- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05497206
ROSA® Hip System THA PMCF
A Post-Market, Multi-Center, Single Arm Trial on Robotic Instrumentation (ROSA® Hip System) in Patients Undergoing Direct Anterior Total Hip Arthroplasty With Fluoroscopic Guidance
Study Overview
Status
Conditions
Detailed Description
Consecutive patients who meet all of the inclusion criteria and none of the exclusion criteria will be eligible for participation in the study, and will be pre-screened for participation in the informed consent process.
The primary objective of this study is to assess the accuracy of acetabular implant position by evaluating the percentage of participants who are within the range of the Callanan safe zones for Acetabular Inclination (30 - 45 degrees). A patient is considered a success if their intra-operative and/or post-operative full pelvis fluoroscopic or radiographic images show the postoperative acetabular inclination to be within this safe zone range.
Secondary Objectives include the evaluation of safety and efficacy of this system and will include the assessment of common adverse events, physical exam findings, radiologic results, and patient reported outcome measures.
Data collection will occur at the following intervals: Pre-operative, Operative, 3-months, 1-year, and 2-years. Enrollment for the study is anticipated to last approximately 18 months. Allowing for 24 months of follow-up, the total estimated study time to final-patient final-visit will be approximately 42 months.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Florida
-
Jacksonville, Florida, United States, 32224
- The Mayo Clinic Jacksonville
-
-
Missouri
-
Saint Joseph, Missouri, United States, 64507
- Mosaic Life Care
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion:
- Age 18 - 80 years
- Body mass index ≤40 (BMI = kg/m2)
- Patient is willing and able to provide informed consent
- Patient qualifies for primary THA, via an anterior approach, due to osteoarthritis or avascular necrosis of the hip based on Investigator's clinical judgment
- Independent of study participation, patient is a candidate and meets the indications and none of the contraindications for use with the ROSA Hip System
Exclusion:
- Has undergone an orthopaedic procedure of the spine or lower extremity, or is currently participating in a pain management clinical study of any joint, within the last 6 months or planned within the next 6 months
- Patients receiving simultaneous bilateral hip arthroplasties are excluded from participation in this study; as well as any participants with staged bilateral arthroplasties within 6 months of each other
- Active infection, sepsis, osteomyelitis
- Patient is at a high risk for dislocation including those with long-segment spinal fusions (>3 levels) and neuromuscular disorders
- Inflammatory (rheumatoid or psoriatic arthritis) or post-traumatic arthropathy, or any other degenerative joint disease not consistent with osteoarthritis
- Would, in the Investigator's opinion, be unwilling or unable to comply with the postoperative follow-up schedule
- Patient is considered a member of a vulnerable population (pregnant, prisoner, mentally incompetent, etc.)
- Previous hardware in the proximal femur or acetabulum from a prior orthopaedic procedure
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Robotic-Assisted THA
Consecutive participants will receive THA via the ROSA Hip System.
|
Total Hip Arthroplasty
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy of implant position
Time Frame: 90 days
|
To evaluate the accuracy of acetabular implant position using the robotic-arm surgical assistant (ROSA® Hip System) (rTHA).
Accuracy of acetabular implant position will be assessed by evaluating the percentage of participants who are within the range of the Callanan safe zones for Acetabular Inclination (30 - 45 degrees).
A patient is considered a success if their intra-operative and/or post-operative full pelvis fluoroscopic or radiographic images show the postoperative acetabular inclination to be within this safe zone range.
|
90 days
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of Patient safety
Time Frame: 24 months
|
Frequency and incidence of adverse events, serious adverse events, adverse device effects, serious adverse device effects, and unanticipated serious adverse device effects as well as device deficiencies.
|
24 months
|
|
Patient Reported Outcome Measure (Oxford Hip Score)
Time Frame: 24 months
|
A questionnaire completed by the patient consisting of twelve questions that utilize a 5-point Likert scoring system (0 - 4) resulting in a score ranging from 0 (worst) to 48 (best).
|
24 months
|
|
Numeric Pain Rating Scale (NPRS)
Time Frame: 24 months
|
An 11-point NPRS is a patient self-completed reported outcome and will be used to assess the current level of pain for the affected hip.
On this scale, 0 will indicate no pain and 10 will indicate the worst pain imaginable
|
24 months
|
|
Subject Satisfaction
Time Frame: 24 months
|
A questionnaire consisting of a single satisfaction question in regard to the subjects hip replacement.
Answers will include the following: Very Dissatisfied, Dissatisfied, Neutral, Satisfied, Very Satisfied.
|
24 months
|
|
Clinical performance will be assessed with evaluation of range of motion.
Time Frame: 24 months
|
Range of motion will be evaluated in a supine position and assess flexion, abduction (in flexion), adduction (in flexion), external rotation (in extension), and internal rotation (in extension).
Range of motion will be measured in degrees.
|
24 months
|
|
Clinical performance will be assessed with evaluation of stability using the Trendelenburg test.
Time Frame: 24 months
|
The test is negative when the hip of the leg that is lifted, will also go up i.e., hiking of hip or the pelvis tilts upwards.
The test is positive, when there is a drop of the hip or a downwards tilt of the pelvis.
The test is level when the subject presents normal gait and adequate pelvic stability.
If the subject is unable to perform the test, this will be noted "unable to perform test".
|
24 months
|
|
Clinical performance will be assessed by testing leg length discrepancy.
Time Frame: 24 months
|
This will be assessed by (3) categories (legs equal, right short, left short) and discrepancies will be measured in mm or cm.
|
24 months
|
|
Physician Radiographic Assessment of Acetabular Cup
Time Frame: 2 Years
|
Records acetabular cup inclination (degrees), acetabular cup anteversion (degrees)
|
2 Years
|
|
Physician Radiographic Assessment of Femoral and Global Offset and Leg Length Discrepancy
Time Frame: 2 Years
|
Records femoral offset (mm), global offset (mm), leg length (mm)
|
2 Years
|
|
Physician Radiographic Assessment of Significant Radiographic Findings
Time Frame: 2 Years
|
Records evidence of fracture (y/n), evidence of acetabular migration (y/n), evidence of heterotopic ossification (y/n), or other significant radiographic findings (including the zone it occurs in)
|
2 Years
|
Collaborators and Investigators
Sponsor
Investigators
- Study Director: Hillary Overholser, Zimmer Biomet
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- CMU2021-26TDS
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Osteoarthritis, Hip
-
Poznan University of Medical SciencesRecruitingHip Pain Chronic | Hip Osteoarthritis | Hip ArthropathyPoland
-
University of MiamiNot yet recruiting
-
Poznan University of Medical SciencesRecruiting
-
Tulip MedicineCompletedRehabilitation | Hip Osteoarthritis | Hip Arthroplasty Replacement | Hip Arthroplasty, TotalKazakhstan
-
Poznan University of Medical SciencesNot yet recruitingHip Osteoarthritis | Arthropathy of HipPoland
-
Poznan University of Medical SciencesRecruitingHip Pain Chronic | Hip OsteoarthritisPoland
-
Poznan University of Medical SciencesNot yet recruitingHip Osteoarthritis | Arthropathy of HipPoland
-
Istituto Ortopedico RizzoliCompleted
-
Poznan University of Medical SciencesNot yet recruitingHip Osteoarthritis
-
Artvin Coruh UniversityCompletedHip OsteoarthritisTurkey (Türkiye)
Clinical Trials on One of the following hip implants may be used within this arm of the study: G7 Acetabular System, Taperloc Complete System, Avenir and Avenir Complete Systems, and Echo Bi-Metric System
-
Hip Innovation TechnologyRecruitingOsteoarthritis, Hip | Avascular Necrosis of Hip | Degenerative Joint Disease | Traumatic Arthropathy-HipUnited States