- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT05161520
Влияние имплантации капсульного натяжного кольца на положение интраокулярной линзы
Влияние имплантации кольца натяжения капсулы на наклон и децентрацию интраокулярной линзы у пациентов с катарактой и близорукостью высокой степени: рандомизированное контролируемое исследование
This is a randomized controlled trial to investigate the effect of capsular tension ring (CTR) implantation on intraocular lens (IOL) tilt and decentration in cataract patients with high myopia.
Обзор исследования
Статус
Условия
Подробное описание
Exact positioning and alignment of the IOL with the visual axis are the prerequisites of high-quality visual performance after cataract surgery. A certain degree of IOL tilt and decentration occur after uneventful cataract surgery, most of which are clinically tolerant. However, the relatively large capsular bag volume, zonular weakness, and vitreous liquefaction in cataract patients with high myopia may increase the IOL position instability, such as tilt, decentration and even dislocation, leading to the deterioration of visual function. Thus, how to improve the long-term stability of IOL position in high myopic cataract patients is an urgent issue to be addressed.
Previous studies have shown that CTR implantation during cataract surgery can increase the IOL stability in patients with normal axial length; however, its impact on IOL position of cataract patients with high myopia remains unclear.
In this randomized clinical trial, patients who meet the inclusion criteria will be divided into three layers according to the axial length:
(1)26mm≤AL<28mm (2)28mm≤AL<30mm (3)AL≥30mm
We are going to recruit 186 patients in total, with 62 patients in each layer. Patients on each layer will be randomly divided into experimental group (CTR implantation) and control group (only IOL implantation). If both eyes of a patient meet the inclusion criteria, only the first operated eye is included in the statistics analysis.
All included patients will be followed up at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively. Visual acuity, IOL tilt, IOL decentration, posterior capsule attachment with IOL, anterior capsule contraction, posterior capsular opacification, and visual quality will be measured and compared between the experimental group and the control group at different timepoints.
Тип исследования
Регистрация (Оцененный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Guangdong
-
Guangzhou, Guangdong, Китай, 510060
- Zhongshan Ophthalmic Center, Sun Yat-sen University
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- > 18 years old;
- axis length≥26mm;
- Visually significant cataract;
- The patient is willing and able to complete all necessary follow-ups and examinations.
Exclusion Criteria:
- Intraoperative or postoperative complications: such as intraoperative posterior capsular rupture, zonular dehiscence, secondary glaucoma, endophthalmitis, etc.;
- Other ocular comorbidity: such as keratopathy, glaucoma, uveitis, retinopathy, lens dislocation and ocular trauma, etc.;
- History of intraocular surgery;
- Severe systemic diseases: such as severe hypertension, diabetes, heart disease, Alzheimer's, Parkinson, etc.;
- Any condition that the study physician considers to be an impediment to the clinical trial.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Одинокий
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: ИОЛ плюс CTR Пациентам будет проведена факоэмульсификация в сочетании с имплантацией ИОЛ и CTR.
|
Device: CTR (276001G; OPHTEC BV, Netherlands) Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, a capsular tension ring is implanted in the capsular bag and then IOL is implanted. |
|
Плацебо Компаратор: пациенты с одиночной ИОЛ будут подвергаться факоэмульсификации в сочетании с имплантацией ИОЛ.
|
Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, IOL is implanted in the capsular bag. |
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
IOL dencentration
Временное ограничение: 3 months after surgery
|
Measured by anterior segment OCT (CASIA2) |
3 months after surgery
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
IOL dencentration
Временное ограничение: Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
|
IOL tilt
Временное ограничение: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Anterior capsule contraction
Временное ограничение: Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Compare the area of anterior capsule opening recorded by slit lamp photograph and analyzed by Image J software. |
Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsule attachment with IOL
Временное ограничение: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) and analyzed by Image J software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsular opacification
Временное ограничение: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Recorded by slit lamp photograph and analyzed by EPCO2000 analysis software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
BCVA
Временное ограничение: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
BCVA is evaluated with ETDRS visual acuity chart. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Optical quality
Временное ограничение: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by OPD-SCAN III. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Visual function
Временное ограничение: 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by visual function assessment questionnaires. |
3 months, 6 months, 1 year, 3 year after surgery
|
|
Incidence of postoperative complications
Временное ограничение: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
IOL dislocation, retinal detachment, etc. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Time to Nd:YAG posterior capsulotomy
Временное ограничение: Up to 3 years
|
Time from cataract surgery to Nd:YAG laser posterior capsulotomy. Participants without capsulotomy will be censored at their last follow-up visit. Cumulative probability of capsulotomy over time will be estimated using Kaplan-Meier survival analysis. |
Up to 3 years
|
Соавторы и исследователи
Спонсор
Публикации и полезные ссылки
Общие публикации
- Lin H, Zhang J, Jin A, Zhang Y, Zhang Y, Jin L, Xu Y, Xie X, Qiu X, Dai B, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Power Calculation in Highly Myopic Eyes: Secondary Analysis of a Randomized Clinical Trial. JAMA Ophthalmol. 2025 May 1;143(5):373-381. doi: 10.1001/jamaophthalmol.2025.0110.
- Lin H, Zhang J, Zhang Y, Jin A, Zhang Y, Jin L, Xu Y, Xie X, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Randomized Clinical Trial. JAMA Ophthalmol. 2024 Aug 1;142(8):708-715. doi: 10.1001/jamaophthalmol.2024.2215.
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 2021KYPJ128
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .