- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT05161520
Einfluss der Kapselspannring-Implantation auf die Position der Intraokularlinse
Einfluss der Implantation eines Kapselspannrings auf die Neigung und Dezentrierung der Intraokularlinse bei Kataraktpatienten mit hoher Myopie: eine randomisierte kontrollierte Studie
This is a randomized controlled trial to investigate the effect of capsular tension ring (CTR) implantation on intraocular lens (IOL) tilt and decentration in cataract patients with high myopia.
Studienübersicht
Status
Bedingungen
Detaillierte Beschreibung
Exact positioning and alignment of the IOL with the visual axis are the prerequisites of high-quality visual performance after cataract surgery. A certain degree of IOL tilt and decentration occur after uneventful cataract surgery, most of which are clinically tolerant. However, the relatively large capsular bag volume, zonular weakness, and vitreous liquefaction in cataract patients with high myopia may increase the IOL position instability, such as tilt, decentration and even dislocation, leading to the deterioration of visual function. Thus, how to improve the long-term stability of IOL position in high myopic cataract patients is an urgent issue to be addressed.
Previous studies have shown that CTR implantation during cataract surgery can increase the IOL stability in patients with normal axial length; however, its impact on IOL position of cataract patients with high myopia remains unclear.
In this randomized clinical trial, patients who meet the inclusion criteria will be divided into three layers according to the axial length:
(1)26mm≤AL<28mm (2)28mm≤AL<30mm (3)AL≥30mm
We are going to recruit 186 patients in total, with 62 patients in each layer. Patients on each layer will be randomly divided into experimental group (CTR implantation) and control group (only IOL implantation). If both eyes of a patient meet the inclusion criteria, only the first operated eye is included in the statistics analysis.
All included patients will be followed up at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively. Visual acuity, IOL tilt, IOL decentration, posterior capsule attachment with IOL, anterior capsule contraction, posterior capsular opacification, and visual quality will be measured and compared between the experimental group and the control group at different timepoints.
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510060
- Zhongshan Ophthalmic Center, Sun Yat-sen University
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- > 18 years old;
- axis length≥26mm;
- Visually significant cataract;
- The patient is willing and able to complete all necessary follow-ups and examinations.
Exclusion Criteria:
- Intraoperative or postoperative complications: such as intraoperative posterior capsular rupture, zonular dehiscence, secondary glaucoma, endophthalmitis, etc.;
- Other ocular comorbidity: such as keratopathy, glaucoma, uveitis, retinopathy, lens dislocation and ocular trauma, etc.;
- History of intraocular surgery;
- Severe systemic diseases: such as severe hypertension, diabetes, heart disease, Alzheimer's, Parkinson, etc.;
- Any condition that the study physician considers to be an impediment to the clinical trial.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Aktiver Komparator: IOL plus CTR Patienten werden einer Phakoemulsifikation in Kombination mit einer IOL- und CTR-Implantation unterzogen.
|
Device: CTR (276001G; OPHTEC BV, Netherlands) Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, a capsular tension ring is implanted in the capsular bag and then IOL is implanted. |
|
Placebo-Komparator: Einzellinsenpatienten werden einer Phakoemulsifikation in Kombination mit einer IOL-Implantation unterzogen.
|
Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, IOL is implanted in the capsular bag. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
IOL dencentration
Zeitfenster: 3 months after surgery
|
Measured by anterior segment OCT (CASIA2) |
3 months after surgery
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
IOL dencentration
Zeitfenster: Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
|
IOL tilt
Zeitfenster: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Anterior capsule contraction
Zeitfenster: Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Compare the area of anterior capsule opening recorded by slit lamp photograph and analyzed by Image J software. |
Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsule attachment with IOL
Zeitfenster: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) and analyzed by Image J software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsular opacification
Zeitfenster: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Recorded by slit lamp photograph and analyzed by EPCO2000 analysis software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
BCVA
Zeitfenster: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
BCVA is evaluated with ETDRS visual acuity chart. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Optical quality
Zeitfenster: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by OPD-SCAN III. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Visual function
Zeitfenster: 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by visual function assessment questionnaires. |
3 months, 6 months, 1 year, 3 year after surgery
|
|
Incidence of postoperative complications
Zeitfenster: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
IOL dislocation, retinal detachment, etc. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Time to Nd:YAG posterior capsulotomy
Zeitfenster: Up to 3 years
|
Time from cataract surgery to Nd:YAG laser posterior capsulotomy. Participants without capsulotomy will be censored at their last follow-up visit. Cumulative probability of capsulotomy over time will be estimated using Kaplan-Meier survival analysis. |
Up to 3 years
|
Mitarbeiter und Ermittler
Sponsor
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Lin H, Zhang J, Jin A, Zhang Y, Zhang Y, Jin L, Xu Y, Xie X, Qiu X, Dai B, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Power Calculation in Highly Myopic Eyes: Secondary Analysis of a Randomized Clinical Trial. JAMA Ophthalmol. 2025 May 1;143(5):373-381. doi: 10.1001/jamaophthalmol.2025.0110.
- Lin H, Zhang J, Zhang Y, Jin A, Zhang Y, Jin L, Xu Y, Xie X, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Randomized Clinical Trial. JAMA Ophthalmol. 2024 Aug 1;142(8):708-715. doi: 10.1001/jamaophthalmol.2024.2215.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 2021KYPJ128
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .