Potenciación y Cartografía de Técnicas de Estimulación Cerebral No Invasivas (BoMAP NIBS)
Potenciación y Cartografía de la Plasticidad Inducida por Estimulación Cerebral No Invasiva en Humanos
In this study we applied TMS to the hand area of M1 whilst acquiring fMRI of the brain. This study tested whether a higher-frequency form of brain stimulation, called high-gamma (100Hz) intermittent theta burst stimulation (iTBS), more effectively increases brain excitability than the standard 50Hz iTBS. In a double-blind, randomized study with 22 healthy participants, brain activity and motor responses were measured using TMS-fMRI. The 100Hz iTBS condition produced stronger and more consistent increases in motor excitability and greater activation of sensorimotor brain regions compared to 50Hz and sham stimulation, suggesting it may be a more effective approach for non-invasive neuromodulation.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
This study investigates whether a modified form of brain stimulation called high-gamma intermittent theta burst stimulation (iTBS) can more effectively and consistently increase brain excitability compared to the standard iTBS protocol. iTBS is a non-invasive method that uses magnetic pulses to influence brain activity, but responses vary widely between people.
In this double-blind, randomized, within-subject study, 22 healthy adults completed three sessions of brain stimulation combined with functional MRI (TMS-fMRI). Each participant received conventional 50Hz iTBS, high-gamma 100Hz iTBS, and a sham (placebo) condition on separate visits. Changes in motor cortex excitability were measured using motor-evoked potentials (MEPs), and brain activity and connectivity were assessed using fMRI.
The results showed that 100Hz iTBS produced stronger and more reliable increases in cortical excitability compared to both the 50Hz and sham conditions. High-gamma iTBS also activated broader areas of the sensorimotor network and showed stronger links between stimulation strength and neural response. These findings suggest that high-gamma iTBS may be a more effective and physiologically relevant approach for non-invasive brain stimulation in humans.
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Canton of Geneva
-
Geneva, Canton of Geneva, Suiza, 1202
- Campus Biotech
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Right handed
Exclusion Criteria:
- Contraindications to either TMS or MRI:
Pregnant Metal implants Use of recreational drugs Neurological conditions History of seizures or epilepsy
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Doble
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: 100Hz iTBS (intermittent theta burst protocol of rTMS)
The high-frequency of the stimulation is what distinguishes it from the other stimulation types and it is the goal of the study to see if this stimulation protocol is more effective than the classical protocol |
iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.
Otros nombres:
|
|
Comparador activo: 50Hz iTBS (intermittent theta burst protocol of rTMS)
The classical low-frequency protocol of stimulation, this one is being used to compare to the novel high-frequency protocol |
iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.
Otros nombres:
|
|
Comparador falso: Sham iTBS (intermittent theta burst protocol of rTMS)
The sham stimulation was delivered with a 50Hz iTBS protocol except that the stimulation intensity was halved so as to retain the sensation of stimulation whilst not activating neurons |
iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Functional magnetic resonance imaging (fMRI)
Periodo de tiempo: Throughout the whole experiment, for a total of 26 minutes
|
fMRI of the brain and spinal chord were acquired during stimulation with single pulse TMS to elucidate the changes in BOLD activity occurring from the intervention. |
Throughout the whole experiment, for a total of 26 minutes
|
|
Motor evoked potentials (MEPs)
Periodo de tiempo: MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.
|
When single pulses of TMS are applied to M1 hand region, MEPs are evoked in the corresponding hand muscle which can be measured with electromyography (EMG). The amplitude of the MEPs before and after the iTBS interventions are then measured and compared to determine the response to the iTBS, whether this is facilitation, suppression, or no change. |
MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
Otros números de identificación del estudio
- 2021-01887
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .