E-Five Registry: A World-Wide Registry With The Endeavor Zotarolimus Eluting Coronary Stent (eFive)
E-Five Registry: To Evaluate the 'Real World' Clinical Performance of the Medtronic Endeavor ABT-578 Eluting Coronary Stent System; A Prospective, Multicenter Registry
The safety and efficacy of the Endeavor(TM) ABT-578 Eluting Coronary Stent System has been assessed in a series of studies. The stent is coated with a proprietary drug compound that is designed to reduce restenosis.
This prospective multi-center study has been initiated:
- To document the acute and mid-term safety and overall clinical performance of the stent system in a "real world" patient population requiring stent implantation.
- To assess the event rate in patient subgroups with specific clinical indications and/or vessel or lesion characteristics.
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Patient is >18 years of age (or minimum age as required by local regulation)
- The patient has consented to participate by signing the "Patient Informed Consent Form" and/or has authorized the collection and release of his medical information by signing the "Patient Data Release Consent Form".
- The patient is suitable for implantation of one or more Endeavor(TM) ABT-578 Eluting Coronary Stent System in one or more native artery target lesions.
- Lesion length and vessel diameter of the target lesion(s) are according to the "Indications for Use" as mentioned in the "Instructions for Use" that comes with every Endeavor(TM) ABT-578 Eluting Coronary Stent System.
- The patient is willing and able to cooperate with registry procedures and required follow up visits.
Exclusion Criteria:
- Women with known pregnancy or who are lactating.
- Patients with hypersensitivity or allergies to aspirin, heparin, clopidogrel, ticlopidine, drugs such as ABT-578, rapamycin, tacrolimus, sirolimus or similar drugs, or any other analogue or derivative, cobalt, chromium, nickel, molybdenum or contrast media.
- Patients in whom anti-platelet and/pr anticoagulation therapy is contraindicated.
- Patients who are judged to have a lesion that prevents complete inflation of an angioplasty balloon.
- Current medical condition with a life expectancy of less than 12 months.
- The subject is participating in another device or drug study. Subject must have completed the follow-up phase of any previous study at least 30 days prior to enrollment in this trial. The subject may only be enrolled in this E-five registry once.
- Patients with medical conditions that preclude the follow-up as defined in the protocol or that otherwise limits participation in this registry.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
MACE (Major Adverse Cardiac Events)
Zeitfenster: 12 Months
|
MACE is defined as death, myocardial infarction (Q-wave and non-Q wave), emergent cardiac bypass surgery, or target lesion revascularization (repeat PTCA (Percutaneous Transluminal Coronary Angioplasty) or CABG (Coronary Artery Bypass Graft surgery))
|
12 Months
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Ermittler
Ermittler
- Hauptermittler: Ian T Meredith, MD, Monash Medical Centre, Melbourne, Australia
- Hauptermittler: Chaim Lotan, MD, Hadassah University Hospital, Jerusalem, Israel
- Hauptermittler: Martin T Rothman, MD, London Chest Hospital, London, United Kingdom
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Remak E, Manson S, Hutton J, Brasseur P, Olivier E, Gershlick A. Cost-effectiveness of the Endeavor stent in de novo native coronary artery lesions updated with contemporary data. EuroIntervention. 2010 Feb;5(7):826-32. doi: 10.4244/eijv5i7a138.
- Fajadet J, Wijns W, Laarman GJ, Kuck KH, Ormiston J, Munzel T, Popma JJ, Fitzgerald PJ, Bonan R, Kuntz RE; ENDEAVOR II Investigators. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation. 2006 Aug 22;114(8):798-806. doi: 10.1161/CIRCULATIONAHA.105.591206. Epub 2006 Aug 14.
- Jain AK, Meredith IT, Lotan C, Rothman MT, Pateraki S; E-Five Investigators. Real-world safety and efficacy of the endeavor zotarolimus-eluting stent: early data from the E-Five Registry. Am J Cardiol. 2007 Oct 22;100(8B):77M-83M. doi: 10.1016/j.amjcard.2007.08.026.
- Lotan C, Meredith IT, Mauri L, Liu M, Rothman MT; E-Five Investigators. Safety and effectiveness of the Endeavor zotarolimus-eluting stent in real-world clinical practice: 12-month data from the E-Five registry. JACC Cardiovasc Interv. 2009 Dec;2(12):1227-35. doi: 10.1016/j.jcin.2009.10.001. Erratum In: JACC Cardiovasc Interv. 2010 Feb;3(2):264.
- Jain AK, Lotan C, Meredith IT, Feres F, Zambahari R, Sinha N, Rothman MT; E-Five Registry Investigators. Twelve-month outcomes in patients with diabetes implanted with a zotarolimus-eluting stent: results from the E-Five Registry. Heart. 2010 Jun;96(11):848-53. doi: 10.1136/hrt.2009.184150.
- Meredith I, Rothman M, Erglis A, Parikh K, Lotan C; E-Five Investigators. Extended follow-up safety and effectiveness of the Endeavor zotarolimus-eluting stent in real-world clinical practice: two-year follow-up from the E-Five Registry. Catheter Cardiovasc Interv. 2011 Jun 1;77(7):993-1000. doi: 10.1002/ccd.22803. Epub 2010 Dec 3.
- Lotan C, Meredith IT, Jain A, Feres F, Firszt A, Garcia AF, Rothman MT. Clinical outcomes by geographic region for patients implanted with the zotarolimus-eluting stent. Arq Bras Cardiol. 2011 May;96(5):353-62. doi: 10.1590/s0066-782x2011005000033. Epub 2011 Apr 1. English, Portuguese, Spanish.
- Kandzari DE, Leon MB, Popma JJ, Fitzgerald PJ, O'Shaughnessy C, Ball MW, Turco M, Applegate RJ, Gurbel PA, Midei MG, Badre SS, Mauri L, Thompson KP, LeNarz LA, Kuntz RE; ENDEAVOR III Investigators. Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial. J Am Coll Cardiol. 2006 Dec 19;48(12):2440-7. doi: 10.1016/j.jacc.2006.08.035. Epub 2006 Nov 28.
Nützliche Links
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- Protocol Final version1.1
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .