GES:n sydämen vagaaliset vaikutukset potilailla, joilla on gastropareesi ja vagushermon toimintapotentiaali vagushermossa (GES)
Mahalaukun sähköstimulaation sydämen vagaaliset vaikutukset ja vagushermon toimintamahdollisuudet vagushermossa potilailla, joilla on gastropareesi
The objective of this study is to determine if Gastric Electrical Stimulation may influence vagal outflow via vagal afferent fibers that terminate in the Central Nervous System.
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
All patients who are going to have a GES device implanted, or who already have the device are eligible to be part of the study. They will be followed according to the time point they enter the study and its schedule. The visit procedures will be conducted at the discretion of the investigator dependent on the clinical condition of the subject at that time. The study involves EKG and vagal nerve recordings. Three EKG electrodes will be placed (one on chest and 2 on either arms or legs). Separate electrodes will be placed on the neck overlying the vagus nerves
Baseline (Pre-GES Implantation) Visit:
Subjects who are being seen in clinic for possible gastroparesis and may be a possible candidate for GES later or will be undergoing the GES implantation may have a baseline visit. . The baseline visit can be held either at the time of the clinic visit or before the GES implantation. If the baseline visit occurs on the day of the GES implantation, 2 separate EKGs will be performed, one prior to GES pacemaker device implantation for up to a duration of 5 minutes and the second one after the implantation in the recovery room. This EKG will be performed for a total duration of up to 15 minutes with 5 minute "ON", 5 minutes :OFF" and another 5 minutes in the "ON" position. At the same visit with each EKG recording separate EKG electrode will be placed on the neck overlying the vagus nerve. Vagal nerve recordings will be documented for a total duration of upto 15 minutes with approximately 5 min at "ON", 5 min "OFF" and another 5 min "ON" settings of the stimulator in conjunction with the EKG recordings.
At the baseline visit separate EKG electrodes will also be placed on the neck overlying the vagus nerve and a 5 minute recording will be made in conjunction with the EKG recordings.\ before the implantation.
If the subjects already have the GES device implanted then a baseline visit will not be required. They will be included in the study at the time the consent form is signed and will be followed as needed according to the clinic visit schedule and at the discretion and clinical judgement of the investigator.
Post-GES Implantation Visits:
The subject may be asked at the clinic visits to repeat the EKG and vagal nerve study procedures at the discretion and clinical judgment of the investigator.
EKG electrodes will be placed on the chest and arms/legs, and vagal nerve electrodes will be placed on the neck overlying the vagus nerve. A butterfly catheter is inserted under aseptic conditions into a peripheral vein. Fifteen ml (1 tablespoon) of blood is withdrawn and placed on ice (labeled Baseline). With the subject at rest recordings may be made for upto a total duration of 15- 20 minutes. After 15- 20 minutes of recordings the GES device is then turned "OFF" and recordings will be made for up to 40 minutes. After 40 minutes additional 15 ml (1 tablespoon) of blood is withdrawn after the device has been in the OFF position for 40 minutes (labeled "OFF"). The device is then turned back in the "ON" position with the GES settings either at the original or changed settings from the previous settings based on the clinical judgement of the investigators, The EKG and vagal recordings may be made for up to 15-20 minutes. After 15- 20 minutes in the ON position 15 ml (1 tablespoon) is then withdrawn (labeled "ON". The butterfly catheter is then withdrawn, and a bandage is placed at the venipuncture site. The final setting on the GES will depend on the clinical decision of the investigator based on the subject's symptoms and presentation to the clinic.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Indiana
-
Indianapolis, Indiana, Yhdysvallat, 46202
- Indiana University Hospital
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
This study will evaluate male and female patients at least 18 years of age, with gastroparesis, who will or have already undergone the implantation of a GES device (Enterra, Medtronic, Minneapolis, MN)
Kuvaus
Inclusion Criteria:
- At least 18 years of age.
- Documented diagnosis of gastroparesis.
- Will undergo implantation of a GES device or already has a GES device implanted
Exclusion Criteria:
- Pregnancy
- History of allergic reaction to EKG lead placement adhesives.
- unable to give informed consent
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Havaintomallit: CASE_ONLY
- Aikanäkymät: PROSPECTIVE
Ryhmien/kohorttien lukumäärä
Kohortit ja interventiot
Ryhmä/KohorttiRyhmä/Kohortti |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
GES subjects
male and female patients at least 18 years of age, with gastroparesis, who will or have already undergone the implantation of a GES device |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Determine if GES influences vagal outflow
Aikaikkuna: 2-3 years
|
To determine if GES may influence vagal outflow via vagal afferent fibers that terminate in the Central Nervous System; EKG electrodes will be placed on the chest, stomach, jugular, and vagas nerves. The purpose of this is to record the effects of the stimulator when on and off. The ECG signals are digitized with an ECG power amplifier, Power Lab by AD Instruments. The digitized signals are analyzed with an ECG software analysis system, Lab Chart. The analysis will look for heart rate variability, total power variability, and frequency variability. This will determine if stimulation has an effect on these levels. |
2-3 years
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Release of hormones
Aikaikkuna: 2-3 years
|
The purpose of this investigation is to determine whether gastric electrical stimulation of the stomach via a surgically implanted stimulation device is associated with gastrointestinal hormone release in human subjects. Blood draws will be obtained in tandem with each of the 3 phases of EKG recordings. The blood samples will be processed and serum will be sent to an IU Lab for Hormone analysis to see if typical hormone levels associated with digestion increase or decrease with the addition/subtraction of the gastric stimulation. |
2-3 years
|
|
Vagus nerve anatomy
Aikaikkuna: 2-3 years
|
To optimize the methods for determining electrode placement around the cervical vagus nerve. The development of a method to record and analyze compound action potentials from the vagus nerve will enhance our knowledge of the mechanism of action of VNS in the treatment of gastroparesis. |
2-3 years
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Yhteistyökumppanit
Yhteistyökumppanit
Tutkijat
Tutkijat
- Päätutkija: Thomas Nowak, MD, Indiana University
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Todellinen)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvioitu)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- EKG/Vagal Nerve
- 1206008988 (Muu tunniste: IRB)
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .