Neuromuscular Electrical Stimulation on Humeral Adductors in Subjects With Rotator Cuff Tear: an Observational Study
Humeral and Scapular Kinematics Correction in Patients With Full-thickness Rotator Cuff Tear: Co-contraction Patterns and Muscle Training, Novel Brace With Neuromuscular Electrical Stimulation
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Participants Based on the pilot study, a sample size of 30 patients is calculated to provide 80% power with an effect size of 0.5 (acromiohumeral distance difference = 0.9 mm with and without NMES). Rotator cuff tear subjects will be recruited from the Department of Orthopedic surgery or Department of Physical Medicine and Rehabilitation at National Taiwan University Hospital (NTUH). All subjects will be provided written informed consent before inclusion in the experiment. The study is approved by the NTUH Institutional Review Board.
Instrumentation Three-dimensional electromagnetic motion tracking system The Polhemus 3Space FASTRAK® (Polhemus Inc., Colchester, VT, US), an electromagnetic motion analysis system with MotionMonitor software (Innovative Sports Training, Inc., Chicago, IL, US), will be used to track and collect three-dimensional scapular kinematics. Three sensors are attached to the flat bony surface of the acromion and the sternum with adhesive tape, and to the distal humerus between the lateral and medial epicondyles via Velcro straps with adhesive tape (Figure 1). The other sensors are attached by a stylus to digitalize the 3-dimensional positions on bony landmarks including the sternal notch, xiphoid process, C7 vertebrae, T8 vertebrae, T12 vertebrae, anterior and posterior glenohumeral joint, acromioclavicular joint, root of the spine of the scapula, inferior angle of the scapula, and lateral and medial epicondyles to build the shoulder complex model. Each receiver will be sampled at the rate of 120 updates/second divided by the number of sensors.
Ultrasonography (USG) measurements The BenQ T3300 Tablet Ultrasound System (BenQ Medical Technology Corp., Taipei, Taiwan) with a L154BH linear array 4-15MHz broadband transducer will be used for non-invasive evaluation of AHD in 3 actively abducted positions (at 0°, 60°, and 90° of shoulder abduction). Real-time imaging will be performed with rapid B-mode scanning to generate images with the following settings: gain, 66-68; dynamic range, 75; persistence, 3; QScan, 4, for sharpness and smoothing; gray map, 3; Chroma 0; steer angle, 0; and transducer, 5.5 MHz. The minimum measurement distance of this USG is 1 mm with error less than ± 5%.
Neuromuscular Electrical Stimulation (NMES) The GM300TE COMBO NMES (Gemore Technology Co., Ltd., New Taipei City, Taiwan), a portable machine with dual controllable channels and a manual switch, will be applied to the PM and TM. According to a previous study, muscle force generation is modulated by stimulated frequency, pulse width, and intensity. It linearly increases with stimulated amplitude and pulse duration. The electronics of the unit creates the electrical impulses with an output frequency of 50 Hz and a pulse width of 300 microseconds. The synchronous (S) mode and asymmetrical rectangular wave-pulse are used throughout the experiment. The amplitude is set as muscle motor-level contraction with self-perception of maximal tolerable intensity. The time of tetanic stimulation is 7 seconds with 20-second intervals between stimulations to avoid muscle fatigue. The two circular electrodes are used on each adductor to minimize the stimulated interference with the nearby muscles.
Surface electromyography (sEMG) Muscle activation will be collected at 1000 Hz/channel with the resolution of a 16-bit A/D converter to 16-bit D/A analog converter (Model MP 150, Biopac Systems Inc., Aero Camino Goleta, CA, USA). The system includes pairs of silver chloride circular electrodes (diameter: 10 mm; Ludlow Company LP, Chicopee, MA) with an interelectrode distance of 20 mm (center to center). The collected signals are amplified with a Grass AC/DC amplifier (Model 15A12, Astro-Med Inc., West Warwick, RI, USA) with gain of 1000 dB, a common-mode rejection ratio (CMRR) of 86 dB at 60 Hz, and a bandwidth (-3 dB) of 10 to 1000 Hz. Full bandwidth data (captured by the data acquisition and analysis systems software, AcqKnowledge, Biopac, Aero Camino Goleta, CA) are reduced using a root mean square (RMS) algorithm to produce envelopes with an effective sampling rate of 50 samples per second. The mean of the three trials for each task are calculated for data analysis.
Force measurement system The force-sensitive measurement system (FlexiForce ELFTM, New Taipei City, Taiwan) combines three single-point FlexiForce B201 sensors, one handle containing USB-interface electronics, and Windows-compatible software. Three circular sensors (diameter 9.53 mm; thickness 0.203 mm) are able to detect the range of force as low (4.4-111 N), medium (111-667 N) and high (667-4448 N) levels, respectively. This ensures that the various forces during maximal voluntary isometric contraction can be measured by the appropriate sensor. When the sensor detects the force, the software displays a histogram, curve graph, or number of the force detected as the real-time bio-feedback. The sampling rate of the data collection is set at 200 Hz.
Procedures Male subjects are asked to remove their shirts, and female subjects are asked to wear an open-backed bathing suit throughout the experiment. The subjects are asked to do the isometric abducted and adducted maximal isometric contraction test against the force sensors on the customized iron-ring, respectively. The maximum force is simultaneously recorded as the mean value during the isometric maximal isometric contraction tasks. Then acromiohumeral distance is assessed by USG probe in 3 abducted positions (resting position, 60° and 90°) with a custom-designed dynamic goniometer surrounding the distal part of the humerus. The USG probe is applied parallelly to the humerus shaft and over the anterior aspect of the anterior acromial margin. Three images are required for each position. Twenty-second intervals between each image prevents muscle fatigue. Following the USD imaging, sEMG electrodes are placed on the teres major and pectoralis major after the area is wiped clean with alcohol and scrubbed to reduce the impedance of the skin. After placement of the electrodes, the subject hang his/her arm in a neutral sitting posture with a force measurement sensor contacting the wrist. Each subject performs five trials of the isometric abduction and adduction task respectively at 60% of maximal force based on real-time force value feedback.
After that, the scapular kinematics during arm elevation are measured by FASTRAK in 5 trials. First, a physical therapist attachs the sensors to build the local coordinate system for the shoulder. Then the operator asks the subject to elevate the arm to ensure the angle was over 90° and to retract the scapula to confirm the axial direction of scapular internal/external rotation displayed on the system. Second, the subjects are instructed to elevate the arm as high as possible at a comfortable speed within 3 seconds and then slowly to lower the arm to the starting position. An audible metronome set to 1 Hz is used as the cue during the elevation task.
All subjects are asked to perform the same assessment with NMES. The order of NMES application to the teres major or pectoralis major will be randomized. All the optimal NMES attachments are confirmed with the recruiting activity by the motor point pen. Subsequently, the maximal tolerable intensity is ensured and recorded in the three abducted positions. Then the scapular kinematics during arm elevation and the acromiohumeral distance measurements in specific arm positions are performed during NMES on one of the target adductors. Subjects are asked to hold the specific arm position with NMES for at least 3 seconds in each trial during the acromiohumeral distance measurement. In addition, the NMES is sustained for at least 7 seconds during the scapular kinematic tracking during arm elevation. After a 10-minute break following the assessments, NMES on another adductor muscle is conducted. Following the NMES stimulation, subjects performs the co-contraction assessment immediately. The muscle activity data in both isometric abduction and adduction are immediately collected pre- and post-NMES. Then the data of the scapular kinematics during arm elevation and the acromiohumeral distance at resting position and at 60° and 90° of shoulder abduction are analyzed.
Statistical analysis Data will be analyzed in Statistical Package for the Social Sciences (SPSS), version 22 (International Business Machines Corp., New York, USA). The Shapiro-Wilk test is used to test for normality. With normal distribution, two-way ANOVAs (3 conditions x 3 positions for acromiohumeral distance measurements and 3 conditions x 6 positions of scapular kinematics) will be used. The alpha level is set at 0.05 with two-tailed testing. Without normal distribution, a nonparametric test (Friedman test) is used for data analysis. Co-contraction ratios between baseline and immediately post-NMES are compared by t test or Wilcoxon signed-rank test whether or not distribution is normal.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: jiu jenq lin, PhD
- Phone Number: 33668126
- Email: jiujlin@ntu.edu.tw
Study Locations
-
-
-
Taipei, Taiwan
- Recruiting
- School of Physical Therapy, National Taiwan University
-
Contact:
- jiu jenq lin, PhD
- Phone Number: 33668126
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Study Population
Description
Inclusion Criteria:
- between 20 to 85 years old
- diagnosed with symptomatic rotator cuff tear based on ultrasonography or magnetic resonance imaging
- pain or discomfort specific to the shoulder.
Exclusion Criteria:
- a diagnosis of frozen shoulder or adhesion capsulitis
- glenohumeral joint instability
- a history of affected shoulder surgery or traumatic dislocation/fracture over the past year
- symptoms related to the cervical spine in recent 6 months
- neuromuscular diseases, such as polymyositis and myotonic dystrophy
- limited arm elevation less than 90°
- contraindications for NMES.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Quadruple
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: novel brace with neuromuscular electrical stimulation plus exercise group
The experimental group received additional NMES during exercise.
According to a previous study, the unit's electronics created electrical impulses with an output frequency of 80 Hz and a duration of 200 ms.
The synchronous (S) mode and asymmetrical rectangular wave-pulse were used throughout the experiment.
The amplitude was set as muscle motor-level contraction with the self-perception of maximal tolerable intensity.
A rise and fall time of 2s with a tetanic muscle stimulation lasting 8 seconds and a 3s duration between stimulations were used for all participants.
|
The symptomatic rotator cuff tear subjects had NMES on scapular muscles and adductor muscle
Other Names:
|
|
Active Comparator: exercise control group
The exercise intervention consisted of scapular-focused exercises with theraband, including scapula row, serratus punch, and adduction exercises in a standing position.
The scapula row exercise was performed with the arm straight and the shoulder flexed to 30°.
Participants retracted their scapula and brought the theraband to the side of the body, then returned; the serratus punch exercise began with elbow flexion at 90° and held the theraband.
Participants punched and protracted their scapula; the adduction exercise was conducted with arm straight, shoulder internal rotation, and abduction at 30°.
Participants pull the theraband to the side of the body.
Each was performed at 10 repetitions per set for 3 sets daily.
|
The symptomatic rotator cuff tear subjects conduct scapular and adductor exercise
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
acromiohumeral distance
Time Frame: change from baseline to "during the neuromuscular electrical stimulation"
|
acromiohumeral distance was measured by ultrasonography
|
change from baseline to "during the neuromuscular electrical stimulation"
|
|
scapular kinematics
Time Frame: change from baseline to "immediately after the neuromuscular electrical stimulation"
|
scapular kinematics during arm elevation with a three-dimensional motion tracking system.
|
change from baseline to "immediately after the neuromuscular electrical stimulation"
|
Collaborators and Investigators
Investigators
- Principal Investigator: jiu jenq lin, PhD, School of Physical Therapy, College of Medicine, National Taiwan University
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 202012082RINB
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Rotator Cuff Tears
-
Xiros LtdRecruitingRotator Cuff Tear | Rotator Cuff Injuries | Rotator Cuff Tears | Rotator Cuff Tears of the ShoulderUnited Kingdom
-
ZuriMED Technologies Inc.RecruitingRotator Cuff Tear | Rotator Cuff Tears | Rotator Cuff Tears of the ShoulderUnited States
-
Gazi UniversityActive, not recruitingMassive Irreparable Rotator Cuff TearsTurkey (Türkiye)
-
BAAT Medical Products B.V.Active, not recruiting
-
Parc de Salut MarHospital Clinic of Barcelona; Hospital Universitario Fundación Jiménez Díaz; Hospital... and other collaboratorsActive, not recruitingShoulder Disease | Massive Rotator Cuff TearsSpain
-
Atreon OrthopedicsCompletedRotator Cuff Tears | Full-thickness Rotator Cuff TearsUnited States
-
Anika Therapeutics, Inc.RecruitingRotator Cuff Tears of the ShoulderUnited States
-
Sohag UniversityActive, not recruitingRotator Cuff Tears of the ShoulderEgypt
-
BAAT Medical Products B.V.Recruiting
-
University of UtahEnrolling by invitationStudying the Genetic Relationship of Rotator Cuff TearsUnited States
Clinical Trials on novel brace with neuromuscular electrical stimulation
-
Federal University of Health Science of Porto AlegreRecruitingAnterior Cruciate Ligament Reconstruction | Anterior Cruciate Ligament Reconstruction RehabilitationBrazil
-
Shalamar Institute of Health SciencesNot yet recruiting
-
University of Illinois at ChicagoRecruitingStroke, Ischemic | Stroke Hemorrhagic | Stroke, CerebrovascularUnited States
-
Lahore University of Biological and Applied SciencesRecruitingStroke | Cerebro-vascular AccidentPakistan
-
Hitit UniversityRecruitingQuality of Life | AnxietyTurkey
-
Necmettin Erbakan UniversityCompletedCerebral Palsy (CP)Turkey (Türkiye)
-
University Hospital, BrestCompletedAsthma | Chronic Obstructive Pulmonary Disease Overlap SyndromeFrance
-
Brooks RehabilitationTerminatedBlepharoptosis | LagophthalmosUnited States
-
Hacettepe UniversityCompleted
-
St Mary's University CollegeNot yet recruitingAtrophy, Muscular | Atrophy, Disuse