Product Performance of a Daily Disposable Contact Lens
A Study to Assess the Product Performance of a Daily Disposable Contact Lens
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Singapore, Singapore, 556741
- Bausch & Lomb
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Subjects must be females of Chinese descent and of legal age and no older than 38. OR subjects that are females of Chinese descent and are at least 15 years of age and less than the legal age must: have a parent/legal guardian provide informed consent.
- Subjects must have clear central corneas and be free of any anterior segment disorders.
- Subjects must be adapted current wearers of marketed opaque tinted soft contact lenses, wear their lenses two days or more per week, and wear a lens in each eye.
Exclusion Criteria:
- Subjects who have worn gas permeable (GP) contact lenses within the last 30 days or have worn polymethylmethacrylate (PMMA) lenses within the last three months.
- Subjects who have any systemic disease affecting ocular health.
- Subjects using any systemic or topical medications that will, in the Investigator's opinion, affect ocular physiology or lens performance.
- Subjects with an active ocular disease or are using any ocular medication.
- Subjects with any scar or neovascularization within the central 4 mm of the cornea.
- Subjects who are aphakic or amblyopic.
- Subjects who have had any corneal surgery (eg, refractive surgery).
- Subjects who currently wear monovision, multifocal, or toric contact lenses.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Muut
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Kokeellinen: Prism I
Bausch & Lomb daily disposable cosmetic tint contact lens
|
Bausch & Lomb daily disposable cosmetic tint contact lens worn on a daily disposable basis for 1 week.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Market Research Survey
Aikaikkuna: 1 week
|
Online subjective assessments that subjects responded to after wearing the study lenses for at least one week.
Subjects were asked to rate their overall opinion as: Excellent, Very Good, Good, Fair, or Poor.
|
1 week
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Lens Evaluation - Centration
Aikaikkuna: Over all study visits through 1 week
|
To determine proper lens parameters the lens relationship to the eye was observed using a slit lamp.
Lens centration, meaning the lens should provide full corneal coverage, was assessed during the slit lamp evaluation.
Findings were reported as: Excellent, Good, Fair, or Poor.
|
Over all study visits through 1 week
|
|
Lens Evaluation - Movement
Aikaikkuna: Over all study visits through 1 week
|
To determine proper lens parameters the lens relationship to the eye was observed using a slit lamp. Lens movement, meaning the lens should provide discernible movement with:
|
Over all study visits through 1 week
|
|
Visual Acuity - Distance High Contrast logMAR (Logarithm of the Minimum Angle of Resolution) Lens Visual Acuity (VA).
Aikaikkuna: Over all study visits for 1 week
|
For determination of high contrast VA, the subject was to be seated so that the distance from the subject's eyes to the logMAR chart is 6.5 feet (2.0 meters).
The chart should be at eye level for the subject.
The logMAR charts have two alternative letter sequences from 28 letters (0.3 logMAR) to 62 letters (-0.3 logMAR).
The visual acuity should be measured through the phoropter using the distance refractive correction with the addition of +0.50D to compensate for the reduced test distance of 6.5 feet (2.0 meters).
|
Over all study visits for 1 week
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Todellinen)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- 654
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .