Single-Arm Trial of Carotid Stenting for Carotid Stenosis (Timing Trial)

12. november 2026 opdateret af: Suzhou Zenith Vascular SciTech Limited

A Prospective, Multicenter, Single-arm, Target Value Clinical Trial to Evaluate the Efficacy and Safety of the Carotid Artery Stent System in the Treatment of Carotid Artery Stenosis

This is a prospective, multicenter, single-group, target value clinical trial planning to enroll 208 eligible subjects. Participants will be treated with the investigational carotid artery stent system and followed up at discharge, 30 days, 6 months, and 12 months postoperatively to evaluate the safety and efficacy of the device for endovascular treatment of carotid artery stenosis.

Studieoversigt

Status

Ikke rekrutterer endnu

Betingelser

Intervention / Behandling

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

208

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Studiesteder

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

General Inclusion Criteria (all must be satisfied):

  1. Age ≥18 years, either sex.
  2. Preoperative carotid duplex ultrasound (DUS) confirms stenosis of the common carotid artery (CCA), internal carotid artery (ICA), or carotid bifurcation, and the subject is deemed suitable for endovascular intervention.
  3. Intraoperative digital subtraction angiography (DSA) confirms symptomatic carotid artery stenosis ≥50% or asymptomatic carotid artery stenosis ≥80% (measured by NASCET criteria). Symptomatic is defined as a non-disabling ischemic stroke or transient ischemic attack (TIA), including cerebral hemisphere events or amaurosis fugax, occurring within 6 months prior to the procedure.
  4. Reference vessel diameter at the target lesion ranges from 3.5 mm to 9.5 mm.
  5. Voluntarily participates in this trial and signs the informed consent form.

CEA High-Risk Inclusion Criteria (at least one criterion must be met):

Clinical High-Risk Factors:

  1. Age >80 years.
  2. Low cardiac output [left ventricular ejection fraction (LVEF) <30%].
  3. Untreated or poorly controlled arrhythmia (recurrent despite standard medical therapy or other treatment).
  4. Cardiac insufficiency (New York Heart Association Class III-IV).
  5. Recent myocardial infarction (occurring between 72 hours and 30 days prior to the procedure).
  6. Unstable angina (Canadian Cardiovascular Society Class 3-4).
  7. Severe chronic obstructive pulmonary disease (COPD), defined as forced expiratory volume in 1 second (FEV1) <50% of predicted value.

Anatomic High-Risk Factors:

  1. Restenosis after prior carotid endarterectomy (CEA).
  2. Contralateral carotid artery occlusion.
  3. Tandem carotid artery lesions.
  4. Carotid artery dissection.
  5. Pseudoaneurysm.

Exclusion Criteria:

  1. Target lesion caused by carotid arteritis.
  2. Target lesion located at the ostium of the common carotid artery.
  3. Severe, long-segment calcification or severe tortuosity at the target lesion preventing adequate stent delivery.
  4. Target lesion is a complete occlusion.
  5. Presence of large acute or subacute thrombus, or arteriovenous malformation adjacent to the target lesion.
  6. Requirement for concurrent stenting or stenting in other territories (intracranial or extracranial) within 30 days after the procedure.
  7. Intracranial hemorrhage within 3 months prior to the procedure.
  8. Large-scale ischemic stroke within 30 days prior to the procedure.
  9. Known intracranial aneurysm that cannot be treated in advance.
  10. Known coagulation disorder (activated partial thromboplastin time [APTT] >3 times the upper limit of normal) or abnormal bleeding diathesis.
  11. Known contraindication to heparin or antiplatelet agents.
  12. Known allergy to device components, contrast agent, or related materials.
  13. Severe hepatic or renal insufficiency (alanine aminotransferase [ALT] or aspartate aminotransferase [AST] >5 times the upper limit of normal; serum creatinine >3 times the upper limit of normal).
  14. Uncontrolled severe hypertension (persistent systolic blood pressure ≥180 mmHg or diastolic blood pressure ≥110 mmHg).
  15. Preoperative bradycardia (heart rate <40 beats per minute).
  16. Preoperative modified Rankin Scale (mRS) score ≥3.
  17. Malignant tumor with extensive metastasis.
  18. Currently participating in another drug or device clinical trial.
  19. Pregnant or lactating women, or women planning pregnancy within 1 year.
  20. Any other condition that, in the investigator's judgment, makes the subject unsuitable for participation in this trial.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Carotid Artery Stent System

All participants will undergo carotid artery stenting (CAS).

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Incidence of In-Stent Restenosis (ISR)
Tidsramme: through study completion, an average of 1 year

Restenosis is defined as ≥50% diameter stenosis occurring within the stent or within 5 mm of the proximal or distal stent edge of the target carotid artery, as assessed by carotid duplex ultrasound (DUS).

through study completion, an average of 1 year
Incidence of Major Adverse Events (MAE)
Tidsramme: through study completion, an average of 1 year

Major adverse events (MAE) are defined as the composite incidence of: (1) death, stroke (ischemic or hemorrhagic), or myocardial infarction (MI) occurring within 30 days after the procedure; and (2) death or ipsilateral ischemic stroke of the target vessel occurring from 31 to 365 days after the procedure.

through study completion, an average of 1 year

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Device Success Rate
Tidsramme: Intraoperative

Defined as the percentage of enrolled subjects in whom device success is achieved. Device success is defined as successful implantation (including delivery, deployment, and expansion) of the stent covering the target lesion, with successful retrieval of the delivery system.

Intraoperative
Procedural Success Rate
Tidsramme: Perioperative

Defined as the percentage of enrolled subjects in whom procedural success is achieved. Procedural success is defined as successful implantation of the stent, with post-procedure angiography demonstrating ≤30% residual stenosis at the target lesion, and freedom from major adverse events (MAE; defined as all-cause death, stroke, or myocardial infarction) prior to hospital discharge.

Perioperative
Incidence of In-Stent Restenosis (ISR)
Tidsramme: 6 months

Defined as the percentage of enrolled subjects who develop ISR at 6 months post-procedure. ISR is defined as restenosis within the stent or within 5 mm proximal or distal to the stent edge of the target carotid artery, as assessed by carotid duplex ultrasound (DUS), with DUS criteria indicating ≥50% diameter stenosis.

6 months
Incidence of Target Lesion Revascularization (TLR)
Tidsramme: 30 days,6 months,12 months

The percentage of enrolled subjects who undergo TLR within 30 days, at 6 months, and at 12 months post-procedure. TLR is defined as any repeat revascularization (including any surgical or percutaneous intervention) of the target lesion after the initial index procedure.

30 days,6 months,12 months
Incidence of Ipsilateral Ischemic Stroke
Tidsramme: 6 months,12 months

Defined as the percentage of enrolled subjects who experience an ipsilateral ischemic stroke at 6 months and 12 months post-procedure. Ipsilateral ischemic stroke is defined as an ischemic stroke occurring in the cerebral hemisphere supplied by the target vessel (the carotid artery treated during the index procedure).

6 months,12 months
Incidence of Adverse Events (AEs) and Serious Adverse Events (SAEs)
Tidsramme: through study completion, an average of 1 year
through study completion, an average of 1 year
Incidence of Device Deficiencies
Tidsramme: through study completion, an average of 1 year
through study completion, an average of 1 year

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Samarbejdspartnere

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. december 2026

Primær færdiggørelse (Anslået)

1. december 2028

Studieafslutning (Anslået)

1. december 2028

Datoer for studieregistrering

Først indsendt

5. november 2026

Først indsendt, der opfyldte QC-kriterier

12. november 2026

Først opslået (Faktiske)

13. november 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

13. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

12. november 2026

Sidst verificeret

1. november 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • ZTYL202401

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .