Investigational Scan (MRI) u pacientů s nově diagnostikovaným nebo recidivujícím thymomem
Může MRI nahradit CT při hodnocení thymomu?
This trial studies the accuracy of a magnetic resonance imaging (MRI) scan in imaging the inside of the chest in patients with thymoma that is newly diagnosed or has come back. An MRI scan may be able to detect if and how far the tumor has spread more accurately than a standard computed tomography (CT) scan.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Detailní popis
PRIMARY OBJECTIVES:
I. To determine whether thymoma staging by MRI is as accurate as staging by CT as compared to surgical staging.
SECONDARY OBJECTIVES:
I. To determine whether evaluation of phrenic nerve paralysis by functional MRI is as accurate as the fluoroscopic "sniff test" as compared to surgical evaluation of phrenic nerve involvement.
II. To determine whether fast novel MRI sequences are as accurate as conventional MRI sequences for staging thymoma, when comparing to surgical staging.
OUTLINE:
Patients undergo an MRI scan over 45-60 minutes and a diaphragm fluoroscopy 30 days before surgery.
Typ studie
Zápis (Odhadovaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Texas
-
Houston, Texas, Spojené státy, 77030
- M D Anderson Cancer Center
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- All adult patients scheduled to meet with a thoracic surgeon from MD Anderson Cancer Center (ACC) for resection of newly diagnosed thymoma or thymoma recurrence in the chest and scheduled for surgery
Exclusion Criteria:
- Children, defined as individuals younger than 18 years old on the preoperative visit with the thoracic surgeon
- Pregnant patients
- Patients unable to understand the consent form
- Patients with metal within the chest and pacemakers
- Patients with a known allergic reaction to gadolinium, who will have their MRI performed without contrast
- Patients with glomerular filtration rate (GFR) < 60 ml/min, who will have their MRI performed without contrast
- Patients with an allergy to iodinated contrast material will follow departmental routine policy, that is those with anaphylaxis will have their CT performed without intravenous contrast and others will be prepped as for departmental guidelines for routine chest CT
- Patients with abnormal renal function will have their CT study perform as per DI's iodinated contrast administration guidelines, and no contrast will be administered with GFR lower than 30 ml/min
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Diagnostic (MRI, diaphragm fluoroscopy)
Patients undergo an MRI scan over 45-60 minutes and a diaphragm fluoroscopy 30 days before surgery. |
Undergo MRI
Ostatní jména:
Undergo diaphragm fluoroscopy
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Accuracy of magnetic resonance imaging (MRI) staging
Časové okno: Up to 10 years
|
Will be compared to staging done by computed tomography (CT). McNemar's test will be used to compare the accuracy for the following five sets of comparisons: spin echo (SE) T1 compared versus (vs.) liver acquisition with volume acquisition (LAVA)+ in-phase (IP)/out-of-phase (OP), Dixon versus fast spin echo (FSE) T2, LAVA+IP/OP+Dixon vs. SET1+FSET2, LAVA+IP/OP+Dixon vs. computed tomography (CT) scan, and SET1+FSET2 vs. CT scan. A p value less than 0.05 will be defined as significant. A p value less than 0.05 will be defined as significant. |
Up to 10 years
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Accuracy of phrenic nerve paralysis by functional MRI
Časové okno: Up to 10 years
|
Will be evaluated against the fluoroscopic "sniff test" and compared to surgical evaluation of phrenic nerve involvement. The outcome is the binary indicator of whether the phrenic nerve is involved. The accuracy rate will be calculated for each of the three tested methods. And the method with the highest accuracy will be compared with the method with the medium accuracy and the method with least accuracy separately, using McNemar's test. |
Up to 10 years
|
|
Accuracy of fast novel MRI sequences
Časové okno: Up to 10 years
|
Will be evaluated against conventional MRI sequences for staging thymoma when compared to surgical staging. Will use the pathological stages as gold standard and calculate accuracy for the new shorter MRI sequences and current MRI sequences methods. Accuracy will be compared between two MRI techniques using McNemar's test. And the following five sets of comparisons will be tested: SE T1 compared vs. LAVA+ IP/OP, Dixon versus FSE T2, LAVA+IP/OP+Dixon vs. SET1+FSET2, LAVA+IP/OP+Dixon vs. CT scan, and SET1+FSET2 vs. CT scan. A p value less than 0.05 will be defined as significant. |
Up to 10 years
|
Spolupracovníci a vyšetřovatelé
Sponzor
Spolupracovníci
Vyšetřovatelé
- Vrchní vyšetřovatel: Marcelo F Benveniste, M.D. Anderson Cancer Center
Publikace a užitečné odkazy
Užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- 2011-0360
- P30CA016672 (Grant/smlouva NIH USA)
- 2011-0360 (Jiný identifikátor: M D Anderson Cancer Center)
- NCI-2019-02643 (Identifikátor registru: CTRP (Clinical Trial Reporting Program))
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .