- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05161520
Impacto da implantação do anel de tensão capsular na posição da lente intraocular
Impacto da implantação do anel de tensão capsular na inclinação e descentração da lente intraocular em pacientes com catarata e alta miopia: um estudo controlado randomizado
This is a randomized controlled trial to investigate the effect of capsular tension ring (CTR) implantation on intraocular lens (IOL) tilt and decentration in cataract patients with high myopia.
Visão geral do estudo
Status
Condições
Descrição detalhada
Exact positioning and alignment of the IOL with the visual axis are the prerequisites of high-quality visual performance after cataract surgery. A certain degree of IOL tilt and decentration occur after uneventful cataract surgery, most of which are clinically tolerant. However, the relatively large capsular bag volume, zonular weakness, and vitreous liquefaction in cataract patients with high myopia may increase the IOL position instability, such as tilt, decentration and even dislocation, leading to the deterioration of visual function. Thus, how to improve the long-term stability of IOL position in high myopic cataract patients is an urgent issue to be addressed.
Previous studies have shown that CTR implantation during cataract surgery can increase the IOL stability in patients with normal axial length; however, its impact on IOL position of cataract patients with high myopia remains unclear.
In this randomized clinical trial, patients who meet the inclusion criteria will be divided into three layers according to the axial length:
(1)26mm≤AL<28mm (2)28mm≤AL<30mm (3)AL≥30mm
We are going to recruit 186 patients in total, with 62 patients in each layer. Patients on each layer will be randomly divided into experimental group (CTR implantation) and control group (only IOL implantation). If both eyes of a patient meet the inclusion criteria, only the first operated eye is included in the statistics analysis.
All included patients will be followed up at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively. Visual acuity, IOL tilt, IOL decentration, posterior capsule attachment with IOL, anterior capsule contraction, posterior capsular opacification, and visual quality will be measured and compared between the experimental group and the control group at different timepoints.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510060
- Zhongshan Ophthalmic Center, Sun Yat-sen University
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- > 18 years old;
- axis length≥26mm;
- Visually significant cataract;
- The patient is willing and able to complete all necessary follow-ups and examinations.
Exclusion Criteria:
- Intraoperative or postoperative complications: such as intraoperative posterior capsular rupture, zonular dehiscence, secondary glaucoma, endophthalmitis, etc.;
- Other ocular comorbidity: such as keratopathy, glaucoma, uveitis, retinopathy, lens dislocation and ocular trauma, etc.;
- History of intraocular surgery;
- Severe systemic diseases: such as severe hypertension, diabetes, heart disease, Alzheimer's, Parkinson, etc.;
- Any condition that the study physician considers to be an impediment to the clinical trial.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Os pacientes com LIO mais CTR serão submetidos à facoemulsificação combinada com implante de LIO e CTR.
|
Device: CTR (276001G; OPHTEC BV, Netherlands) Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, a capsular tension ring is implanted in the capsular bag and then IOL is implanted. |
|
Comparador de Placebo: Pacientes com LIO única passarão por facoemulsificação combinada com implante de LIO.
|
Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, IOL is implanted in the capsular bag. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
IOL dencentration
Prazo: 3 months after surgery
|
Measured by anterior segment OCT (CASIA2) |
3 months after surgery
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
IOL dencentration
Prazo: Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 6 months, 1 year, 3 year after surgery
|
|
IOL tilt
Prazo: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Anterior capsule contraction
Prazo: Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Compare the area of anterior capsule opening recorded by slit lamp photograph and analyzed by Image J software. |
Baseline, 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsule attachment with IOL
Prazo: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by anterior segment OCT (CASIA2) and analyzed by Image J software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Posterior capsular opacification
Prazo: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Recorded by slit lamp photograph and analyzed by EPCO2000 analysis software. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
BCVA
Prazo: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
BCVA is evaluated with ETDRS visual acuity chart. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Optical quality
Prazo: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by OPD-SCAN III. |
Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Visual function
Prazo: 3 months, 6 months, 1 year, 3 year after surgery
|
Measured by visual function assessment questionnaires. |
3 months, 6 months, 1 year, 3 year after surgery
|
|
Incidence of postoperative complications
Prazo: 1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
IOL dislocation, retinal detachment, etc. |
1 week, 1 month, 3 months, 6 months, 1 year, 3 year after surgery
|
|
Time to Nd:YAG posterior capsulotomy
Prazo: Up to 3 years
|
Time from cataract surgery to Nd:YAG laser posterior capsulotomy. Participants without capsulotomy will be censored at their last follow-up visit. Cumulative probability of capsulotomy over time will be estimated using Kaplan-Meier survival analysis. |
Up to 3 years
|
Colaboradores e Investigadores
Patrocinador
Publicações e links úteis
Publicações Gerais
- Lin H, Zhang J, Jin A, Zhang Y, Zhang Y, Jin L, Xu Y, Xie X, Qiu X, Dai B, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Power Calculation in Highly Myopic Eyes: Secondary Analysis of a Randomized Clinical Trial. JAMA Ophthalmol. 2025 May 1;143(5):373-381. doi: 10.1001/jamaophthalmol.2025.0110.
- Lin H, Zhang J, Zhang Y, Jin A, Zhang Y, Jin L, Xu Y, Xie X, Tan X, Luo L, Liu Y. Capsular Tension Ring Implantation for Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Randomized Clinical Trial. JAMA Ophthalmol. 2024 Aug 1;142(8):708-715. doi: 10.1001/jamaophthalmol.2024.2215.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2021KYPJ128
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .