Real-World Validation of Huawei Wearable Technologies for Hypertension Risk Screening in Malaysia (Huawei-SunU1)
Background:
Hypertension (high blood pressure) is a major risk factor for heart disease and stroke, yet many people do not know they have it. In Malaysia, nearly half of all adults with elevated blood pressure are unaware of their condition. Standard clinic blood pressure checks can miss cases of high blood pressure or falsely flag temporary stress-related spikes. While 24-hour Ambulatory Blood Pressure Monitoring (ABPM) is the standard method for an accurate diagnosis, it is not practical for large-scale screening.
Purpose:
The purpose of this study is to evaluate whether a novel Huawei smartwatch, which uses photoplethysmography (PPG) technology to estimate blood pressure, can accurately identify individuals at high risk for hypertension in a real-world setting.
Study Design & Procedures:
Participants: Approximately 500 adults will be enrolled over a 24-month study period.
Screening: All participants will use the Huawei smartwatch screening tool to monitor their blood pressure estimates.
Validation: A subgroup of approximately 50 participants identified as high-risk by the smartwatch will undergo 24-hour ABPM (the clinical gold standard) to confirm whether they have high blood pressure.
Goal:
Researchers aim to validate the accuracy of the smartwatch screening tool against 24-hour ABPM to determine if wearable technology can support early detection and timely treatment of undiagnosed hypertension in the community.
Studieoversigt
Status
Status
Betingelser
Betingelser
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Kontakter og lokationer
Studiekontakt
Studiekontakt
- Navn: Yook Chin Chia
- Telefonnummer: +60374918622
- E-mail: ycchia@sunway.edu.my
Undersøgelse Kontakt Backup
- Navn: Yee How Say
- Telefonnummer: +60374918622
- E-mail: yeehows@sunway.edu.my
Studiesteder
-
-
Selangor
-
Subang Jaya, Selangor, Malaysia, 47500
- Faculty of Medical and Life Sciences, Sunway University
-
Kontakt:
- Yook Chin Chia
- Telefonnummer: +60374918622
- E-mail: ycchia@sunway.edu.my
-
Kontakt:
- Yee How Say
- Telefonnummer: +60374918622
- E-mail: yeehows@sunway.edu.my
-
Ledende efterforsker:
- Yook Chin Chia
-
Ledende efterforsker:
- Yee How Say
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
- Possesses the specific Huawei wearable required for the study
- Aged ≥18 years
- Malaysian citizen/permanent resident
- Understands English, Malay, or Chinese
- Able to download the required application on a compatible smartphone
- Willing to wear devices continuously
- Able to provide informed consent.
Exclusion Criteria:
- Current pregnancy
- Implantable cardiac devices (e.g., permanent pacemakers, implantable cardioverter-defibrillators [ICDs])
- Uncontrolled arrhythmias (e.g., active atrial fibrillation, frequent premature ventricular contractions [PVCs])
- Movement disorders or active tremors that interfere with signal acquisition (e.g., severe Parkinson's disease, essential tremor)
- Acute medical conditions, including:
- Acute coronary syndromes (e.g., recent myocardial infarction or unstable angina within the past 3 months)
- Acute cerebrovascular events (e.g., stroke or transient ischemic attack [TIA] within the past 3 months)
- Acute decompensated heart failure or severe respiratory distress
- Active, severe acute infections or systemic inflammatory illness (e.g., sepsis, acute pneumonia)
- Hypertensive emergencies or urgency
- Currently on antihypertensive medications
- Resting BP ≥180/110 mmHg.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Antal grupper/kohorter
Kohorter og interventioner
Gruppe / kohorteGruppe / kohorte |
|---|
|
Screening Population
Adults enrolled in the community screening phase who undergo non-invasive blood pressure estimation using the Huawei PPG smartwatch over the 24-month study period.
|
|
High-Risk Validation Cohort
A targeted subset of participants (n = 50) identified as high-risk for hypertension by the Huawei smartwatch screening tool, who undergo 24-hour Ambulatory Blood Pressure Monitoring (ABPM) to confirm their diagnostic status.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Diagnostic Accuracy (AUC-ROC) of the Huawei PPG Smartwatch Hypertension Risk Algorithm Compared to 24-Hour Ambulatory Blood Pressure Monitoring (ABPM)
Tidsramme: Month 11 through Month 18.
|
Measure Description: Area Under the Receiver Operating Characteristic Curve (AUC-ROC) evaluated by comparing the binary high-risk classification flags generated by the Huawei PPG smartwatch algorithm directly against diagnostic confirmation from clinical 24-hour ABPM. Unit of Measure: Score on a scale from 0.0 to 1.0 (where 0.5 represents chance performance and 1.0 represents perfect discrimination) |
Month 11 through Month 18.
|
|
Diagnostic Sensitivity of the Huawei PPG Smartwatch Hypertension Risk Algorithm
Tidsramme: Month 11 through Month 18.
|
Measure Description: The proportion of participants with true ABPM-confirmed hypertension who are correctly identified as high-risk by the Huawei PPG smartwatch algorithm. Unit of Measure: Percentage of true positive cases |
Month 11 through Month 18.
|
|
Diagnostic Specificity of the Huawei PPG Smartwatch Hypertension Risk Algorithm
Tidsramme: Month 11 through Month 18.
|
Measure Description: The proportion of participants without ABPM-confirmed hypertension who are correctly identified as low-risk by the Huawei PPG smartwatch algorithm. Unit of Measure: Percentage of true negative cases |
Month 11 through Month 18.
|
|
Positive Predictive Value (PPV) of the Huawei PPG Smartwatch Hypertension Risk Algorithm
Tidsramme: Month 11 through Month 18
|
Measure Description: The probability that a participant flagged as high-risk by the Huawei PPG smartwatch algorithm actually has hypertension confirmed by 24-hour ABPM. Unit of Measure: Percentage |
Month 11 through Month 18
|
|
Negative Predictive Value (NPV) of the Huawei PPG Smartwatch Hypertension Risk Algorithm
Tidsramme: Month 11 through Month 18
|
Measure Description: The probability that a participant flagged as low-risk by the Huawei PPG smartwatch algorithm actually does not have hypertension confirmed by 24-hour ABPM. Unit of Measure: Percentage |
Month 11 through Month 18
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Participant Adherence to Huawei Wearable Monitoring Protocols
Tidsramme: Month 1 through Month 12 (up to 12 months per participant)
|
Measure Description: The proportion of enrolled participants who achieve minimum complete wearable datasets, defined as continuous daily wear of the Huawei smartwatch to track PPG, heart rate, physical activity, and sleep metrics. Unit of Measure: Percentage of enrolled participants |
Month 1 through Month 12 (up to 12 months per participant)
|
|
Participant Usability and Acceptance Score Measured via Post-Monitoring Questionnaire
Tidsramme: At the completion of the wearable monitoring phase (Month 12).
|
Measure Description: Total score evaluating participant satisfaction, device comfort, and acceptance of the Huawei wearable for hypertension screening, measured using a standardized post-monitoring user experience questionnaire.
Unit of Measure: Mean score on a 1 to 5 Likert scale (where 1 = Strongly Disagree/Poor and 5 = Strongly Agree/Excellent)
|
At the completion of the wearable monitoring phase (Month 12).
|
Andre resultatmål
Andre resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Prevalence of Wearable-Identified High-Risk Flags in the Study Population
Tidsramme: Month 3 through Month 12 (during community-based wearable data collection).
|
Measure Description: The percentage of participants flagged as high-risk for hypertension by the Huawei wearable platform within the total recruited screening cohort. Unit of Measure: Percentage of total participants |
Month 3 through Month 12 (during community-based wearable data collection).
|
|
Association Between Wearable Digital Biomarkers and ABPM-Confirmed Hypertension Risk
Tidsramme: Month 17 through Month 20 (during data cleaning and analytical modelling).
|
Measure Description: Adjusted Odds Ratios derived from logistic regression models assessing the relationship between wearable physiological parameters (heart rate, heart rate variability, sleep duration/quality, physical activity, and PPG blood pressure estimates) and ABPM-confirmed hypertension status. Unit of Measure: Adjusted Odds Ratio (OR) with 95% Confidence Intervals |
Month 17 through Month 20 (during data cleaning and analytical modelling).
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Samarbejdspartnere
Samarbejdspartnere
Efterforskere
Efterforskere
- Ledende efterforsker: Yook Chin Chia, Sunway University
Publikationer og nyttige links
Generelle publikationer
- Islam SMS, Chow CK, Daryabeygikhotbehsara R, Subedi N, Rawstorn J, Tegegne T, Karmakar C, Siddiqui MU, Lambert G, Maddison R. Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis. Eur Heart J Digit Health. 2022 May 2;3(2):323-337. doi: 10.1093/ehjdh/ztac021. eCollection 2022 Jun.
- McEvoy JW, McCarthy CP, Bruno RM, Brouwers S, Canavan MD, Ceconi C, Christodorescu RM, Daskalopoulou SS, Ferro CJ, Gerdts E, Hanssen H, Harris J, Lauder L, McManus RJ, Molloy GJ, Rahimi K, Regitz-Zagrosek V, Rossi GP, Sandset EC, Scheenaerts B, Staessen JA, Uchmanowicz I, Volterrani M, Touyz RM; ESC Scientific Document Group. 2024 ESC Guidelines for the management of elevated blood pressure and hypertension. Eur Heart J. 2024 Oct 7;45(38):3912-4018. doi: 10.1093/eurheartj/ehae178. No abstract available.
- Wang Y, Zhou SS, Liu YQ, Li DD, Hu SY, Wang X, Yi L, Yu YN, Chen YD. Accessibility and usage patterns of wearable devices among Chinese adults: the Huawei Blood Pressure Health Study. Eur Heart J Digit Health. 2025 Aug 5;6(6):1264-1272. doi: 10.1093/ehjdh/ztaf088. eCollection 2025 Nov.
- Stergiou GS, Menti A, Mariglis D, Kollias A. The quest for accurate wearable blood pressure monitors. Hypertens Res. 2026 Mar;49(3):1025-1029. doi: 10.1038/s41440-025-02410-w. Epub 2025 Nov 5.
- Odeh VA, Chen Y, Wang W, Ding X. Recent Advances in the Wearable Devices for Monitoring and Management of Heart Failure. Rev Cardiovasc Med. 2024 Oct 28;25(10):386. doi: 10.31083/j.rcm2510386. eCollection 2024 Oct.
- Chia J, Bhatia KS, Mihailidou AS, Kanagaratnam LB. The Role of Ambulatory Blood Pressure Monitoring in Current Clinical Practice. Heart Lung Circ. 2022 Oct;31(10):1333-1340. doi: 10.1016/j.hlc.2022.06.670. Epub 2022 Aug 4.
Datoer for undersøgelser
Studer store datoer
Studiestart (Anslået)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- Huawei-SU-HTN-01
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
IPD-delingstidsramme
IPD-delingsadgangskriterier
IPD-deling Understøttende informationstype
- STUDY_PROTOCOL
- SAP
- ICF
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .