LMA Protector vs I-Gel in Low-Flow Anesthesia for Laparoscopic Cholecystectomy
Comparison of LMA Protector and I-Gel Use in Low-Flow Anesthesia for Laparoscopic Cholecystectomy: A Prospective Randomized Study
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Istanbul, Turcja (Türkiye), 34752
- Fatih Sultan Mehmet Training and Research Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Patients aged 18-65 years
- American Society of Anesthesiologists (ASA) physical status I or II
- Scheduled for elective laparoscopic cholecystectomy
Exclusion Criteria:
- Known or predicted difficult airway or history of difficult intubation
- Body Mass Index (BMI) greater than 35 kg/m²
- High risk of gastroesophageal reflux or aspiration
- Severe cardiac, respiratory, renal, or hepatic disease
- Pregnancy
- Patient refusal to participate
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Pojedynczy
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: Group I: I-Gel
Patients managed with the I-Gel supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of i-gel supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Inne nazwy:
|
|
Eksperymentalny: Group P: LMA Protector
Patients managed with the LMA Protector supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of LMA Protector supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Dynamic Lung Compliance (Cdyn)
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Dynamic compliance of the respiratory system, calculated automatically by the ventilator as tidal volume divided by (peak inspiratory pressure minus positive end-expiratory pressure).
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Peak Inspiratory Pressure (PIP)
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Maximum airway pressure generated during the inspiratory phase, monitored to assess airway dynamics under general anesthesia.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Plateau Pressure (Pplateau)
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Pressure applied to the small airways and alveoli during a period of zero gas flow, monitored to assess risk of barotrauma.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Airway Resistance
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
The resistance of the respiratory tract to airflow during mechanical ventilation, calculated using peak and plateau pressures.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Współpracownicy i badacze
Sponsor
Sponsor
Współpracownicy
Współpracownicy
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- FSM KAEK-2020/79
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .