Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Protective Effect of Biodegradable Collagen Implant (Ologen) in Scleral Thinning After Strabismus Surgery

24. januar 2017 opdateret af: Yonsei University
This study is to investigate protective effect of biodegradable collagen implant in scleral showing after lateral rectus recession in patients with exotropia.

Studieoversigt

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

20

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Seoul, Korea, Republikken, 03722
        • Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

10 år til 70 år (Barn, Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  1. Patients with intermittent exotropia or constant exotropia
  2. Alternate prism cover test showed 20 prism diopters or more than 20 prism diopters exotropia
  3. Subjects who want to do strabismus surgery

Exclusion Criteria:

  1. Subject who had previous strabismus surgery or other ocular surgery history
  2. Thyroid eye disease or other connective tissue disease
  3. Significant bleeding or scleral perforation during operation
  4. Subjects who need to do medial rectus resection, not lateral rectus recession
  5. Subjects who had a plan to do other intra or extraocular surgery within 3 months

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Støttende pleje
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Biodegradable collagen implant
Both eyes are needed to correct strabismus. One eye is randomly selected for the placement of biodegradable collagen implant.
Exotropia was treated with bilateral lateral rectus recession procedure. Lateral rectus recession was done. After lateral rectus recession, no degradable collagen implant was placed in the area, where lateral rectus was original inserted. One eye was randomly selected for the comparison.
Aktiv komparator: Without biodegradable collagen implant
Strabismus surgery is done without placing of biodegradable collagen implant in the other eye.
Exotropia was treated with bilateral lateral rectus recession procedure. Lateral rectus recession was done in the other eye without placing biodegradable collagen implantation.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Scleral thinning assessed with slit photography
Tidsramme: Postoperative 3 months
Scleral thinning at the area, where lateral rectus was originally inserted, was assessed with slit photography. Scleral thinning score was calculated from the Lab color model.
Postoperative 3 months

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Ocular discharge assessed by questionnaire
Tidsramme: Postoperative 1 week
Ocular discharge will be assessed by questionnaire.
Postoperative 1 week
Tearing assessed by questionnaire
Tidsramme: Postoperative 1 week
Tearing will be assessed by questionnaire.
Postoperative 1 week
Foreign body sensation assessed by questionnaire
Tidsramme: Postoperative 1 week
Foreign body sensation will be assessed by questionnaire.
Postoperative 1 week
Collagen implant protrusion assessed by questionnaire
Tidsramme: Postoperative 1 week
Collagen implant protrusion will be assessed by questionnaire.
Postoperative 1 week

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

30. september 2015

Primær færdiggørelse (Faktiske)

10. september 2016

Studieafslutning (Faktiske)

10. september 2016

Datoer for studieregistrering

Først indsendt

22. februar 2016

Først indsendt, der opfyldte QC-kriterier

29. februar 2016

Først opslået (Skøn)

4. marts 2016

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

25. januar 2017

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

24. januar 2017

Sidst verificeret

1. januar 2017

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

IPD-planbeskrivelse

no plan to share individual participant data

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Exotropia or Intermittent Exotropia

Kliniske forsøg med lateral rectus recession with biodegradable collagen implant

Abonner