Comparison of Bedside Ultrasound With Chest X-ray for Confirmation of Central Venous Catheter Position (COMBUX)

February 20, 2018 updated by: Jasper Smit, Amsterdam UMC, location VUmc

Comparison of Bedside Ultrasound With Chest X-ray to Detect CVC Related Mechanical Complications; a Prospective Observational Study (COMBUX-study)

Background:

Insertion of a central venous catheter (CVC) could lead to a variety of complications.

To detect those complications, Chest X-ray (CXR) is still the reference standard. However, there are major limitations in performing CXR's in the critical care setting.

Aim/objectives:

The objective of this study is to compare the use of bedside ultrasound (US) to conventional CXR in visualization of accuracy and safety of the CVC placement. The aim is to eventually replace X-ray with bedside ultrasound as gold standard for the confirmation of CVC-placement in critically ill patients, thereby reducing radiation exposure and unnecessary delay before CVC use.

Methods:

The bedside US will be performed by the student or attending physician, who is blinded for CXR findings. After US examination, the attending physician (or student) will fill in a structured form, based on an established protocol. CXR will be performed before or after US examination and assessed by a radiologist. The radiologist will be blinded for the findings of the bedside ultrasound to prevent any biases. Final diagnosis will be determined after examination of the complete medical chart.

Study Overview

Detailed Description

Most patients admitted to an intensive care unit undergo central venous catheterization (CVC) or already have received a CVC. Over 5 million CVC placements are performed each year in the United States. An indication of central venous access is for example when peripheral veins are inaccessible or for the administration of potent vasoactive drugs such as norepinephrine or dopamine. Three anatomical sites are frequently used to insert a CVC: the subclavian, jugular and femoral site. Although central venous catheterization offers multiple advantages, it is associated with adverse events that could be hazardous for patients. Mechanical, infectious or thrombotic complications could occur. Most common mechanical complications include arterial puncture, hematoma and pneumothorax. Besides mechanical complications, malposition of a CVC could also lead to complications, including phlebitis, perforation, and venous thrombosis or occlusion. Malposition of the CVC tip into the right atrium could also lead to arrhythmias. The frequency of primary mal-positioning has been shown to be up to 3.7%. A recent multicenter trial, which included 3471 catheters in 3027 patients, showed that subclavian-vein catheterization was associated with a lower risk of bloodstream infection and symptomatic thrombosis but involved a higher risk of pneumothorax as compared to jugular-vein or femoral-vein catheterization. The risk of mechanical complications in subclavian, jugular or femoral catheterization was 2.1%, 1.4% and 6% respectively.

To date, the post-procedural chest X-ray (CXR) has been the reference standard to detect these mechanical complications. Some studies suggest that it should not be considered a reliable procedure for detecting complications in the absence of clinical symptoms. In addition, reading of a bedside CXR alone is not very accurate to identify intra-atrial tip position. The exceedingly low complication rate after right internal jugular vein catheterization suggests that, to detect pneumothorax and intra-atrial malposition, routine post-procedure CXR is neither necessary nor accurate and causes delay until catheter use. Omitting the need for CXR could reduce healthcare costs as well.

Due to some clear advantages, there has already been an increasing role for ultrasonography in the critical care setting. In comparison to radiography, an advantage of ultrasound is that the patient is not exposed to radiation, and is often faster performed. Compared to the traditional 'blind' landmark method, ultrasound-guided subclavian cannulation reduces failed catheterizations and complications associated with subclavian catheterization. Advantages of ultrasound-guided cannulation include correct identification of the vein, detecting variable anatomy and reducing events of arterial puncture. Due to the developing knowledge and techniques in ultrasound, is has been suggested that it would be a suitable method to replace CXR in the role of detecting pneumothorax and identifying CVC tip position. A small number of studies already demonstrated this effect.

In this study we evaluate the use of ultrasound as diagnostic modality in patients after CVC placement in the subclavian or jugular vein. This research proposal aims to evaluate US examination as diagnostic tool for misplacement, bleeding and pneumothorax after CVC-placement. Combining the different strategies from previous studies. we developed "tHe UltraSound evaluation of Cvc Insertion" i.e. HUSCI-protocol. Hereby, we aim to improve accuracy The outcome measure will be the sensitivity and specificity of US. In addition, diagnostic concordance between US and CXR in patients after CVC placement will be studied. If US catches clinical relevant findings accurately we can replace standard expensive and harmful CXR as standard diagnostic tool in patients after CVC-placement in the future. We hypothesize that US can confirm correct CVC placement and detect potential associated complications accurately.

Study Type

Observational

Enrollment (Actual)

750

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Noord-Holland
      • Amsterdam, Noord-Holland, Netherlands, 1081 HZ
        • VU University Medical Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients who undergo central venous cannulation

Description

Inclusion Criteria:

  • Age above 18
  • Central venous cannulation performed
  • CVC in internal jugular vein or subclavian vein

Exclusion Criteria:

  • Refusal to undergo ultrasound examination
  • Refusal to undergo chest X-ray
  • CVC in femoral vein
  • PICC

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Diagnostic accuracy of ultrasound to detect CVC malposition
Time Frame: Accuracy will be measured after ultrasound and Chest X-ray evaluation (expected time frame: 3 hours)
Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) are used as accuracy outcome parameters. A 'true positive' result is defined as an US-suggested aberrant position of the CVC (catheter tip in any other vein than the superior vena cava (SVC), outside the venous system, or positioned deep in the right atrium or ventricle) confirmed by CXR. If bedside US rules out an aberrant position of the catheter tip correctly it is considered to be a 'true negative' result
Accuracy will be measured after ultrasound and Chest X-ray evaluation (expected time frame: 3 hours)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Feasibility of ultrasound
Time Frame: Feasiblity will be measured after ultrasound and Chest X-ray evaluation (expected time frame: 3 hours)
Ultrasound is considered to be feasible if all US-views in the protocol can be obtained
Feasiblity will be measured after ultrasound and Chest X-ray evaluation (expected time frame: 3 hours)
Diagnostic accuracy of ultrasound to detect pneumothorax
Time Frame: Accuracy will be measured after ultrasound and Chest X-ray evaluation (expected time frame: 3 hours)
Interobserver and overall percent agreement between US and CXR is calculated
Accuracy will be measured after ultrasound and Chest X-ray evaluation (expected time frame: 3 hours)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

June 1, 2016

Primary Completion (ACTUAL)

December 1, 2017

Study Completion (ACTUAL)

December 1, 2017

Study Registration Dates

First Submitted

November 4, 2016

First Submitted That Met QC Criteria

November 4, 2016

First Posted (ESTIMATE)

November 9, 2016

Study Record Updates

Last Update Posted (ACTUAL)

February 22, 2018

Last Update Submitted That Met QC Criteria

February 20, 2018

Last Verified

February 1, 2018

More Information

Terms related to this study

Other Study ID Numbers

  • 2016.053

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe