Una scansione investigativa (MRI) nell'imaging di pazienti con timoma di nuova diagnosi o ricorrente
La risonanza magnetica può sostituire la TC nella valutazione del timoma?
This trial studies the accuracy of a magnetic resonance imaging (MRI) scan in imaging the inside of the chest in patients with thymoma that is newly diagnosed or has come back. An MRI scan may be able to detect if and how far the tumor has spread more accurately than a standard computed tomography (CT) scan.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
PRIMARY OBJECTIVES:
I. To determine whether thymoma staging by MRI is as accurate as staging by CT as compared to surgical staging.
SECONDARY OBJECTIVES:
I. To determine whether evaluation of phrenic nerve paralysis by functional MRI is as accurate as the fluoroscopic "sniff test" as compared to surgical evaluation of phrenic nerve involvement.
II. To determine whether fast novel MRI sequences are as accurate as conventional MRI sequences for staging thymoma, when comparing to surgical staging.
OUTLINE:
Patients undergo an MRI scan over 45-60 minutes and a diaphragm fluoroscopy 30 days before surgery.
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Texas
-
Houston, Texas, Stati Uniti, 77030
- M D Anderson Cancer Center
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- All adult patients scheduled to meet with a thoracic surgeon from MD Anderson Cancer Center (ACC) for resection of newly diagnosed thymoma or thymoma recurrence in the chest and scheduled for surgery
Exclusion Criteria:
- Children, defined as individuals younger than 18 years old on the preoperative visit with the thoracic surgeon
- Pregnant patients
- Patients unable to understand the consent form
- Patients with metal within the chest and pacemakers
- Patients with a known allergic reaction to gadolinium, who will have their MRI performed without contrast
- Patients with glomerular filtration rate (GFR) < 60 ml/min, who will have their MRI performed without contrast
- Patients with an allergy to iodinated contrast material will follow departmental routine policy, that is those with anaphylaxis will have their CT performed without intravenous contrast and others will be prepped as for departmental guidelines for routine chest CT
- Patients with abnormal renal function will have their CT study perform as per DI's iodinated contrast administration guidelines, and no contrast will be administered with GFR lower than 30 ml/min
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Diagnostic (MRI, diaphragm fluoroscopy)
Patients undergo an MRI scan over 45-60 minutes and a diaphragm fluoroscopy 30 days before surgery. |
Undergo MRI
Altri nomi:
Undergo diaphragm fluoroscopy
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Accuracy of magnetic resonance imaging (MRI) staging
Lasso di tempo: Up to 10 years
|
Will be compared to staging done by computed tomography (CT). McNemar's test will be used to compare the accuracy for the following five sets of comparisons: spin echo (SE) T1 compared versus (vs.) liver acquisition with volume acquisition (LAVA)+ in-phase (IP)/out-of-phase (OP), Dixon versus fast spin echo (FSE) T2, LAVA+IP/OP+Dixon vs. SET1+FSET2, LAVA+IP/OP+Dixon vs. computed tomography (CT) scan, and SET1+FSET2 vs. CT scan. A p value less than 0.05 will be defined as significant. A p value less than 0.05 will be defined as significant. |
Up to 10 years
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Accuracy of phrenic nerve paralysis by functional MRI
Lasso di tempo: Up to 10 years
|
Will be evaluated against the fluoroscopic "sniff test" and compared to surgical evaluation of phrenic nerve involvement. The outcome is the binary indicator of whether the phrenic nerve is involved. The accuracy rate will be calculated for each of the three tested methods. And the method with the highest accuracy will be compared with the method with the medium accuracy and the method with least accuracy separately, using McNemar's test. |
Up to 10 years
|
|
Accuracy of fast novel MRI sequences
Lasso di tempo: Up to 10 years
|
Will be evaluated against conventional MRI sequences for staging thymoma when compared to surgical staging. Will use the pathological stages as gold standard and calculate accuracy for the new shorter MRI sequences and current MRI sequences methods. Accuracy will be compared between two MRI techniques using McNemar's test. And the following five sets of comparisons will be tested: SE T1 compared vs. LAVA+ IP/OP, Dixon versus FSE T2, LAVA+IP/OP+Dixon vs. SET1+FSET2, LAVA+IP/OP+Dixon vs. CT scan, and SET1+FSET2 vs. CT scan. A p value less than 0.05 will be defined as significant. |
Up to 10 years
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: Marcelo F Benveniste, M.D. Anderson Cancer Center
Pubblicazioni e link utili
Collegamenti utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 2011-0360
- P30CA016672 (Sovvenzione/contratto NIH degli Stati Uniti)
- 2011-0360 (Altro identificatore: M D Anderson Cancer Center)
- NCI-2019-02643 (Identificatore di registro: CTRP (Clinical Trial Reporting Program))
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .