Hemodynamic Measurements During Liver Transplantation (OLT)
31 de marzo de 2010 actualizado por: Washington University School of Medicine
Comparing Different Methods For Measurement of Cardiac Output During Orthotopic Liver Transplantation
The purpose of the study is to determine if the less invasive monitors are as reliable for measuring heart function in patients undergoing liver transplantation as the more invasive pulmonary artery.
Descripción general del estudio
Estado
Terminado
Condiciones
Descripción detallada
Pulmonary artery catheter (PAC)is considered the gold standard in monitoring of heart function during orthotopic liver transplantation (OLT).
Placement of PAC is very invasive (it passes thorough the heart chambers and into the pulmonary artery) and its benefits on the outcomes have not been proven.
This study compares two newer FDA approved much less invasive devices to the PAC.
The two new devices assess the heart function based either on the peripheral arterial waveform alone (Vigileo, Edwards Lifesciences)or the combination of peripheral arterial waveform and chemical indicator dilution (LiDCO, Cambridge, UK).
Tipo de estudio
De observación
Inscripción (Actual)
30
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
Missouri
-
St. Louis, Missouri, Estados Unidos, 63110
- Washington University School of Medicine
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años y mayores (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Método de muestreo
Muestra no probabilística
Población de estudio
20 subjects will be enrolled in this observational study in the Liver Transplant Group; 10 patients in the Other Surgery Control Group for a total of 30 subjects.
Patients will be recruited from the Operating Room schedule.
Written, informed consent will be obtained from each subject prior to surgery.
All participants will be informed that they may decline to participate in, or withdraw from, the study at any time.
Descripción
Inclusion Criteria:
- Patients over 18 years of age
- Scheduled for liver transplantation
- Patient undergoing vascular surgery where invasive arterial pressure is indicated (control subjects)
Exclusion Criteria:
- We will exclude patients taking lithium based medication
- Patients who weigh less than 40 kg; AND
- Patients who are pregnant
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
---|---|
Agreement between cardiac output measurements obtained with PAC, Vigileo and LiDCO
Periodo de tiempo: Specific phases of liver transplantation surgery
|
Specific phases of liver transplantation surgery
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Investigador principal: Ivan Kangrga, MD, PhD, Washington University School of Medicine
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Publicaciones Generales
- Vannucci A, Burykin A, Krejci V, Peck T, Buchman TG, Kangrga IM. Postreperfusion cardiac arrest and resuscitation during orthotopic liver transplantation: dynamic visualization and analysis of physiologic recordings. Shock. 2012 Jan;37(1):34-8. doi: 10.1097/SHK.0b013e318239b128.
- Krejci V, Vannucci A, Abbas A, Chapman W, Kangrga IM. Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation. Liver Transpl. 2010 Jun;16(6):773-82. doi: 10.1002/lt.22056.
- Vannucci A, Krejci V, Kangrga I. Performance of Vigileo and LiDCOplus cardiac output monitors during a prolonged cardiac arrest and resuscitation. Eur J Anaesthesiol. 2009 Oct;26(10):885-7. doi: 10.1097/EJA.0b013e32832fa5db. No abstract available.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio
1 de julio de 2007
Finalización primaria (Actual)
1 de enero de 2009
Finalización del estudio (Actual)
1 de marzo de 2010
Fechas de registro del estudio
Enviado por primera vez
16 de mayo de 2008
Primero enviado que cumplió con los criterios de control de calidad
21 de mayo de 2008
Publicado por primera vez (Estimar)
22 de mayo de 2008
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
1 de abril de 2010
Última actualización enviada que cumplió con los criterios de control de calidad
31 de marzo de 2010
Última verificación
1 de marzo de 2010
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 07-0042
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .