3D Video to Measure Breathing and Breathing-Muscle Activity (KINEVENT)
Non-invasive Measurement of Tidal Volume and Inspiratory Muscle Recruitment Using Three-dimensional Video in Healthy Volunteers Under Incremental Inspiratory Loading: a Pilot Agreement Study
Doctors often need to know how well a patient is breathing. Two things matter: how much air a person moves with each breath, and how hard the breathing muscles are working. Today, measuring these usually requires devices placed on or inside the body, which can be uncomfortable and are not always suitable at the bedside.
This study tests a new way to measure breathing without touching the body. A set of cameras films the surface of the chest and neck and builds a three-dimensional image of how they move during breathing. A computer uses these movements to estimate the amount of air breathed and to detect when the breathing muscles are being used.
The purpose of this study is to check whether the camera-based method is accurate. To do this, the researchers compare it with standard breathing measurements in healthy adult volunteers. During a single session, volunteers breathe normally and then breathe against increasing resistance, which makes breathing a little harder, while the cameras and the standard devices record at the same time.
The study will include 10 healthy volunteers (5 women and 5 men). It does not involve any treatment, and no results are expected to directly benefit the participants. If the method proves accurate, it could later be tested in patients to help monitor breathing in intensive care.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Guillaume Dumas, MD, PhD
- Numero di telefono: +33 4 76 76 87 79
- Email: GDumasgalant@chu-grenoble.fr
Backup dei contatti dello studio
- Nome: EVA LATCHIMY
- Numero di telefono: +33 0476767109
- Email: MELatchimy@chu-grenoble.fr
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Adult aged 18 years or older
- No known respiratory, cardiovascular, or neurological disease
- Able to understand and perform the requested breathing maneuvers
- Affiliated with a social security scheme (or beneficiary of one)
- Written informed consent signed
Exclusion Criteria:
- Respiratory, thoracic, or chest wall disease or history
- Body mass index ≥ 30 kg/m²
- Inability to perform the maneuvers (understanding, cooperation)
- Pregnant or breastfeeding woman
- Person deprived of liberty by judicial or administrative decision
- Adult under a legal protection measure
- Person unable to express consent
- Participation in an exclusion period of another study
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Scienza basilare
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Healthy volunteers - incremental inspiratory loading
Healthy adult volunteers undergo a single measurement session. Breathing is recorded simultaneously by a markerless three-dimensional multi-camera system (surface reconstruction of the torso), a calibrated spirometer (reference tidal volume), and surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. After a quiet-breathing reference period, participants breathe against stepwise increasing inspiratory resistances, with a Borg dyspnea rating at each step. Video-estimated tidal volume is compared with spirometry (primary outcome: agreement), and video-derived surface deformation indices are compared with surface electromyography. No treatment is given; there is no individual benefit expected. |
A markerless multi-camera system reconstructs the three-dimensional surface of the torso without contact or skin markers. Surface deformations over the respiratory cycle are used to estimate tidal volume and to derive regional indices of respiratory muscle recruitment (cervical region and lower thoraco-abdominal region). During a single session, recordings are acquired simultaneously with a calibrated spirometer (reference tidal volume) and with surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. The video system is calibrated beforehand on a bench using an artificial lung delivering known volumes. The device is used for measurement only, is non-invasive, and emits no radiation. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Agreement between video-estimated and spirometry-measured tidal volume (bias)
Lasso di tempo: During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between tidal volume estimated by the three-dimensional video system and tidal volume measured by calibrated spirometry (reference) .The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Error between video and spirometry volume-time curves
Lasso di tempo: During the single measurement session (approximately 2 hours)
|
Normalized root mean square error (nRMSE, dimensionless) between the continuous volume-time curve from the three-dimensional video system and calibrated spirometry (reference). |
During the single measurement session (approximately 2 hours)
|
|
Correlation between cervical-region video signal and sternocleidomastoid surface EMG
Lasso di tempo: During the single measurement session (approximately 2 hours)
|
Repeated-measures correlation coefficient (rmcorr, dimensionless, range -1 to 1) between the cervical-region video signal (three-dimensional video system) and the normalized surface electromyography amplitude of the sternocleidomastoid muscle (% of maximal activation). |
During the single measurement session (approximately 2 hours)
|
|
Robustness of video-spirometry agreement and of video volume measurement across inspiratory load levels
Lasso di tempo: During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between video-estimated and spirometry-measured tidal volume, reported separately for each inspiratory load level. The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Direttore dello studio: Guillaume Dumas, MD, PhD, University Grenoble Alps
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 38RC26.0329
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .