Suture vs Staples for Skin Closure After Liver Resection
A Randomised Controlled Trial to Compare Subcuticular Suture vs Staples for Skin Closure After Liver Resection.
Closure of the skin after liver resection (surgery to remove part of the liver) may be achieved by one of several methods. The standard method at our institution is to use stainless steel staples to adjoin the two sides of skin. Alternatively, a continuous absorbable suture may be used to "sew" the skin together.
The ideal method of closure should be safe, effective, associated with minimal patient discomfort and have a good cosmetic result. At present, there is no scientific evidence to describe which method is most suitable following liver resection.
The primary aims of this study is to investigate which method (subcuticular sutures vs staples) offers the best result in postoperative rate of (1) skin infection, (2) skin dehiscience (separation of skin) and (3) time taken to perform skin closure. In addition, we are interested in which method is best for patient satisfaction and cosmetic appearance and which method is most cost effective.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Leeds, Reino Unido, LS9 7TF
- Leeds Teaching Hospital NHS Trust
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- All patients undergoing liver resection surgery for benign or malignant aetiology
- All patients undergoing surgery as a living liver donor.
Exclusion Criteria:
- Any patient with an active wound infection
- Any patient with an active incisional wound hernia from previous surgery
- Synchronous bowel/liver surgery
- History of keloid formation
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Otro: Staple Group
Staple Group: At the end of the operation, the skin will be closed using stainless steel staples, which is standard clinical practice at St. James's University Hospital.
Approximately ten days after the operation, the staples will be manually removed; this is normally performed by the patients GP.
|
|
|
Experimental: Suture Group
Suture Group: At the end of the operation, the skin will be closed using absorbable surgical suture.
Manual removal of this suture is not required because the thread is self-absorbable.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Post-operative infection time
Periodo de tiempo: 1 year
|
1 year
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Time taken for skin closure
Periodo de tiempo: 12 months
|
12 months
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
Otros números de identificación del estudio
- GS13/10722
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .