Keratoconus is a progressive corneal degeneration characterized by progressive steepening and thinning of the central or paracentral cornea leading to corneal protrusion and resulting irregular astigmatism and high myopia. This disorder is usually bilateral and is linked to atopy and excessive eye rubbing, although the precise pathophysiology behind development of this condition is unclear. Keratoconus is the most common corneal degeneration in the United States, affecting between 50 and 230 subjects per 100,000 population.
Early diagnosis and appropriate management of keratoconus relies greatly on accurate assessment of corneal topographic measurements. It is therefore imperative that the data obtained via corneal topography devices is accurate and reliable.
The GALILEI Dual Scheimpflug Analyzer integrates Placido disc topography and dual Scheimpflug tomography to assess anterior and posterior corneal curvature data. Although there have been several studies performed assessing the ability of the Galilei to accurately distinguish keratoconus from unaffected eyes and investigating interdevice reliability between the Galilei analyzer and other tomographers, to our knowledge the repeatability of measurements obtained in this population via the Galilei device has been incompletely evaluated to date.
Corneal topography data obtained via the Galilei device is relied upon heavily in clinical decision making for keratoconic patients both in the Hershey Eye Clinic and in a great number of ophthalmology practices world-wide. It is vital that the accuracy and repeatability of these measurements obtained via the Galilei device are investigated.
The primary endpoint to be measured in the study will be the maximum (steepest) and minimum (flattest) keratometry values in the central zone.
Secondary endpoints will be maximum keratometry across the entire area scanned, axis of corneal astigmatism, anterior and posterior best fit spheres in float mode with the diameter set to 8 mm, maximum anterior and posterior elevations, thinnest corneal thickness, and corneal asphericity at 6 mm, root mean square (RMS) of the HOAs, RMS of the third-order coma, coma axis, vertical and horizontal coma and spherical aberration.
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
Pennsylvania
-
Hershey, Pennsylvania, United States, 17033
- Penn State Hershey Eye Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patientswho are older than 18 years of age
- Patients who are scheduled to undergo Galilei dual-scheimpflug corneal topography testing
- Patients who have been diagnosed with keratoconus
- Measurements with a reported reliability of 'good' from the topographer
Exclusion Criteria:
- Patients who have undergone any prior surgical intervention involving the cornea (i.e. cornea transplant or INTACS, or corneal cross linking)
Study Plan
How is the study designed?
Design Details
- Observational Models: Case-Only
- Time Perspectives: Cross-Sectional
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
Keratoconic Patients
|
A series of five measurements via the Galilei corneal topographer of each keratoconic eye in quick succession
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Maximum (steepest) and minimum (flattest) keratometry values in the central zone
Time Frame: Measured at day 0 of study enrollment
|
Assessment of the steepness of the cornea
|
Measured at day 0 of study enrollment
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Thinnest pachymetry
Time Frame: Measured at day 0 of study enrollment
|
The thinnest area of the cornea
|
Measured at day 0 of study enrollment
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Seth Pantanelli, MD, Milton S. Hershey Medical Center
Publications and helpful links
General Publications
- Rabinowitz YS. Keratoconus. Surv Ophthalmol. 1998 Jan-Feb;42(4):297-319. doi: 10.1016/s0039-6257(97)00119-7.
- Bawazeer AM, Hodge WG, Lorimer B. Atopy and keratoconus: a multivariate analysis. Br J Ophthalmol. 2000 Aug;84(8):834-6. doi: 10.1136/bjo.84.8.834.
- Demir S, Sonmez B, Yeter V, Ortak H. Comparison of normal and keratoconic corneas by Galilei Dual-Scheimpflug Analyzer. Cont Lens Anterior Eye. 2013 Oct;36(5):219-25. doi: 10.1016/j.clae.2013.04.001. Epub 2013 Apr 30.
- Holladay JT. Keratoconus detection using corneal topography. J Refract Surg. 2009 Oct;25(10 Suppl):S958-62. doi: 10.3928/1081597X-20090915-11.
- Guler E, Yagci R, Akyol M, Arslanyilmaz Z, Balci M, Hepsen IF. Repeatability and reproducibility of Galilei measurements in normal keratoconic and postrefractive corneas. Cont Lens Anterior Eye. 2014 Oct;37(5):331-6. doi: 10.1016/j.clae.2014.04.004. Epub 2014 Jun 14.
- Meyer JJ, Gokul A, Vellara HR, Prime Z, McGhee CN. Repeatability and Agreement of Orbscan II, Pentacam HR, and Galilei Tomography Systems in Corneas With Keratoconus. Am J Ophthalmol. 2017 Mar;175:122-128. doi: 10.1016/j.ajo.2016.12.003. Epub 2016 Dec 18.
- Feizi S, Yaseri M, Kheiri B. Predictive Ability of Galilei to Distinguish Subclinical Keratoconus and Keratoconus from Normal Corneas. J Ophthalmic Vis Res. 2016 Jan-Mar;11(1):8-16. doi: 10.4103/2008-322X.180707.
- Jahadi Hosseini HR, Katbab A, Khalili MR, Abtahi MB. Comparison of corneal thickness measurements using Galilei, HR Pentacam, and ultrasound. Cornea. 2010 Oct;29(10):1091-5. doi: 10.1097/ICO.0b013e3181cf98e5.
- Anayol MA, Guler E, Yagci R, Sekeroglu MA, Ylmazoglu M, Trhs H, Kulak AE, Ylmazbas P. Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using galilei, Pentacam, and Sirius devices. Cornea. 2014 Jun;33(6):582-6. doi: 10.1097/ICO.0000000000000119.
- Park SH, Choi SK, Lee D, Jun EJ, Kim JH. Corneal thickness measurement using Orbscan, Pentacam, Galilei, and ultrasound in normal and post-femtosecond laser in situ keratomileusis eyes. Cornea. 2012 Sep;31(9):978-82. doi: 10.1097/ICO.0b013e31823d03fc.
- Crawford AZ, Patel DV, McGhee CN. Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems. Am J Ophthalmol. 2013 Jul;156(1):53-60. doi: 10.1016/j.ajo.2013.01.029. Epub 2013 Mar 28.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- STUDY00007951
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.