Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials
Quantitative Clinical Evaluation of the Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials:a Self-control Study
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Fujian
-
Fuzhou, Fujian, Kina, 350004
- Fujian Medical University
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- with one mandibular first molar requiring crown restoration that have undergone root canal treatment;
- with complete permanent dentition;
Exclusion Criteria:
- with carious lesions, abrasions, attrition, erosions or any kind of tooth defects;
- with any kind of restorations in occlusal surfaces;
- with any sign of temporomandibular dysfunction.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Ikke-randomiseret
- Interventionel model: Crossover opgave
- Maskning: Dobbelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: Zirconia
10 crowns made of zirconia from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
Eksperimentel: Celtra Duo
10 crowns made of Celtra Duo from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
Eksperimentel: e.max CAD
10 crowns made of e.max CAD from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
Eksperimentel: Lici UPCERA
10 crowns made of Lici from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
Eksperimentel: Enamic
10 crowns made of Enamic from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
Eksperimentel: Runci UPCERA
10 crowns made of Runci from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
milling trueness(μm)
Tidsramme: 1 week
|
the absolute 3D deviation of occlusal contact points before and after milling
|
1 week
|
|
postprocessing trueness(μm)
Tidsramme: 1 week
|
the absolute 3D deviation of occlusal contact points before and after postprocessing
|
1 week
|
|
clinical trueness(μm)
Tidsramme: 1 week
|
the absolute 3D deviation of occlusal contact points before and after occlusal adjustment
|
1 week
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Efterforskere
Efterforskere
- Ledende efterforsker: Hao Yu, Fujian Medical University
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 2019028
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .