LMA Protector vs I-Gel in Low-Flow Anesthesia for Laparoscopic Cholecystectomy
Comparison of LMA Protector and I-Gel Use in Low-Flow Anesthesia for Laparoscopic Cholecystectomy: A Prospective Randomized Study
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Istanbul, Turecko (Türkiye), 34752
- Fatih Sultan Mehmet Training and Research Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Popis
Inclusion Criteria:
- Patients aged 18-65 years
- American Society of Anesthesiologists (ASA) physical status I or II
- Scheduled for elective laparoscopic cholecystectomy
Exclusion Criteria:
- Known or predicted difficult airway or history of difficult intubation
- Body Mass Index (BMI) greater than 35 kg/m²
- High risk of gastroesophageal reflux or aspiration
- Severe cardiac, respiratory, renal, or hepatic disease
- Pregnancy
- Patient refusal to participate
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Singl
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Group I: I-Gel
Patients managed with the I-Gel supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of i-gel supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Ostatní jména:
|
|
Experimentální: Group P: LMA Protector
Patients managed with the LMA Protector supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of LMA Protector supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Dynamic Lung Compliance (Cdyn)
Časové okno: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Dynamic compliance of the respiratory system, calculated automatically by the ventilator as tidal volume divided by (peak inspiratory pressure minus positive end-expiratory pressure).
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Peak Inspiratory Pressure (PIP)
Časové okno: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Maximum airway pressure generated during the inspiratory phase, monitored to assess airway dynamics under general anesthesia.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Plateau Pressure (Pplateau)
Časové okno: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Pressure applied to the small airways and alveoli during a period of zero gas flow, monitored to assess risk of barotrauma.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Airway Resistance
Časové okno: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
The resistance of the respiratory tract to airflow during mechanical ventilation, calculated using peak and plateau pressures.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Spolupracovníci
Spolupracovníci
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- FSM KAEK-2020/79
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .