can influence liver function.

Historical research has shown that the heart does not function as efficiently when an anaesthetised patient is placed in the prone position for surgery. The techniques used for anaesthetising and monitoring these patients have changed remarkably, since these studies were first performed.

It is important to know accurately how the heart functions to enable better understanding of the changes in blood flow to the liver when in the prone position.

Studies looking at blood flow to the liver when lying face down have been done before but are mainly reporting patients on the intensive care unit. These intensive care patients are different to those in theatre undergoing routine surgery. The intensive care patients are usually received in different types of drugs and monitored with several different types of monitor at the time. Perhaps most importantly is that they are placed face down on a soft air cushioned mattress and pillows rather than the rigid support used for surgical patients.

This study will look at whether the function of the liver changes when a patient is anaesthetised and is then rolled onto their front. The function of the liver will be measured by looking how it clears a specific drug from the blood. Also this study will look at how accurate a particular type of heart monitor is when an anaesthetised patient is placed onto their front.

Study Overview

Status

Unknown

Detailed Description

Recent occurrence of significant post-operative hepatic dysfunction including two fatalities at Nottingham University Hospitals NHS Trust has prompted investigation into whether interaction between general anaesthesia, prone positioning for surgery, cardiac output and the use of vasoactive drugs can influence hepatic function.

Research has shown that cardiac output is decreased when an anaesthetised patient is placed from the supine to the prone position, and that the magnitude of these changes vary with the exact method of physical patient support in the prone position.1-3 Anaesthetic technique and methods of cardiac output monitoring used in these studies are no longer in routine use and therefore may not accurately reflect current practice of balanced anaesthesia or current monitoring techniques.

The LiDCOplus minimally invasive cardiac output monitor can be used to accurately calculate cardiac ouput and its associated derived variables (stroke volume and systemic vascular resistance). The LiDCOplus monitor uses data already available from an arterial cannula which is routinely used for monitoring patients in these circumstances. It is calibrated by using a small (0.3mmol) bolus dose of lithium chloride. This technique has been shown to be accurate and safe even after repeated calibration procedures over a short time period.4-6

Much of the evidence with regards to liver blood flow in the anaesthetised patient in prone position is from the critical care literature. There are several differences between this group of critically ill patients undergoing prone positioning for rescue therapy from refractory hypoxia due to acute lung injury and healthy patients undergoing elective surgery in the prone position. Critically ill patients have multiple cardiovascular and respiratory co-morbidities, are usually receiving infusions of vasoactive drugs and are generally positioned on soft air cushioned mattresses and pillows. Prone positioning in these patients does not seem to significantly alter hepatic function as measured by hepatic Indocyanine Green (ICG) clearance.7 8

ICG is a fluorescent dye, which can absorb infra-red light with a very rare (1:40 000) side effect profile. After intravenous injection it is almost exclusively eliminated by hepatic excretion into bile. The rate of hepatic elimination has been shown to correlate accurately with plasma disappearance rate as measured by transcutaneous infra-red absorbtion.9 It is a dynamic marker of hepatic blood flow, hepatocellular function and biliary excretion, with short term variation thought to be attributable to changes in hepatic blood flow rather than cellular dysfunction.10

The LiMON monitor uses transcutaneous infra-red light absorption (like a pulse oximeter) to measure and calculate values for ICG plasma disappearance and its associated values such as clearance rate and plasma retention rate. The technique involves intravenous injection of a small (0.25mg/kg) bolus dose of ICG. This can be repeated up to 20 times per 24hr period.

It is postulated that simultaneously measuring changes in hepatic blood flow and cardiac output will allow us to gather greater understanding of the haemodynamic changes associated with the prone position in the anaesthetised patient using current routine monitoring modalities.

Study Type

Observational

Enrollment (Anticipated)

21

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Nottinghamshire
      • Nottingham, Nottinghamshire, United Kingdom, NG7 2UH
        • Recruiting
        • Queen's Medical Centre Campus, Nottingham University Hospitals NHS Trust.
        • Contact:
        • Sub-Investigator:
          • Marc Chikhani, BMedSci BMBS FRCA
        • Principal Investigator:
          • Iain Moppett, MB BChir MA MRCP FRCA DM

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 65 years (Adult, Older Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients between the age of 18-65, presenting for neurosurgical procedures to the Queen's Medical Centre, Nottingham, England, UK.

Description

Inclusion Criteria:

  • Adult patient
  • ASA (American Society of Anaesthesiologists) I/II
  • Surgery in prone position
  • Classification of surgery as minor / moderate severity

Exclusion Criteria:

  • Inability to give consent to inclusion in trial
  • Unable to speak or read English
  • Age less than 18 years
  • Age over 65 years
  • Pregnancy
  • Pre-existing hepatic dysfunction
  • Taking oral lithium (interferes with LiDCOplus calibration factor)
  • Severe valvular heart disease (reduced reliability of LiDCO measurements)
  • Major severity surgery with predicted large blood loss or alteration in aortic root anatomy
  • Intolerance including allergy to lithium, iodine or ICG
  • Thyrotoxicosis
  • Patients expected to require radio active iodine studies within one week of the study

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Young. Fit. Minor neurosurgical operation. Prone position.
18-65 year old patients, without serious medical co-morbidities (assessed as ASA I/II status) who are having minor to moderate severity neurosurgical operations in the prone position.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Liver blood flow and function as measured by non-invasive determination of ICG excretion.
Time Frame: During operative anaesthesia on day 1
To test the null hypothesis that hepatic blood flow or global hepatic function does not change in the prone position during anaesthesia and therefore the ICG elimination rate remains constant and is unaffected by anaesthesia or patient position.
During operative anaesthesia on day 1

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Validating LiDCO calibration between supine and prone positions
Time Frame: During operative anaesthesia on day 1 of study
To test the null hypothesis that calibration factor for the LiDCOplus monitor as determined by lithium dilution is not affected by changing the patient from supine to prone position.
During operative anaesthesia on day 1 of study
Evaluation of change in cardiac output on position change.
Time Frame: During surgical anaesthesia on day 1 of study
To test the null hypothesis that cardiovascular parameters as measured by the LiDCOplus monitor are not affected by changing the patient from supine to prone position.
During surgical anaesthesia on day 1 of study
Validation of preload predictors in the prone position.
Time Frame: During surgical anaesthesia on day 1 of study
To test the null hypothesis that the dynamic indices of preload retain their discriminatory ability to predict positive response following a fluid bolus when the patient is placed in the prone position.
During surgical anaesthesia on day 1 of study

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

May 1, 2014

Primary Completion (Anticipated)

May 1, 2016

Study Completion (Anticipated)

June 1, 2016

Study Registration Dates

First Submitted

January 29, 2013

First Submitted That Met QC Criteria

January 29, 2013

First Posted (Estimate)

January 31, 2013

Study Record Updates

Last Update Posted (Estimate)

December 2, 2015

Last Update Submitted That Met QC Criteria

December 1, 2015

Last Verified

December 1, 2015

More Information

Terms related to this study

Other Study ID Numbers

  • 12098

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Prone Position

3
Subscribe