Use of Ultrasound Imaging in Confirming Osteopathic Spinal Diagnosis
Investigating Use of Musculoskeletal Ultrasound in Conjunction With Manual Somatic Dysfunction Diagnosis
In the field of Osteopathic Medicine, diagnosis of potential areas of dysfunction are diagnosed by the physician using their hands and expertise in noticing subtle differences in symmetry, tone, swelling etc.. In this study, we propose the use of ultrasound, which is a non invasive imaging technique that requires no radiation exposure, to confirm the diagnosis made with the physician's hands. We believe this will add a layer of objectivity to this diagnosis, in that you have numbers that have been measured to back up the diagnosis made based on feel. In this study, we can confirm whether or not these differences felt are true from an objective standpoint. We will compare patients with dysfunction palpated on manual exam to those with no palpated dysfunction in terms of their median asymmetry when measured using musculoskeletal ultrasound.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
New York
-
Brooklyn, New York, Estados Unidos, 11210
- Leonid Tafler DO Osteopathic Medical Treatment
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Patients of Dr. Leonid Tafler's private practice
Descrição
Inclusion Criteria:
- patients found to have somatic dysfunction on palpation of the spine
Exclusion Criteria:
- patients that decline participation, otherwise no exclusion criteria
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: CASE_CONTROL
- Perspectivas de Tempo: CROSS_SECTIONAL
Número de grupos/coortes
Coortes e Intervenções
Grupo / CoorteGrupo / Coorte |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Palpated somated dysfuncion
Patients in this group would be those who were palpated by the Osteopathic Physician and found to have an identifiable somatic dysfunction of the spine on manual exam. These patients then immediately undergo spinal ultrasound to confirm whether or not there is measured asymmetry in the spine. |
Patient will undergo transverse spinal ultrasound of the spinal segment of interest, and the image taken will be measured for the distance from the facet joint on each side to the skin. The absolute value of the difference between these measurements is then recorded as the measured asymmetry. |
|
No Palpated Somatic Dysfunction
Patients with no somatic dysfunction palpated by the osteopathic physician on initial manual examination. |
Patient will undergo transverse spinal ultrasound of the spinal segment of interest, and the image taken will be measured for the distance from the facet joint on each side to the skin. The absolute value of the difference between these measurements is then recorded as the measured asymmetry. |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Measured Asymmetry
Prazo: Single measurement
|
This is the absolute value of the difference between the measured distance from the left facet joint to the skin, and the right facet joint to the skin. This measurement is obtained from a transverse ultrasound image using the caliper function on the ultrasound machine. |
Single measurement
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Mikhail Volokitin, DO, Touro College of Osteopathic Medicine - Harlem, NY Campus
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- 28463
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .