Suture vs Staples for Skin Closure After Liver Resection
A Randomised Controlled Trial to Compare Subcuticular Suture vs Staples for Skin Closure After Liver Resection.
Closure of the skin after liver resection (surgery to remove part of the liver) may be achieved by one of several methods. The standard method at our institution is to use stainless steel staples to adjoin the two sides of skin. Alternatively, a continuous absorbable suture may be used to "sew" the skin together.
The ideal method of closure should be safe, effective, associated with minimal patient discomfort and have a good cosmetic result. At present, there is no scientific evidence to describe which method is most suitable following liver resection.
The primary aims of this study is to investigate which method (subcuticular sutures vs staples) offers the best result in postoperative rate of (1) skin infection, (2) skin dehiscience (separation of skin) and (3) time taken to perform skin closure. In addition, we are interested in which method is best for patient satisfaction and cosmetic appearance and which method is most cost effective.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
-
Leeds, Det Forenede Kongerige, LS9 7TF
- Leeds Teaching Hospital NHS Trust
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- All patients undergoing liver resection surgery for benign or malignant aetiology
- All patients undergoing surgery as a living liver donor.
Exclusion Criteria:
- Any patient with an active wound infection
- Any patient with an active incisional wound hernia from previous surgery
- Synchronous bowel/liver surgery
- History of keloid formation
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Andet: Staple Group
Staple Group: At the end of the operation, the skin will be closed using stainless steel staples, which is standard clinical practice at St. James's University Hospital.
Approximately ten days after the operation, the staples will be manually removed; this is normally performed by the patients GP.
|
|
|
Eksperimentel: Suture Group
Suture Group: At the end of the operation, the skin will be closed using absorbable surgical suture.
Manual removal of this suture is not required because the thread is self-absorbable.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Post-operative infection time
Tidsramme: 1 year
|
1 year
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Time taken for skin closure
Tidsramme: 12 months
|
12 months
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- GS13/10722
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .