E-Five Registry: A World-Wide Registry With The Endeavor Zotarolimus Eluting Coronary Stent (eFive)
E-Five Registry: To Evaluate the 'Real World' Clinical Performance of the Medtronic Endeavor ABT-578 Eluting Coronary Stent System; A Prospective, Multicenter Registry
The safety and efficacy of the Endeavor(TM) ABT-578 Eluting Coronary Stent System has been assessed in a series of studies. The stent is coated with a proprietary drug compound that is designed to reduce restenosis.
This prospective multi-center study has been initiated:
- To document the acute and mid-term safety and overall clinical performance of the stent system in a "real world" patient population requiring stent implantation.
- To assess the event rate in patient subgroups with specific clinical indications and/or vessel or lesion characteristics.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Patient is >18 years of age (or minimum age as required by local regulation)
- The patient has consented to participate by signing the "Patient Informed Consent Form" and/or has authorized the collection and release of his medical information by signing the "Patient Data Release Consent Form".
- The patient is suitable for implantation of one or more Endeavor(TM) ABT-578 Eluting Coronary Stent System in one or more native artery target lesions.
- Lesion length and vessel diameter of the target lesion(s) are according to the "Indications for Use" as mentioned in the "Instructions for Use" that comes with every Endeavor(TM) ABT-578 Eluting Coronary Stent System.
- The patient is willing and able to cooperate with registry procedures and required follow up visits.
Exclusion Criteria:
- Women with known pregnancy or who are lactating.
- Patients with hypersensitivity or allergies to aspirin, heparin, clopidogrel, ticlopidine, drugs such as ABT-578, rapamycin, tacrolimus, sirolimus or similar drugs, or any other analogue or derivative, cobalt, chromium, nickel, molybdenum or contrast media.
- Patients in whom anti-platelet and/pr anticoagulation therapy is contraindicated.
- Patients who are judged to have a lesion that prevents complete inflation of an angioplasty balloon.
- Current medical condition with a life expectancy of less than 12 months.
- The subject is participating in another device or drug study. Subject must have completed the follow-up phase of any previous study at least 30 days prior to enrollment in this trial. The subject may only be enrolled in this E-five registry once.
- Patients with medical conditions that preclude the follow-up as defined in the protocol or that otherwise limits participation in this registry.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
MACE (Major Adverse Cardiac Events)
Ramy czasowe: 12 Months
|
MACE is defined as death, myocardial infarction (Q-wave and non-Q wave), emergent cardiac bypass surgery, or target lesion revascularization (repeat PTCA (Percutaneous Transluminal Coronary Angioplasty) or CABG (Coronary Artery Bypass Graft surgery))
|
12 Months
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Ian T Meredith, MD, Monash Medical Centre, Melbourne, Australia
- Główny śledczy: Chaim Lotan, MD, Hadassah University Hospital, Jerusalem, Israel
- Główny śledczy: Martin T Rothman, MD, London Chest Hospital, London, United Kingdom
Publikacje i pomocne linki
Publikacje ogólne
- Remak E, Manson S, Hutton J, Brasseur P, Olivier E, Gershlick A. Cost-effectiveness of the Endeavor stent in de novo native coronary artery lesions updated with contemporary data. EuroIntervention. 2010 Feb;5(7):826-32. doi: 10.4244/eijv5i7a138.
- Fajadet J, Wijns W, Laarman GJ, Kuck KH, Ormiston J, Munzel T, Popma JJ, Fitzgerald PJ, Bonan R, Kuntz RE; ENDEAVOR II Investigators. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation. 2006 Aug 22;114(8):798-806. doi: 10.1161/CIRCULATIONAHA.105.591206. Epub 2006 Aug 14.
- Jain AK, Meredith IT, Lotan C, Rothman MT, Pateraki S; E-Five Investigators. Real-world safety and efficacy of the endeavor zotarolimus-eluting stent: early data from the E-Five Registry. Am J Cardiol. 2007 Oct 22;100(8B):77M-83M. doi: 10.1016/j.amjcard.2007.08.026.
- Lotan C, Meredith IT, Mauri L, Liu M, Rothman MT; E-Five Investigators. Safety and effectiveness of the Endeavor zotarolimus-eluting stent in real-world clinical practice: 12-month data from the E-Five registry. JACC Cardiovasc Interv. 2009 Dec;2(12):1227-35. doi: 10.1016/j.jcin.2009.10.001. Erratum In: JACC Cardiovasc Interv. 2010 Feb;3(2):264.
- Jain AK, Lotan C, Meredith IT, Feres F, Zambahari R, Sinha N, Rothman MT; E-Five Registry Investigators. Twelve-month outcomes in patients with diabetes implanted with a zotarolimus-eluting stent: results from the E-Five Registry. Heart. 2010 Jun;96(11):848-53. doi: 10.1136/hrt.2009.184150.
- Meredith I, Rothman M, Erglis A, Parikh K, Lotan C; E-Five Investigators. Extended follow-up safety and effectiveness of the Endeavor zotarolimus-eluting stent in real-world clinical practice: two-year follow-up from the E-Five Registry. Catheter Cardiovasc Interv. 2011 Jun 1;77(7):993-1000. doi: 10.1002/ccd.22803. Epub 2010 Dec 3.
- Lotan C, Meredith IT, Jain A, Feres F, Firszt A, Garcia AF, Rothman MT. Clinical outcomes by geographic region for patients implanted with the zotarolimus-eluting stent. Arq Bras Cardiol. 2011 May;96(5):353-62. doi: 10.1590/s0066-782x2011005000033. Epub 2011 Apr 1. English, Portuguese, Spanish.
- Kandzari DE, Leon MB, Popma JJ, Fitzgerald PJ, O'Shaughnessy C, Ball MW, Turco M, Applegate RJ, Gurbel PA, Midei MG, Badre SS, Mauri L, Thompson KP, LeNarz LA, Kuntz RE; ENDEAVOR III Investigators. Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial. J Am Coll Cardiol. 2006 Dec 19;48(12):2440-7. doi: 10.1016/j.jacc.2006.08.035. Epub 2006 Nov 28.
Przydatne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- Protocol Final version1.1
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .