Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Measuring Blood Vessel Density in the Optic Nerve of Multiple Sclerosis Patients With OCTA

1 de junio de 2026 actualizado por: Sarah Abdul Fattah Saad, Fayoum University

Quantitative OCT Angiography Differences in Optic Nerve Vascular Density in Multiple Sclerosis: A Case-Control Study

The goal of this observational study is to learn about the effect of multiple sclerosis on the blood flow of the optic nerve of affected patients compared to normal subjects by OCTA. The main question it aims to answer is:

  1. Does MS change the blood flow in the optic nerve?
  2. If it does, can measuring this blood flow be used as a simple sign (a biomarker) to help doctors understand and manage MS?

We used a quick and painless eye scan called Optical Coherence Tomography Angiography (OCTA). This special scan takes detailed pictures of the blood vessels in the optic nerve without needing any injections. We performed this scan on two groups of people: one group with MS and one group without MS, and then compare the results.

In simple terms, why is this important? If we can show that MS affects the optic nerve blood vessels, it could give us a new, quick way to monitor the disease and see how it is progressing, just by doing a simple eye scan.

Descripción general del estudio

Estado

Terminado

Condiciones

Intervención / Tratamiento

Descripción detallada

The optic nerve is like the main cable that carries visual information from the eye to the brain. In Multiple Sclerosis (MS), the body's immune system mistakenly attacks the protective covering (called myelin) around nerve fibers, including those in the optic nerve. This often causes a condition called optic neuritis, which can lead to vision loss.

While we know MS damages the nerve fibers, we are now trying to understand how it affects the blood vessels that supply oxygen and nutrients to the optic nerve. Are these blood vessels damaged as well? Does reduced blood flow contribute to the nerve damage?

2. The Technology We Are Using

This study uses a advanced, non-invasive imaging technology called Optical Coherence Tomography Angiography (OCTA).

What it does: The OCTA machine uses a safe, dim light beam to scan the optic nerve and macula. It works like a microscopic radar for blood vessels, allowing us to create very detailed, high-resolution 3D maps of the blood flow in the retina and optic nerve without any needles or injections.

What we measure: From these maps, we can quantitatively analyze the vessel density which is a percentage that tells us how much of a specific area is filled with functioning blood vessels. We will focus this measurement on the Radial Peripapillary Capillaries, which are the blood vessels that directly supply the optic nerve head.

3. The Purpose and Potential Impact of This Research

The main goal of this study is to determine if the blood vessel density in the optic nerve is a reliable biological marker (or biomarker) for MS.

A biomarker is an objective, measurable sign of a medical condition. If we can prove that changes in optic nerve blood flow are a consistent marker of MS, it could provide us with:

A new tool to help understand the disease activity in an individual.

A quick and painless way to potentially monitor how the disease is changing over time and whether treatments are effectively protecting the nervous system.

By comparing these detailed OCTA measurements between participants with and without MS, we hope to better understand the role of blood flow in the disease and contribute to improved future care for people living with MS.

Tipo de estudio

De observación

Inscripción (Actual)

54

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Faiyum Governorate
      • Al Fayyum, Faiyum Governorate, Egipto, 63514
        • Fayoum University hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

Sí

Método de muestreo

Muestra no probabilística

Población de estudio

This case-control study enrolled two groups: group 1; 26 adults with a clinically definite diagnosis of Multiple Sclerosis (Cases) and group 2; 28 age- and sex-matched healthy adults with no history of neurological or significant ocular disease (Controls).

Descripción

Inclusion Criteria:

  • group 1; patients with multiple sclerosis with optic neuritis.
  • group 2; normal healthy age matched controls

Exclusion Criteria:

  • Other optic nerve diseases as glaucoma, papilledema or conginetal anomalies.
  • Other macular diseases as AMD, CSR, scars …
  • Errors of refraction outside +4 and -6 D range.
  • Media opacity as cataracts or corneal opacities that may interfere with the quality of scans.
  • Signal strength index less than 4\10.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Multiple Sclerosis (MS) Cohort
26 eyes of patients with clinically definite MS
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
Healthy Control Cohort
28 eyes of age- and sex-matched normal subjects
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
vessel density of the optic nerve head and peripapillary region measured by OCTA
Periodo de tiempo: Baseline
Difference in microvascular vessel density, as measured by Optical Coherence Tomography Angiography (OCTA), in the optic nerve head and peripapillary region between patients with Multiple Sclerosis and healthy controls. Analysis will include the whole disc area, inside the disc, and individual quadrants.
Baseline

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
RNFL thickness
Periodo de tiempo: Baseline
Retinal Nerve Fiber Layer (RNFL) thickness, measured in micrometers, for the superior and inferior hemispheres of the optic nerve head.
Baseline
GCC thickness
Periodo de tiempo: Baseline
The thickness of the macular Ganglion Cell Complex (GCC) was measured in micrometers for the superior and inferior hemispheres. These measurements were then analyzed by the device's proprietary software to calculate the Focal Loss Volume (FLV) and Global Loss Volume (GLV) indices.
Baseline

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

5 de enero de 2025

Finalización primaria (Actual)

3 de agosto de 2025

Finalización del estudio (Actual)

3 de agosto de 2025

Fechas de registro del estudio

Enviado por primera vez

26 de septiembre de 2025

Primero enviado que cumplió con los criterios de control de calidad

1 de junio de 2026

Publicado por primera vez (Actual)

5 de junio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

5 de junio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

1 de junio de 2026

Última verificación

1 de septiembre de 2025

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • R687

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

producto fabricado y exportado desde los EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .