3D Video to Measure Breathing and Breathing-Muscle Activity (KINEVENT)
Non-invasive Measurement of Tidal Volume and Inspiratory Muscle Recruitment Using Three-dimensional Video in Healthy Volunteers Under Incremental Inspiratory Loading: a Pilot Agreement Study
Doctors often need to know how well a patient is breathing. Two things matter: how much air a person moves with each breath, and how hard the breathing muscles are working. Today, measuring these usually requires devices placed on or inside the body, which can be uncomfortable and are not always suitable at the bedside.
This study tests a new way to measure breathing without touching the body. A set of cameras films the surface of the chest and neck and builds a three-dimensional image of how they move during breathing. A computer uses these movements to estimate the amount of air breathed and to detect when the breathing muscles are being used.
The purpose of this study is to check whether the camera-based method is accurate. To do this, the researchers compare it with standard breathing measurements in healthy adult volunteers. During a single session, volunteers breathe normally and then breathe against increasing resistance, which makes breathing a little harder, while the cameras and the standard devices record at the same time.
The study will include 10 healthy volunteers (5 women and 5 men). It does not involve any treatment, and no results are expected to directly benefit the participants. If the method proves accurate, it could later be tested in patients to help monitor breathing in intensive care.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
Estudio Contacto
- Nombre: Guillaume Dumas, MD, PhD
- Número de teléfono: +33 4 76 76 87 79
- Correo electrónico: GDumasgalant@chu-grenoble.fr
Copia de seguridad de contactos de estudio
- Nombre: EVA LATCHIMY
- Número de teléfono: +33 0476767109
- Correo electrónico: MELatchimy@chu-grenoble.fr
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Adult aged 18 years or older
- No known respiratory, cardiovascular, or neurological disease
- Able to understand and perform the requested breathing maneuvers
- Affiliated with a social security scheme (or beneficiary of one)
- Written informed consent signed
Exclusion Criteria:
- Respiratory, thoracic, or chest wall disease or history
- Body mass index ≥ 30 kg/m²
- Inability to perform the maneuvers (understanding, cooperation)
- Pregnant or breastfeeding woman
- Person deprived of liberty by judicial or administrative decision
- Adult under a legal protection measure
- Person unable to express consent
- Participation in an exclusion period of another study
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: Healthy volunteers - incremental inspiratory loading
Healthy adult volunteers undergo a single measurement session. Breathing is recorded simultaneously by a markerless three-dimensional multi-camera system (surface reconstruction of the torso), a calibrated spirometer (reference tidal volume), and surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. After a quiet-breathing reference period, participants breathe against stepwise increasing inspiratory resistances, with a Borg dyspnea rating at each step. Video-estimated tidal volume is compared with spirometry (primary outcome: agreement), and video-derived surface deformation indices are compared with surface electromyography. No treatment is given; there is no individual benefit expected. |
A markerless multi-camera system reconstructs the three-dimensional surface of the torso without contact or skin markers. Surface deformations over the respiratory cycle are used to estimate tidal volume and to derive regional indices of respiratory muscle recruitment (cervical region and lower thoraco-abdominal region). During a single session, recordings are acquired simultaneously with a calibrated spirometer (reference tidal volume) and with surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. The video system is calibrated beforehand on a bench using an artificial lung delivering known volumes. The device is used for measurement only, is non-invasive, and emits no radiation. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Agreement between video-estimated and spirometry-measured tidal volume (bias)
Periodo de tiempo: During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between tidal volume estimated by the three-dimensional video system and tidal volume measured by calibrated spirometry (reference) .The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Error between video and spirometry volume-time curves
Periodo de tiempo: During the single measurement session (approximately 2 hours)
|
Normalized root mean square error (nRMSE, dimensionless) between the continuous volume-time curve from the three-dimensional video system and calibrated spirometry (reference). |
During the single measurement session (approximately 2 hours)
|
|
Correlation between cervical-region video signal and sternocleidomastoid surface EMG
Periodo de tiempo: During the single measurement session (approximately 2 hours)
|
Repeated-measures correlation coefficient (rmcorr, dimensionless, range -1 to 1) between the cervical-region video signal (three-dimensional video system) and the normalized surface electromyography amplitude of the sternocleidomastoid muscle (% of maximal activation). |
During the single measurement session (approximately 2 hours)
|
|
Robustness of video-spirometry agreement and of video volume measurement across inspiratory load levels
Periodo de tiempo: During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between video-estimated and spirometry-measured tidal volume, reported separately for each inspiratory load level. The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Investigadores
Investigadores
- Director de estudio: Guillaume Dumas, MD, PhD, University Grenoble Alps
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
Otros números de identificación del estudio
- 38RC26.0329
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .