Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Förderung und Kartierung nicht-invasiver Hirnstimulationstechniken (BoMAP NIBS)

17. September 2026 aktualisiert von: Friedhelm Hummel, Ecole Polytechnique Fédérale de Lausanne

Steigerung und Kartierung von durch nicht-invasive Hirnstimulation induzierter Plastizität beim Menschen

In this study we applied TMS to the hand area of M1 whilst acquiring fMRI of the brain. This study tested whether a higher-frequency form of brain stimulation, called high-gamma (100Hz) intermittent theta burst stimulation (iTBS), more effectively increases brain excitability than the standard 50Hz iTBS. In a double-blind, randomized study with 22 healthy participants, brain activity and motor responses were measured using TMS-fMRI. The 100Hz iTBS condition produced stronger and more consistent increases in motor excitability and greater activation of sensorimotor brain regions compared to 50Hz and sham stimulation, suggesting it may be a more effective approach for non-invasive neuromodulation.

Studienübersicht

Status

Abgeschlossen

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

This study investigates whether a modified form of brain stimulation called high-gamma intermittent theta burst stimulation (iTBS) can more effectively and consistently increase brain excitability compared to the standard iTBS protocol. iTBS is a non-invasive method that uses magnetic pulses to influence brain activity, but responses vary widely between people.

In this double-blind, randomized, within-subject study, 22 healthy adults completed three sessions of brain stimulation combined with functional MRI (TMS-fMRI). Each participant received conventional 50Hz iTBS, high-gamma 100Hz iTBS, and a sham (placebo) condition on separate visits. Changes in motor cortex excitability were measured using motor-evoked potentials (MEPs), and brain activity and connectivity were assessed using fMRI.

The results showed that 100Hz iTBS produced stronger and more reliable increases in cortical excitability compared to both the 50Hz and sham conditions. High-gamma iTBS also activated broader areas of the sensorimotor network and showed stronger links between stimulation strength and neural response. These findings suggest that high-gamma iTBS may be a more effective and physiologically relevant approach for non-invasive brain stimulation in humans.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

22

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Canton of Geneva
      • Geneva, Canton of Geneva, Schweiz, 1202
        • Campus Biotech

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 35 Jahre (Erwachsene)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Right handed

Exclusion Criteria:

  • Contraindications to either TMS or MRI:

Pregnant Metal implants Use of recreational drugs Neurological conditions History of seizures or epilepsy

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Grundlegende Wissenschaft
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: 100Hz iTBS (intermittent theta burst protocol of rTMS)

The high-frequency of the stimulation is what distinguishes it from the other stimulation types and it is the goal of the study to see if this stimulation protocol is more effective than the classical protocol

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Andere Namen:
  • rTMS
  • iTBS
Aktiver Komparator: 50Hz iTBS (intermittent theta burst protocol of rTMS)

The classical low-frequency protocol of stimulation, this one is being used to compare to the novel high-frequency protocol

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Andere Namen:
  • rTMS
  • iTBS
Schein-Komparator: Sham iTBS (intermittent theta burst protocol of rTMS)

The sham stimulation was delivered with a 50Hz iTBS protocol except that the stimulation intensity was halved so as to retain the sensation of stimulation whilst not activating neurons

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Andere Namen:
  • rTMS
  • iTBS

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Functional magnetic resonance imaging (fMRI)
Zeitfenster: Throughout the whole experiment, for a total of 26 minutes

fMRI of the brain and spinal chord were acquired during stimulation with single pulse TMS to elucidate the changes in BOLD activity occurring from the intervention.

Throughout the whole experiment, for a total of 26 minutes
Motor evoked potentials (MEPs)
Zeitfenster: MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.

When single pulses of TMS are applied to M1 hand region, MEPs are evoked in the corresponding hand muscle which can be measured with electromyography (EMG). The amplitude of the MEPs before and after the iTBS interventions are then measured and compared to determine the response to the iTBS, whether this is facilitation, suppression, or no change.

MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

2. Februar 2023

Primärer Abschluss (Tatsächlich)

12. April 2024

Studienabschluss (Tatsächlich)

12. April 2024

Studienanmeldedaten

Zuerst eingereicht

19. Februar 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

19. Februar 2026

Zuerst gepostet (Tatsächlich)

24. Februar 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

22. September 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

17. September 2026

Zuletzt verifiziert

1. September 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Schlüsselwörter

Andere Studien-ID-Nummern

  • 2021-01887

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .