Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Improving Neonatal Hip Screening With Artificial Intelligence

26 de agosto de 2026 actualizado por: Murdoch Childrens Research Institute

Improving Screening for Developmental Dysplasia of the Hip Using Artificial Intelligence Ultrasound Scans in Neonates: A Pilot Study

The goal of this trial is to pilot a portable ultrasound device that uses artificial intelligence to screen for hip dysplasia. Researchers will gather data to understand the feasibility of performing a larger trial in birthing hospitals. It will also seek to collect initial data on how well the scan compares to the standard hip screening performed soon after birth.

Participants will:

  • Have the portable ultrasound performed on their baby before they are discharged from hospital
  • Have a diagnostic ultrasound performed on their baby at 6-weeks of age
  • Complete a short questionnaire about the experience of having the measurement performed on their baby

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Descripción detallada

A recent study by our team showed that at The Royal Women's Hospital, Melbourne, screening at birth using the standard combination of neonatal hip examination and risk-based referral for ultrasound failed to detect 52% (n=100) of cases of Developmental Dysplasia of the Hip (DDH) and that 98.5% (n=2,637) of infants undergoing a screening ultrasound, due to perceived increased risk, do not have DDH. Further, this research team replicated in a regional setting at University Hospital, Geelong in Victoria (n=1,207), that 55.6% of cases of DDH were missed, and of those sent for diagnostic ultrasound scans 92.5% did not have DDH (unpublished data). Together, this means many infants are being scanned, but an unacceptably high proportion of cases are still being missed.

Late detected dysplasia is often resistant to conservative treatment. This form of dysplasia is unpredictable in its presentation and may require surgical intervention to obtain a contained and stable joint. Such patients are at a higher risk of developing degenerative hip disease in early adult life and can suffer considerable disability, often failing to reach their full potential. Thus, many initiatives have been taken to improve our current screening programs, including clinical education programs, streamlined access, and incorporation of hip examinations into child health assessments. However, none of these initiatives has effectively reduced the rate of late detection of dysplasia. Despite selective screening protocols being in place, the incidence of late-diagnosed DDH has increased in South Australia, showing a significant rise from 0.22 per 1000 live births (1988-2003) to 0.77 per 1000 live births (2003-2009).

One part of the solution is optimising screening protocols for DDH in existing care models. A possible solution is utilising artificial intelligence to aid in screening decisions. One such new tool is the Exo Iris, a portable ultrasound device supported by real-time AI-augmented analysis to screen for hip dysplasia. Importantly, use of this device does not require extensive training and could be performed by midwives or paediatricians in standard neonate hip examinations. Initial work has shown that AI could successfully identify the standard plane, make measurements, and classify the hip as normal or abnormal. Scans are simple to conduct, add little time to the overall consultation and are non-invasive without the use of ionising radiation. Importantly, non-experts can easily be trained to use the technology; they are cost-effective and can be used in any clinical environment connected to a standard tablet.

Initial Canadian data suggests that DDH detection rates suggests that artificial intelligence (AI) analysis for hip dysplasia are on par with orthopaedic specialists. Of the infants flagged for follow-up there were 6 subsequently referred to specialist clinics after repeat scan and all were treated for DDH (5 harnessed, 1 surgical intervention). Of these the six infants detected, only two presented with well documented risk factors for increased risk of DDH (female sex, Indigenous, breech, family history), which may not have been detected without initial portable ultrasound screening.

Further to this, Retuve is a new open-source software tool that uses AI-analysis to measures standard indices on hip ultrasound images collected from any manufacturer's ultrasound probe, which can help users make hip screening decisions. This platform generates novel imaging parameters beyond current standards that may also be helpful in further understanding undetected late presentations. However, as this is a relatively new tool there has been little research to fully evaluate its performance and its potential utility as a screening tool.

There is clear scope for this technology to revolutionise screening in Australia by reducing the number of cases of DDH missed and the number of costly conventional ultrasound scans; however, there is limited data assessing the feasibility and accuracy of the new AI analysis strategies for DDH screening in the context of neonatal screening. To date, although the Exo Iris and embedded hip AI software is indicated for use in infants 0-6 months there is a dearth of data examining neonates, and no data exists evaluating it in the context of selective neonatal screening.

This study will provide foundational pilot evidence on the accuracy and feasibility of using the Exo Iris probe and an alternate AI software platform as part of standard neonatal screening. In addition to this, long-term follow-up as part of the VicHip parent study will aid in understanding potential parameters associated with missed presentations. To do this, 100 infants will be recruited from Monash Medical Centre, Victoria, Australia and will undergo both the AI-ultrasound scan that will be analysed both by the embedded software and Retuve and results from the AI analyses will be compared to a 6-week full diagnostic ultrasound.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

100

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  1. Enrolled in the Victorian Hip Dysplasia Registry (VicHip) study
  2. Infant born at term (≥37 weeks gestation)
  3. Infant and caregiver admitted to the post-natal ward
  4. Caregivers indicate they are willing to attend a 6-week ultrasound
  5. Caregivers can provide a signed and dated informed consent form and is a legally acceptable representative capable of understanding the informed consent document and providing consent on the infant's behalf.

Exclusion Criteria:

  1. Any known congenital anomalies in the infant precluding examination of the hips
  2. Any known congenital neuromuscular conditions in the infant

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Poner en pantalla
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: All active participants
All infants will undergo the AI-augmented ultrasound measure
The hip ultrasound is performed using a handheld device (Exo Iris) that is a pocket-sized ultrasound probe and is run through an application on an IoS (Apple mobile) operation system. A real-time algorithm detects and records the anatomical landmarks.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Feasibility of the AI-ultrasound method as determined by a study-specific questionnaire administered to care givers at Day 1
Periodo de tiempo: Day 1
Caregiver perspectives will be captured via a study-specific questionnaire administered at Day 1 and this will enable determination of the feasibility of the AI-ultrasound method.
Day 1
Number of infants unable to be scanned with the AI ultrasound
Periodo de tiempo: Day 1
The proportion of infants unable to be successfully scanned with the AI-ultrasound will be calculated.
Day 1
Reasons for failure to obtain AI ultrasound scan as determined by the performing research assistant
Periodo de tiempo: Day 1
The reasons why infants were unable to be scanned as determined by the research assistant performing the AI scan will be documented as follows: Unsettled baby, technical failure, body habitus or other.
Day 1
Proportion of infants lost to follow-up between the AI-ultrasound and 6-week (corrected) diagnostic scan
Periodo de tiempo: Week 6
The proportion of infants that had an initial AI scan at Day 1 but did not return for a scan at Week 6 will be calculated.
Week 6

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Specificity of AI-ultrasound device as determined by comparison of the geometric measures (femoral head coverage and alpha angle) and expert reviews between the Day 1 and Week 6 scans
Periodo de tiempo: Day 1, Week 6
AI-ultrasound results will be compared to 6-week diagnostic ultrasound imaging to calculate specificity ([number of true negative cases detected/(number of false positive cases detected + number of true negatives cases detected] X 100). Hips will be classified according to the AI-recommendations, "unremarkable" i.e. no follow-up required or "follow-up recommended" to define negative and positive cases; those that receive an "unremarkable" classification will be defined as negative cases, and those that receive a "follow-up recommended" scan will be considered as positive cases for the reliability calculations. Diagnosis will be defined from the 6-week ultrasound scan and will be defined by both expert conclusion and geometric measures (femoral head coverage and alpha angle). Calculations will be performed at both the hip and individual level.
Day 1, Week 6
Sensitivity of AI-ultrasound measure determined by comparison of the geometric measures (femoral head coverage and alpha angle) and expert reviews between the Day 1 and Week 6 scans
Periodo de tiempo: Day 1, Week 6
AI-ultrasound results will be compared to 6-week diagnostic ultrasound imaging to calculate sensitivity ([number of true positive cases detected/(number of true positive cases detected + number of false negative cases detected)] X 100). Hips will be classified according to the AI-recommendations, "unremarkable" i.e. no follow-up required or "follow-up recommended" to define negative and positive cases; those that receive an "unremarkable" classification will be defined as negative cases, and those that receive a "follow-up recommended" scan will be considered as positive cases for the reliability calculations. Diagnosis will be defined from the 6-week ultrasound scan and will be defined by both expert conclusion and geometric measures (femoral head coverage and alpha angle). Calculations will be performed at both the hip and individual level.
Day 1, Week 6
The correlation between the alpha angle degree as reported by the AI-ultrasound analysis and expert analysis of the 6-week diagnostic ultrasound scan
Periodo de tiempo: Day 1, Week 6
Dependent on the distribution of the data Pearsons or Spearman's Rho correlation coefficients will be reported.
Day 1, Week 6
The correlation between the percentage femoral head coverage as reported by the AI-ultrasound analysis and expert analysis of the 6-week diagnostic ultrasound scan
Periodo de tiempo: Day 1, Week 6
Dependent on the distribution of the data Pearsons or Spearman's Rho correlation coefficients will be reported.
Day 1, Week 6

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Difference in specificity of standard neonatal screening and the AI-ultrasound scan to discriminate for DDH
Periodo de tiempo: Day 1
The specificity of standard neonatal screening and the AI-ultrasound screening will be compared.
Day 1
Difference in specificity of Retuve and the AI-ultrasound scan to discriminate for DDH
Periodo de tiempo: Day 1
The specificity of an alternate AI-analysis platform will be compared to the AI-ultrasound scan results.
Day 1

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Investigadores

  • Investigador principal: Brian Loh, MBBS BBiomedSc FRACS FAOrthoA, Murdoch Children's Research Institute & Monash Health

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de agosto de 2026

Finalización primaria (Estimado)

1 de febrero de 2027

Finalización del estudio (Estimado)

1 de marzo de 2027

Fechas de registro del estudio

Enviado por primera vez

5 de agosto de 2026

Primero enviado que cumplió con los criterios de control de calidad

26 de agosto de 2026

Publicado por primera vez (Actual)

31 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

31 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

26 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 124710

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

SÍ

Descripción del plan IPD

The de-identified data set collected for this analysis of this trial will be available 12 months after publication of the primary outcome. The study protocol and informed consent form will also be available.

Marco de tiempo para compartir IPD

12 months after the publication of data until the data is deleted (at minimum 1 year after the youngest participant turns 25 years of age).

Criterios de acceso compartido de IPD

The data must be obtained from the Murdoch Children's Research Institute. Prior to releasing any data the following are required: a data access agreement must be signed between relevant parties, the Study Management Group must see and approve the data analysis plan describing how the data will be analysed, there must be an agreement around appropriate acknowledgment and any additional costs involved must be covered. Should the Study Management Group be unavailable, this role is delegated to the Murdoch Children's Research Institute. Data will only be shared with a recognized research organisation which has approved the proposed analysis plan.

Tipo de información de apoyo para compartir IPD

  • PROTOCOLO DE ESTUDIO
  • CIF

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

producto fabricado y exportado desde los EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .