Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Comparison of NeuroEXPLORER PET/CT Versus Standard-of-care PET/CT of the Head and Neck Region.

14 de mayo de 2026 actualizado por: prof. dr. Koen Van Laere

Prospective Comparison of Ultra-high Resolution NeuroExplorer PET/CT Versus Standard-of-care PET/CT of the Head and Neck Region

The goal of this clinical study is to compare the current standard-of-care PET/CT scanner with the new NeuroEXPLORER PET/CT, with the aim of demonstrating the added diagnostic value of the new scanner. As this is the first device of its kind in Europe, the study will also evaluate the safety and general feasibility of the NeuroEXPLORER system for head and neck PET studies.

Due to to its high resolution, the NeuroEXPLORER enables an accurate investigation of areas up to 20 times smaller than what can be visualized with standard clinical PET scanners, providing images with a very high level of detail. This scanner is specifically designed for imaging the brain, spinal cord, and neck region, to support the diagnosis and monitoring of neurological, psychiatric, and other disorders in the head and neck.

The main questions this study aims to answer are:

  • Does the NeuroEXPLORER provide more detailed information with better diagnostic quality compared to standard clinical PET/CT scans for head and neck disorders?
  • Is the NeuroEXPLORER system safe and effective in performing head and neck studies?

Participants will:

  • receive clear information about the study, including its organization, possible risks, and potential benefits. Based on this, they will be able to give their informed consent by signing an informed consent form before the study begins.
  • visit the clinic (UZ Leuven) once for two consecutive PET/CT scans: first the prescribed clinical scan, followed by a shorter scan with the NeuroEXPLORER.
  • before the start of the regular PET/CT scan, have a small catheter placed in a blood vessel in the forearm. Through this, a tracer will be administered. A tracer is a small amount of slightly radioactive material that helps to produce images of processes inside the body. Depending on the tracer used, the PET/CT scan may start immediately or after a short waiting period.
  • lie on their back on the scanner bed for 10 to 30 minutes during the clinical scan.
  • after the clinical scan, undergo a 15-20 minute scan on the NeuroEXPLORER.
  • leave the hospital after completing both scans.
  • afterwards, be asked whether they experienced any discomfort during the study. In addition, they will receive a one-time follow-up phone call within a week after the scan to check if they experienced any discomfort in the days following the study.

Descripción general del estudio

Estado

Inscripción por invitación

Condiciones

Intervención / Tratamiento

Tipo de estudio

Intervencionista

Inscripción (Estimado)

1600

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Vlaams-Brabant
      • Leuven, Vlaams-Brabant, Bélgica, 3000
        • UZ Leuven

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

Sí

Descripción

Inclusion Criteria:

  • All subjects referred for standard-of-care PET in the indications for the substudies are eligible.

Exclusion Criteria:

  • Subject is unwilling to avoid unusual, unaccustomed, or strenuous physical activity beginning 4 days prior to tracer injection up to 1 day after tracer injection.

    • Subject does not understand the study procedures.
    • Subject is unwilling or unable to perform all of the study procedures or is considered unsuitable in any way by the principal investigator.
    • Subject has had exposure to ionizing radiation (> 1 mSv) in other research studies within the last 12 months.
    • Subject does not agree that incidental findings are communicated to the general practitioner and to the participant him/herself.
    • Incapacitated patients that cannot give consent by themselves (in particular for substudies 1-3 in neurodegeneration).

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: single arm: PET/CT comparison
All participants undergo a scan on both PET/CT systems. First the Standard-of-care PET/CT and immediately after a scan on the NeuroEXPLORER.
This PET/CT is the routinely used clinical PET/CT scan
Otros nombres:
  • GE MI4 PET/CT
  • Siemens Vision X PET/CT
This is the new ultra-high resolution PET/CT scan

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Difference in diagnostic accuracy and/or diagnostic confidence of ultra-high resolution PET/CT compared to standard PET/CT and validated against clinical follow-up, or pathological/surgical outcomes in neurodegenerative disorders.
Periodo de tiempo: From enrollment until two weeks after the scan
For the neurodegenerative indications (n=1000 subjects), standard-of-care (SOC) and ultra-high-resolution (UHR) PET images will be interpreted by three blinded nuclear medicine physicians using standardized MIM software workflows. Standard clinical criteria by the most recent EANM/SNMMI guidelines will be used for interpretation, supplemented by predefined new features unique to UHR images. Quantitative metrics, including standardized uptake values ratio (SUVR) and z-scores will be recorded in cortical regions and small nuclei of interest by semiquantitative region-based analysis based on a UHR brain atlas and normative database. Standard of truth will be the final clinical diagnosis established by expert memory clinical specialists at least 6 months after PET, based on MRI, SOC PET and fluid biomarkers
From enrollment until two weeks after the scan
Difference in diagnostic accuracy and/or diagnostic confidence of ultra-high resolution PET/CT compared to standard PET/CT and validated against clinical follow-up, or pathological/surgical outcomes in head and neck cancer.
Periodo de tiempo: From enrollment until two weeks after study visit
Lesion detection/delineation and localization performance of the UHR vs. SOC PET will be compared by three blinded expert readers. Images will be co-registered with MRI where available for anatomical precision. Image quantification (semi-quantitative analysis) will include measurement of target-to-background ratio and lesion SUVmax. Standard of truth will be the combination of surgical/histopathological findings and biochemical follow-up.
From enrollment until two weeks after study visit
Comparison of the sensitivity, specificity and accuracy of ultra-high resolution PET vs. standard-of-care PET for the diagnosis of vasculitis and giant cell arteritis, using clinical and pathological confirmation as the benchmark.
Periodo de tiempo: From enrollment until two weeks after study visit
UHR and SOC PET scans will be analyzed by three nuclear medicine physicians. Vascular FDG uptake will be assessed by scoring the presence and intensity of uptake in various arterial segments. Semiquantitative metrics like SUVmax or target-to-background ratio will be obtained. Standard of truth will be the combination of clinical criteria and pathological biopsy confirmation.
From enrollment until two weeks after study visit

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Safety and feasibility of ultra-high resolution PET/CT (MDR generic masterprotocol EUDAMED CIV-25-06-053398)
Periodo de tiempo: From enrollment until 1 week after the scan
Any device specific adverse events (ADE or SADE), including performance parameters will be tracked. PROM (patient reported outcome measures) and patient tolerability will be monitored by a questionnaire taken immediately and one week (phone call) after the study investigation.
From enrollment until 1 week after the scan
Quality of life (QOL) questionnaire
Periodo de tiempo: From enrollment until one year after the study visit
Change in health-related quality of life will be evaluated using the EQ-5D-5L (EuroQol) questionnaire. The questionnaire will be administered at baseline and at one year after the study visit.
From enrollment until one year after the study visit
Impact on decision-making
Periodo de tiempo: From enrollment until 1 year after study visit
Clinical impact will be quantified by the absolute number and proportion of cases in which UHR PET leads to a change in diagnosis, diagnostic confidence, management recommendation, lesion detection, lesion localization, or reader-rated clinical impact compared with standard-of-care PET.
From enrollment until 1 year after study visit

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

30 de septiembre de 2025

Finalización primaria (Estimado)

31 de agosto de 2030

Finalización del estudio (Estimado)

31 de agosto de 2030

Fechas de registro del estudio

Enviado por primera vez

27 de abril de 2026

Primero enviado que cumplió con los criterios de control de calidad

14 de mayo de 2026

Publicado por primera vez (Actual)

19 de mayo de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

19 de mayo de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

14 de mayo de 2026

Última verificación

1 de mayo de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • CIV-25-06-053414

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

SÍ

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .