Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

En undersøgelsesscanning (MRI med Dixon-baserede sekvenser) til påvisning af prostatakræft

5. oktober 2026 opdateret af: M.D. Anderson Cancer Center

Evaluering af MR med Dixon-baserede sekvenser til påvisning af prostatacancer

This trial studies the use of magnetic resonance imaging (MRI) with Dixon based imaging sequences in detecting prostate cancer. MRI uses radio waves and a powerful magnet linked to a computer to create detailed pictures of areas inside the body. Researchers hope to learn if using a modified MRI scan technique with Dixon based imaging sequencing will help to produce better images of prostate cancer than the standard of care MRI scan technique.

Studieoversigt

Status

Aktiv, ikke rekrutterende

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

PRIMARY OBJECTIVES:

I. Evaluate prospectively the accuracy of Dixon based sequences in detection of intraprostatic tumor nodules.

II. Determine the sensitivity, specificity, positive and negative predictive value of Dixon based sequences in assessment of extraprostatic tumor extension and lymph node involvement.

SECONDARY OBJECTIVES:

I. Compare the accuracy of Dixon based sequences versus multiparametric diffusion weighted imaging including diffusion tensor imaging in tumor detection and extraprostatic extension.

II. Compare the accuracy of Dixon based sequences in detection of transition zone tumors.

III. Determine the optimal scanning parameters for Dixon based sequences in the imaging of prostate adenocarcinoma.

OUTLINE:

Patients undergo MRI with additional Dixon based sequences with fat and water over a total of 49 minutes.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

65

Fase

  • Tidlig fase 1

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Texas
      • Houston, Texas, Forenede Stater, 77030
        • M D Anderson Cancer Center

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Han

Beskrivelse

Inclusion Criteria:

  • Biopsy proven prostate cancer patients who are scheduled to undergo prostatectomy.
  • Patient who is scheduled to have a clinically indicated staging endorectal prostate MRI exam.
  • Patients who have signed their informed consent form to undergo the study.

Exclusion Criteria:

  • Known prior hormone ablation or radiation therapy (pelvic or prostate).
  • Patients who do not want to undergo prostatectomy and prefer other therapy or surveillance.
  • Contraindication to conventional MR imaging (e. g. metal implants, pace maker, etc.).

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Diagnostic (standard MRI, Dixon MRI)

Patients undergo MRI with additional Dixon based sequences with fat and water over a total of 49 minutes.

Undergo Dixon MRI

Andre navne:
  • Dixon Fat-Suppression MRI

Undergo standard MRI

Andre navne:
  • MR
  • Magnetisk resonansbilledscanning
  • Medicinsk billeddannelse, magnetisk resonans / kernemagnetisk resonans
  • MR billeddannelse
  • MR-scanning
  • NMR billeddannelse
  • NMRI
  • Kernemagnetisk resonansbilleddannelse

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Detection of at least one or more prostate lesions with Dixon sequencing
Tidsramme: through study completion, an average of 1 year

Will evaluate and compare the accuracy of Dixon based sequencing to the conventional T2 weighted sequencing for detection of intraprostatic tumor and extraprostatic tumor extension. Lesions will be within any of six regions of the prostate: left apex, left mid, left base, right apex, right mid, and right base. The relative sensitivity and specificity of the two sequencing methods will be compared using an adjusted McNemar's test for clustered data where clusters consist of the matched pairs of within patient-zone observations. The primary analysis will also provide 95% confidence intervals for marginal sensitivity and specificity using a generalized linear mixed model.

through study completion, an average of 1 year

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Samarbejdspartnere

Efterforskere

  • Ledende efterforsker: Ganeshan Dhakshina Moorthy, M.D. Anderson Cancer Center

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

25. april 2013

Primær færdiggørelse (Anslået)

2. februar 2027

Studieafslutning (Anslået)

2. februar 2027

Datoer for studieregistrering

Først indsendt

8. september 2021

Først indsendt, der opfyldte QC-kriterier

8. september 2021

Først opslået (Faktiske)

17. september 2021

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

6. oktober 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

5. oktober 2026

Sidst verificeret

1. oktober 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • 2012-0003
  • 2012-0003 (Anden identifikator: M D Anderson Cancer Center)
  • NCI-2019-02461 (Registry Identifier: CTRP (Clinical Trial Reporting Program))

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .