Continuous Glucose Sensing at the Site of Subcutaneous Insulin Administration
Continuous Glucose Sensing at the Site of Subcutaneous Insulin Administration: Evaluation of a Novel Single-Port Treatment Approach in Type 1 Diabetic Patients During a 1-Day Stay in a Clinical Research Center and a 6-Day Period at Home
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
The treatment of type 1 diabetes usually comprises the measurement of glucose in blood obtained by finger pricking and the administration of insulin via subcutaneous bolus injection or continuous subcutaneous infusion.
This study seeks to test a new treatment approach where glucose sensing and insulin administration are combined and performed at a single subcutaneous tissue site (single-port treatment approach). A single-port device consisting of a continuous glucose sensor and an insulin infusion cannula is inserted into the subcutaneous tissue of 10 type-1 diabetes patients and used for insulin infusion and simultaneous glucose sensing over a 7-day period. The performance of the single-port device is assessed by comparing the obtained glucose readings with those of a blood glucose meter and an additionally worn control sensor.
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Styria
-
Graz, Styria, Austria, A-8036
- Medical University of Graz
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- 18 to 65 years of age, both inclusive
- Type 1 diabetes treated with Continuous Subcutaneous Insulin Infusion (CSII)
- HbA1C < 10%
- Signed informed consent before any study-related activities
Exclusion Criteria:
- Severe acute diseases
- Clinically overt diabetic complications
- Mental incapacity, unwillingness or language barriers precluding adequate understanding or co-operation
- Taking of any vasoactive substances or anticoagulation medication
- Diseases of the skin which could interfere with application of the catheters and Sensors as judged by the investigator
- Pregnancy, breastfeeding, intention of becoming pregnant or not using adequate contraception.
- Increased tendency towards development of hypoglycaemia
- Any disease or condition which the investigator or treating physician feels would interfere with the trial or the safety of the subject
- Concurrent participation in another study
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: glucose sensing and insulin delivery
Subcutaneous insulin delivery with an insulin pump plus glucose sensing with a continuous glucose sensor placed at the site of subcutaneous insulin delivery. In parallel, capillary glucose determinations using a conventional glucose meter as well as glucose sensing in subcutaneous, insulin-unexposed tissue using a continuous glucose sensor. |
Subcutaneous insulin (100 U/ml, NovoRapid®; Novo Nordisk, Bagsvaerd, Denmark) delivery with an insulin pump (Vibe-TM; Animas Corp., West Chester, PA, USA) and an insulin infusion cannula (SOF-SET MICRO QR 6mm; Medtronic MiniMed, USA) placed at the same site as the continuous glucose sensor.
Glucose sensing with a continuous glucose sensor (Dexcom G4 Platinum Sensor; Dexcom Inc., San Diego, USA) placed at the site of subcutaneous insulin delivery.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Mean absolute relative difference between sensor readings and capillary glucose readings
Periodo de tiempo: 7 days
|
Mean absolute relative differences calculated by determining the mean of the absolute value of the percentage difference between paired sensor and capillary glucose concentration
|
7 days
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Investigadores
Investigadores
- Investigador principal: Thomeas R Pieber, MD, Medical University of Graz, Internal Medicine, Endocrinology and Metabolism
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- Single-Port@Home-01
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .