Use of Ultrasound Imaging in Confirming Osteopathic Spinal Diagnosis
Investigating Use of Musculoskeletal Ultrasound in Conjunction With Manual Somatic Dysfunction Diagnosis
In the field of Osteopathic Medicine, diagnosis of potential areas of dysfunction are diagnosed by the physician using their hands and expertise in noticing subtle differences in symmetry, tone, swelling etc.. In this study, we propose the use of ultrasound, which is a non invasive imaging technique that requires no radiation exposure, to confirm the diagnosis made with the physician's hands. We believe this will add a layer of objectivity to this diagnosis, in that you have numbers that have been measured to back up the diagnosis made based on feel. In this study, we can confirm whether or not these differences felt are true from an objective standpoint. We will compare patients with dysfunction palpated on manual exam to those with no palpated dysfunction in terms of their median asymmetry when measured using musculoskeletal ultrasound.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
New York
-
Brooklyn, New York, Estados Unidos, 11210
- Leonid Tafler DO Osteopathic Medical Treatment
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Patients of Dr. Leonid Tafler's private practice
Descripción
Inclusion Criteria:
- patients found to have somatic dysfunction on palpation of the spine
Exclusion Criteria:
- patients that decline participation, otherwise no exclusion criteria
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: CASE_CONTROL
- Perspectivas temporales: CROSS_SECTIONAL
Número de grupos/cohortes
Cohortes e Intervenciones
Grupo / CohorteGrupo / Cohorte |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Palpated somated dysfuncion
Patients in this group would be those who were palpated by the Osteopathic Physician and found to have an identifiable somatic dysfunction of the spine on manual exam. These patients then immediately undergo spinal ultrasound to confirm whether or not there is measured asymmetry in the spine. |
Patient will undergo transverse spinal ultrasound of the spinal segment of interest, and the image taken will be measured for the distance from the facet joint on each side to the skin. The absolute value of the difference between these measurements is then recorded as the measured asymmetry. |
|
No Palpated Somatic Dysfunction
Patients with no somatic dysfunction palpated by the osteopathic physician on initial manual examination. |
Patient will undergo transverse spinal ultrasound of the spinal segment of interest, and the image taken will be measured for the distance from the facet joint on each side to the skin. The absolute value of the difference between these measurements is then recorded as the measured asymmetry. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Measured Asymmetry
Periodo de tiempo: Single measurement
|
This is the absolute value of the difference between the measured distance from the left facet joint to the skin, and the right facet joint to the skin. This measurement is obtained from a transverse ultrasound image using the caliper function on the ultrasound machine. |
Single measurement
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Mikhail Volokitin, DO, Touro College of Osteopathic Medicine - Harlem, NY Campus
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- 28463
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .