Indvirkning af kapselspændingsringimplantation på intraokulær linseposition
Indvirkning af kapselspændingsringimplantation på intraokulær linsehældning og decentration hos kataraktpatienter med høj nærsynethed: et randomiseret kontrolleret forsøg
This is a randomized controlled trial to investigate the effect of capsular tension ring (CTR) implantation on intraocular lens (IOL) tilt and decentration in cataract patients with high myopia.
Studieoversigt
Status
Betingelser
Detaljeret beskrivelse
Exact positioning and alignment of the IOL with the visual axis are the prerequisites of high-quality visual performance after cataract surgery. A certain degree of IOL tilt and decentration occur after uneventful cataract surgery, most of which are clinically tolerant. However, the relatively large capsular bag volume, zonular weakness, and vitreous liquefaction in cataract patients with high myopia may increase the IOL position instability, such as tilt, decentration and even dislocation, leading to the deterioration of visual function. Thus, how to improve the long-term stability of IOL position in high myopic cataract patients is an urgent issue to be addressed.
Previous studies have shown that CTR implantation during cataract surgery can increase the IOL stability in patients with normal axial length; however, its impact on IOL position of cataract patients with high myopia remains unclear.
In this randomized clinical trial, patients who meet the inclusion criteria will be divided into three layers according to the axial length:
(1)26mm≤AL<28mm (2)28mm≤AL<30mm (3)AL≥30mm
We are going to recruit 186 patients in total, with 62 patients in each layer. Patients on each layer will be randomly divided into experimental group (CTR implantation) and control group (only IOL implantation). If both eyes of a patient meet the inclusion criteria, only the first operated eye is included in the statistics analysis.
All included patients will be followed up at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively. Visual acuity, IOL tilt, IOL decentration, posterior capsule attachment with IOL, anterior capsule contraction, posterior capsular opacification, and visual quality will be measured and compared between the experimental group and the control group at different timepoints.
Undersøgelsestype
Tilmelding (Anslået)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Guangdong
-
Guangzhou, Guangdong, Kina, 510060
- Zhongshan Ophthalmic Center, Sun Yat-sen University
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- > 18 years old;
- axis length≥26mm;
- Visually significant cataract;
- The patient is willing and able to complete all necessary follow-ups and examinations.
Exclusion Criteria:
- Intraoperative or postoperative complications: such as intraoperative posterior capsular rupture, zonular dehiscence, secondary glaucoma, endophthalmitis, etc.;
- Other ocular comorbidity: such as keratopathy, glaucoma, uveitis, retinopathy, lens dislocation and ocular trauma, etc.;
- History of intraocular surgery;
- Severe systemic diseases: such as severe hypertension, diabetes, heart disease, Alzheimer's, Parkinson, etc.;
- Any condition that the study physician considers to be an impediment to the clinical trial.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: IOL plus CTR Patienter vil gennemgå phacoemulsification kombineret med IOL og CTR implantation.
|
Device: CTR (276001G; OPHTEC BV, Netherlands) Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, a capsular tension ring is implanted in the capsular bag and then IOL is implanted. |
|
Placebo komparator: enkelt IOL-patienter vil gennemgå phacoemulsification kombineret med IOL-implantation.
|
Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, IOL is implanted in the capsular bag. |
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
IOL dencentration
Tidsramme: 3 months after surgery
|
Measured by anterior segment OCT (CASIA2) |
3 months after surgery
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
IOL dencentration
Tidsramme: Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
|
IOL tilt
Tidsramme: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Anterior capsule contraction
Tidsramme: Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Compare the area of anterior capsule opening recorded by slit lamp photograph and analyzed by Image J software. |
Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsule attachment with IOL
Tidsramme: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) and analyzed by Image J software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsular opacification
Tidsramme: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Recorded by slit lamp photograph and analyzed by EPCO2000 analysis software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
BCVA
Tidsramme: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
BCVA is evaluated with ETDRS visual acuity chart. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Optical quality
Tidsramme: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by OPD-SCAN III. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Visual function
Tidsramme: 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by visual function assessment questionnaires. |
3 months, 6 months, 1 year, 3 year after surgery
|
|
Incidence of postoperative complications
Tidsramme: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
IOL dislocation, retinal detachment, etc. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Time to Nd:YAG posterior capsulotomy
Tidsramme: Up to 3 years
|
Time from cataract surgery to Nd:YAG laser posterior capsulotomy. Participants without capsulotomy will be censored at their last follow-up visit. Cumulative probability of capsulotomy over time will be estimated using Kaplan-Meier survival analysis. |
Up to 3 years
|
Samarbejdspartnere og efterforskere
Sponsor
Publikationer og nyttige links
Generelle publikationer
- Lin H, Zhang J, Jin A, Zhang Y, Zhang Y, Jin L, Xu Y, Xie X, Qiu X, Dai B, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Power Calculation in Highly Myopic Eyes: Secondary Analysis of a Randomized Clinical Trial. JAMA Ophthalmol. 2025 May 1;143(5):373-381. doi: 10.1001/jamaophthalmol.2025.0110.
- Lin H, Zhang J, Zhang Y, Jin A, Zhang Y, Jin L, Xu Y, Xie X, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Randomized Clinical Trial. JAMA Ophthalmol. 2024 Aug 1;142(8):708-715. doi: 10.1001/jamaophthalmol.2024.2215.
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Faktiske)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 2021KYPJ128
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .