Benefit of the SALAD Technique on CPR Quality During Intubation in Contaminated Airway

May 19, 2024 updated by: Shin Kong Wu Ho-Su Memorial Hospital
Management of airways in contaminated environments can compromise the quality of cardiopulmonary resuscitation (CPR). This study examined the effectiveness of SALAD (Suction Assisted Laryngoscopy Airway Decontamination) compared to intermittent suction in maintaining CPR quality during intubation in a simulated scenario of regurgitation. Following 2.5 hours of training in the SALAD technique, 36 emergency medicaltechnician-paramedics (EMT-Ps) were randomly assigned in equal numbers to two groups: one utilizing the SALAD technique and the other employing intermittent suction during intubation on a manikin. The manikin simulates regurgitation of gastric contents into the oropharynx during CPR. Primary outcomes assessed were CPR quality metrics, such as chest compression rate, depth, and interruption. Secondary outcomes included the success rate and time of intubation.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

The study was conducted in March 2024. Participants were emergency medical technician-paramedics (EMT-Ps) employed by fire departments across Taiwan, recruited on a nationwide basis. All participants provided signed informed consent forms. 36 EMT-Ps are involved in this study.

Simulation setup :

The CPR-induced regurgitation model was adapted from an Airway Larry Airway Management Trainer Torso (Nasco, Fort Atkinson, WI, USA) to simulate oropharyngeal regurgitation during CPR. To emulate the stomach, a manual pump was attached at the base of the manikin's torso. A transparent vinyl tube connected the manikin's esophagus to the pump's outlet port. A HQCPR device was used for CPR quality record.

Training program The 36 participants received 2.5 hours of SALAD training. The training included 5 rounds of intubation teaching and practice. The first two rounds of training involve using the SALAD technique with the video laryngoscope, while the third round used the C-MAC S video laryngoscope as a direct laryngoscope for practice. Technique adjustments can be made during the initial three rounds through monitoring with the video system. The fourth round will involve intubation using a direct laryngoscope with a size 3 Macintosh blade on the SALAD Simulator. The final round involved intubation on the CPR-induced regurgitation model, using a direct laryngoscope and employing the SALAD technique for intubation during chest compressions.

Simulation protocol After completing 2.5 hours of training, participants were randomly assigned to one of two groups for suction techniques: SALAD or intermittent suction. Randomization was conducted using the simple randomization method with a random number table. Participants assigned to the same suction technique group formed a resuscitation team, taking on roles as the airway manager, first chest compressor, or second chest compressor. Each participant rotated through these three roles during three simulation sessions.In each simulation, the airway manager was responsible for BVM ventilation and intubation. The first and second chest compressors performed chest compressions alternately, once every five CPR cycles, adhering to a 30:2 compression-to- ventilation ratio. The initial 30 chest compressions were followed by two ventilations, and suction was not performed during this phase, even if regurgitation was present. This was intended to simulate a scenario where the oral cavity was filled with regurgitant material during intubation, maintaining consistency across participants. After the first two ventilations, intubation could proceed while the team continued chest compressions. The airway manager could request a temporary reduction, lightening, or even cessation of chest compressions to facilitate intubation, or to continue up to 60 compressions without interruption if necessary. If the intubation attempt was unsuccessful, the airway manager had to administer two BVM ventilations before attempting intubation again. Depending on the group assignment, either SALAD or intermittent suction techniques were employed to assist in airway decontamination. After intubation, the airway manager assessed lung expansion using the BVM to verify successful intubation. A failed intubation was defined as any esophageal intubation or three unsuccessful intubation attempts. Each simulation concluded following either a successful or failed intubation.

Measurement The primary outcomes were CPR quality metrics, including chest compression rate, chest compression depth, and time of interruption. The secondary outcomes were the intubation success rate and intubation time. The rate and depth of the first 30 chest compressions (pre-intubation period) were measured. After the initial 30 compressions, interruptions for ventilation or airway management, as well as the quality of chest compressions during intubation, were also measured (intubation period). An intubation attempt was defined as the insertion of the laryngoscope blade into the mouth and its subsequent withdrawal during an unsuccessful attempt, or as the insertion of the laryngoscope blade followed by confirmation from the airway manager that the tube was inserted. Intubation time was defined as the period between the start and the end of an intubation attempt. Two video cameras were set up to record the entire simulation process. Two observers reviewed the video records independently to identify any intubation attempts. Disagreements were resolved by reaching a mutual consensus.

The HQCPR application on an Android device recorded chest compression depth, rate, and interruptions (defined as no chest compression for more than 1 second).

The data from both the video recordings and the HQCPR application were used in subsequent analyses.

Statistical analysis The characteristics of EMT-Ps were described using frequency and percentage for categorical variables, while mean values with standard deviation (SD) were used for continuous variables. Continuous data were compared using the independent t-test between the SALAD and intermittent suction groups, while categorical data were compared using the Fisher's exact test or the Chi-Squared test between these two groups. CPR quality metrics and intubation time were summarized using mean values with 95% confidence intervals (CI). Compression depth greater than or equal to 5 cm, first-pass intubation success, and esophageal intubation were presented as frequency and percentage. Continuous data were compared using the independent t test between the SALAD and intermittent suction groups, while categorical data were compared using Fisher's exact test between these two groups. CPR quality metrics between the pre-intubation period and the intubation period were analyzed using the paired t test in both the SALAD and intermittent suction groups. A two- tailed p-value of less than 0.05 indicated statistical significance. All data analyses and sample size determination were performed using MedCalc Statistical Software version 22.023 (MedCalc Software, Ostend, Belgium).

Study Type

Interventional

Enrollment (Actual)

36

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Shih-Lin
      • Taipei, Shih-Lin, Taiwan, 111
        • Shinkong Wu-Ho-Su memorial hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Child
  • Adult
  • Older Adult

Accepts Healthy Volunteers

Yes

Description

Inclusion Criteria:

  • emergency medical technician-paramedics experienced in advanced airway management and CPR

Exclusion Criteria:

  • N/A

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Health Services Research
  • Allocation: Non-Randomized
  • Interventional Model: Crossover Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
No Intervention: intermittent suction
intermittent suction during intubation
Experimental: SALAD
SALAD suction during intubation
SALAD suction during intubation

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
chest compression fraction
Time Frame: 3 hour
the proportion of time spent performing chest compressions during arrest
3 hour

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
success rate of intubation
Time Frame: 3 hour
the rate of successful intubation
3 hour

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Helpful Links

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 1, 2024

Primary Completion (Actual)

March 31, 2024

Study Completion (Actual)

March 31, 2024

Study Registration Dates

First Submitted

May 12, 2024

First Submitted That Met QC Criteria

May 19, 2024

First Posted (Actual)

May 24, 2024

Study Record Updates

Last Update Posted (Actual)

May 24, 2024

Last Update Submitted That Met QC Criteria

May 19, 2024

Last Verified

May 1, 2024

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Airway Aspiration

Clinical Trials on SALAD intubation

Subscribe