To Evaluate the Visual Performance After Bilateral Implantation of Multifocal Intraocular Lenses
Visual Performance of Multifocal Intraocular Lenses Following Removal of the Crystalline Lens
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
This study evaluates the visual performance after bilateral implantation of multifocal intraocular lenses (IOL). This prospective study is performed at the department of Ophthalmology, Goethe University, Frankfurt, Germany.
Patients who received bilateral implantation of a multifocal intraocular lens pre-enrollment were included consecutively. Exclusion criteria were previous ocular surgeries excluding cataract surgery and refractive lens exchange, regular corneal astigmatism of >1.5 diopter, and ocular pathologies or corneal abnormalities. At 3 months postoperative examination included manifest refraction; monocular and binocular uncorrected (UCVA) and distance-corrected (DCVA) visual acuity in at far, intermediate at near distance (logMAR); slit-lamp examination. 3 months postoperatively defocus testing, binocular contrast sensitivity (CS) under photopic and mesopic conditions, and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence were performed.
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Kontakte und Standorte
Studienorte
-
-
Hessen
-
Frankfurt am Main, Hessen, Deutschland, 60590
- Department of ophthalmology University clinic Frankfurt
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
- Kind
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- bilateral cataract surgery or refractive lens exchange with the implantation a multifocal intraocular lens
- a regular corneal astigmatism < 1.5 D measured with Pentacam (Oculus, Wetzlar, Germany)
Exclusion Criteria:
- other previous ocular surgeries
- ocular pathologies
- corneal abnormalities
- endothelial cell count below 2000/mm²
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Bestkorrigierte Sehschärfe auf mittlere Distanz
Zeitfenster: Gemessen 3 Monate nach der Linsenoperation
|
Monokulare und binokulare korrigierte Sehschärfe auf mittlere Distanz gemessen in logMAR 3 Monate nach Linsenoperation
|
Gemessen 3 Monate nach der Linsenoperation
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Beste korrigierte Sehschärfe im Nahbereich
Zeitfenster: Gemessen 3 Monate nach der Linsenoperation
|
Monokulare und binokulare bestkorrigierte Sehschärfe im Nahbereich gemessen in logMAR 3 Monate nach Linsenoperation
|
Gemessen 3 Monate nach der Linsenoperation
|
|
Unkorrigierte Sehschärfe in der Ferne
Zeitfenster: Gemessen 3 Monate nach der Linsenoperation
|
Monokulare und binokulare unkorrigierte Sehschärfe in der Ferne gemessen in logMAR 3 Monate nach Linsenoperation
|
Gemessen 3 Monate nach der Linsenoperation
|
|
Unkorrigierte Sehschärfe auf mittlere Distanz
Zeitfenster: Gemessen 3 Monate nach der Linsenoperation
|
Monokulare und binokulare unkorrigierte Sehschärfe auf Zwischendistanz gemessen in logMAR 3 Monate nach Linsenoperation
|
Gemessen 3 Monate nach der Linsenoperation
|
|
Unkorrigierte Sehschärfe in der Nähe
Zeitfenster: Gemessen 3 Monate nach der Linsenoperation
|
Monokulare und binokulare unkorrigierte Sehschärfe im Nahbereich gemessen in logMAR 3 Monate nach Linsenoperation
|
Gemessen 3 Monate nach der Linsenoperation
|
|
Test der Defokussierungskurve
Zeitfenster: Gemessen 3 Monate nach der Linsenoperation
|
Die Defokuskurve (monokular und binokular) wurde von -5,0 dpt bis +2,0 dpt in 0,5-dpt-Schritten unter photopischen Beleuchtungsbedingungen (ETDRS) getestet.
|
Gemessen 3 Monate nach der Linsenoperation
|
|
Best corrected visual acuity at far distance
Zeitfenster: Measured 3 month after lens surgery
|
Monocular and binocular best corrected visual acuity at far distance measured in logMAR 3 month after lens surgery
|
Measured 3 month after lens surgery
|
|
Binocular contrast sensitivity (CS) under photopic, mesopic, and mesopic with glare lighting conditions
Zeitfenster: Measured 3 month after lens surgery
|
Binocular contrast sensitivity (CS) was measured under photopic, mesopic (0.167 cd/m²), and mesopic with glare lighting conditions by means of the "Frankfurt-Freiburg Contrast and Acuity Test System" (FF-CATS)
|
Measured 3 month after lens surgery
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Ermittler
Ermittler
- Studienstuhl: Thomas Kohnen, Professor, Goethe University Clinic Frankfurt
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 102/13
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Sehschärfe
-
NCT05026658Abgeschlossen
-
NCT04902365Aktiv, nicht rekrutierendVisual Snow-Syndrom | Neuro-Ophthalmologie
-
NCT04925232AbgeschlossenVisual Snow-Syndrom
-
NCT05569733Abgeschlossen
-
NCT05229731Zurückgezogen
-
NCT04184726AbgeschlossenVisual Snow-Syndrom | Photophobie | Schleppphänomen | Visuelle Aura
-
NCT05524493RekrutierungEpilepsie | Migräne | Visual Snow-Syndrom
-
NCT07110493RekrutierungGesunder Freiwilliger | Visual Snow-Syndrom | Farbenblindheit
-
NCT06961864RekrutierungGesund | Migräne | Visual Snow-Syndrom