- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT03524248
Development of Real-time Image-guided Radiotherapy
February 27, 2020 updated by: Fox Chase Cancer Center
The goal is to achieve the maximal radiotherapy tumor dose while sparing the health tissue and critical structures.
On-board cone-beam CT (CBCT) scans are routinely acquired prior to dose delivery and matched with simulation CT at the planned treatment positions.
Thus, setup or motion errors can be detected and corrected.
However, CBCT is not available for situations with gantry collisions such as WBI and TSEB.
More importantly, CBCT cannot reveal any irregular respiration or body movement during beam-on time.
Thus, it is essential to develop a real-time image system that can detect organ/body motion during beam-on time, and correlate simulation-planning images with prior treatment CBCT images.In this proposed clinical trial, we will cooperate with a 3D camera company (Xigen LLC) to develop novel 4D video imaging techniques and validate the feasibility and accuracy of 4D video image guidance in correlation with 4D CT/CBCT useful for advanced IGRT.
Study Overview
Status
Terminated
Conditions
Intervention / Treatment
Study Type
Interventional
Enrollment (Actual)
159
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
Pennsylvania
-
Philadelphia, Pennsylvania, United States, 19140
- Temple University Hospital
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
18 years and older (Adult, Older Adult)
Accepts Healthy Volunteers
No
Genders Eligible for Study
All
Description
Inclusion Criteria:
- All patients benefit from advanced IGRT can participate to the study except for those emergent and pediatric patients (age <18 years) who require special care or there is no time for the setup the 4D video systems
- The patient population would be selected according to the technical progress and clinical needs
Exclusion Criteria:
- None
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Develop real-time 4D video imaging guidance with combination use of cone-beam computerized tomography (CBCT) useful for daily setup and target motion tracking in advanced image-guided radiotherapy (IGRT).
Time Frame: 12 years
|
Real time 4-D video imaging in combination with CBCT to detect appropriate delivery of radiotherapy
|
12 years
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To correlate real-time 4D surface images with the internal structures shown in daily XVI volumetric images
Time Frame: 12 years
|
Align 4D surface images with internal structures
|
12 years
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To synchronize the 4D CBCT with real-time stereovisions that would allow us to track any irregular respiration motion useful for gated or target tracked radiotherapy
Time Frame: 12 years
|
Synchronization of 4D CBCT with real time stereovision
|
12 years
|
|
To validate accuracy and precision of the patient position in special procedures such as stereotactic body radiotherapy (SBRT), total skin electron beam therapy (TSEB), IMRT of H&N cancer, and whole-breast irradiation (WBI) under breast holding
Time Frame: 12 years
|
Validation
|
12 years
|
|
To determine delivery dose distribution by correlating real-time surface images with the planning volumetric images and dose distribution for radiotherapy
Time Frame: 12 years
|
Determine delivery dose distribution at the site or radiotherapy
|
12 years
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (Actual)
May 17, 2012
Primary Completion (Actual)
July 16, 2018
Study Completion (Actual)
July 19, 2018
Study Registration Dates
First Submitted
May 2, 2018
First Submitted That Met QC Criteria
May 2, 2018
First Posted (Actual)
May 14, 2018
Study Record Updates
Last Update Posted (Actual)
March 2, 2020
Last Update Submitted That Met QC Criteria
February 27, 2020
Last Verified
February 1, 2020
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 16-6006
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
No
product manufactured in and exported from the U.S.
No
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.