Measuring Blood Vessel Density in the Optic Nerve of Multiple Sclerosis Patients With OCTA
Quantitative OCT Angiography Differences in Optic Nerve Vascular Density in Multiple Sclerosis: A Case-Control Study
The goal of this observational study is to learn about the effect of multiple sclerosis on the blood flow of the optic nerve of affected patients compared to normal subjects by OCTA. The main question it aims to answer is:
- Does MS change the blood flow in the optic nerve?
- If it does, can measuring this blood flow be used as a simple sign (a biomarker) to help doctors understand and manage MS?
We used a quick and painless eye scan called Optical Coherence Tomography Angiography (OCTA). This special scan takes detailed pictures of the blood vessels in the optic nerve without needing any injections. We performed this scan on two groups of people: one group with MS and one group without MS, and then compare the results.
In simple terms, why is this important? If we can show that MS affects the optic nerve blood vessels, it could give us a new, quick way to monitor the disease and see how it is progressing, just by doing a simple eye scan.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
The optic nerve is like the main cable that carries visual information from the eye to the brain. In Multiple Sclerosis (MS), the body's immune system mistakenly attacks the protective covering (called myelin) around nerve fibers, including those in the optic nerve. This often causes a condition called optic neuritis, which can lead to vision loss.
While we know MS damages the nerve fibers, we are now trying to understand how it affects the blood vessels that supply oxygen and nutrients to the optic nerve. Are these blood vessels damaged as well? Does reduced blood flow contribute to the nerve damage?
2. The Technology We Are Using
This study uses a advanced, non-invasive imaging technology called Optical Coherence Tomography Angiography (OCTA).
What it does: The OCTA machine uses a safe, dim light beam to scan the optic nerve and macula. It works like a microscopic radar for blood vessels, allowing us to create very detailed, high-resolution 3D maps of the blood flow in the retina and optic nerve without any needles or injections.
What we measure: From these maps, we can quantitatively analyze the vessel density which is a percentage that tells us how much of a specific area is filled with functioning blood vessels. We will focus this measurement on the Radial Peripapillary Capillaries, which are the blood vessels that directly supply the optic nerve head.
3. The Purpose and Potential Impact of This Research
The main goal of this study is to determine if the blood vessel density in the optic nerve is a reliable biological marker (or biomarker) for MS.
A biomarker is an objective, measurable sign of a medical condition. If we can prove that changes in optic nerve blood flow are a consistent marker of MS, it could provide us with:
A new tool to help understand the disease activity in an individual.
A quick and painless way to potentially monitor how the disease is changing over time and whether treatments are effectively protecting the nervous system.
By comparing these detailed OCTA measurements between participants with and without MS, we hope to better understand the role of blood flow in the disease and contribute to improved future care for people living with MS.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
Faiyum Governorate
-
Al Fayyum, Faiyum Governorate, Egito, 63514
- Fayoum University hospital
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- group 1; patients with multiple sclerosis with optic neuritis.
- group 2; normal healthy age matched controls
Exclusion Criteria:
- Other optic nerve diseases as glaucoma, papilledema or conginetal anomalies.
- Other macular diseases as AMD, CSR, scars …
- Errors of refraction outside +4 and -6 D range.
- Media opacity as cataracts or corneal opacities that may interfere with the quality of scans.
- Signal strength index less than 4\10.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Número de grupos/coortes
Coortes e Intervenções
Grupo / CoorteGrupo / Coorte |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Multiple Sclerosis (MS) Cohort
26 eyes of patients with clinically definite MS
|
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
|
|
Healthy Control Cohort
28 eyes of age- and sex-matched normal subjects
|
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
vessel density of the optic nerve head and peripapillary region measured by OCTA
Prazo: Baseline
|
Difference in microvascular vessel density, as measured by Optical Coherence Tomography Angiography (OCTA), in the optic nerve head and peripapillary region between patients with Multiple Sclerosis and healthy controls.
Analysis will include the whole disc area, inside the disc, and individual quadrants.
|
Baseline
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
RNFL thickness
Prazo: Baseline
|
Retinal Nerve Fiber Layer (RNFL) thickness, measured in micrometers, for the superior and inferior hemispheres of the optic nerve head.
|
Baseline
|
|
GCC thickness
Prazo: Baseline
|
The thickness of the macular Ganglion Cell Complex (GCC) was measured in micrometers for the superior and inferior hemispheres.
These measurements were then analyzed by the device's proprietary software to calculate the Focal Loss Volume (FLV) and Global Loss Volume (GLV) indices.
|
Baseline
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- R687
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .