Hjertevagale effekter av GES hos pasienter med gastroparese og vagusnervevirkningspotensialer i vagusnerven (GES)
Hjertevagale effekter av gastrisk elektrisk stimulering og vagusnervevirkningspotensialer i vagusnerven hos pasienter med gastroparese
The objective of this study is to determine if Gastric Electrical Stimulation may influence vagal outflow via vagal afferent fibers that terminate in the Central Nervous System.
Studieoversikt
Status
Status
Forhold
Forhold
Intervensjon / Behandling
Intervensjon / Behandling
Detaljert beskrivelse
All patients who are going to have a GES device implanted, or who already have the device are eligible to be part of the study. They will be followed according to the time point they enter the study and its schedule. The visit procedures will be conducted at the discretion of the investigator dependent on the clinical condition of the subject at that time. The study involves EKG and vagal nerve recordings. Three EKG electrodes will be placed (one on chest and 2 on either arms or legs). Separate electrodes will be placed on the neck overlying the vagus nerves
Baseline (Pre-GES Implantation) Visit:
Subjects who are being seen in clinic for possible gastroparesis and may be a possible candidate for GES later or will be undergoing the GES implantation may have a baseline visit. . The baseline visit can be held either at the time of the clinic visit or before the GES implantation. If the baseline visit occurs on the day of the GES implantation, 2 separate EKGs will be performed, one prior to GES pacemaker device implantation for up to a duration of 5 minutes and the second one after the implantation in the recovery room. This EKG will be performed for a total duration of up to 15 minutes with 5 minute "ON", 5 minutes :OFF" and another 5 minutes in the "ON" position. At the same visit with each EKG recording separate EKG electrode will be placed on the neck overlying the vagus nerve. Vagal nerve recordings will be documented for a total duration of upto 15 minutes with approximately 5 min at "ON", 5 min "OFF" and another 5 min "ON" settings of the stimulator in conjunction with the EKG recordings.
At the baseline visit separate EKG electrodes will also be placed on the neck overlying the vagus nerve and a 5 minute recording will be made in conjunction with the EKG recordings.\ before the implantation.
If the subjects already have the GES device implanted then a baseline visit will not be required. They will be included in the study at the time the consent form is signed and will be followed as needed according to the clinic visit schedule and at the discretion and clinical judgement of the investigator.
Post-GES Implantation Visits:
The subject may be asked at the clinic visits to repeat the EKG and vagal nerve study procedures at the discretion and clinical judgment of the investigator.
EKG electrodes will be placed on the chest and arms/legs, and vagal nerve electrodes will be placed on the neck overlying the vagus nerve. A butterfly catheter is inserted under aseptic conditions into a peripheral vein. Fifteen ml (1 tablespoon) of blood is withdrawn and placed on ice (labeled Baseline). With the subject at rest recordings may be made for upto a total duration of 15- 20 minutes. After 15- 20 minutes of recordings the GES device is then turned "OFF" and recordings will be made for up to 40 minutes. After 40 minutes additional 15 ml (1 tablespoon) of blood is withdrawn after the device has been in the OFF position for 40 minutes (labeled "OFF"). The device is then turned back in the "ON" position with the GES settings either at the original or changed settings from the previous settings based on the clinical judgement of the investigators, The EKG and vagal recordings may be made for up to 15-20 minutes. After 15- 20 minutes in the ON position 15 ml (1 tablespoon) is then withdrawn (labeled "ON". The butterfly catheter is then withdrawn, and a bandage is placed at the venipuncture site. The final setting on the GES will depend on the clinical decision of the investigator based on the subject's symptoms and presentation to the clinic.
Studietype
Studietype
Registrering (Faktiske)
Registrering
Kontakter og plasseringer
Studiesteder
-
-
Indiana
-
Indianapolis, Indiana, Forente stater, 46202
- Indiana University Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Prøvetakingsmetode
Studiepopulasjon
This study will evaluate male and female patients at least 18 years of age, with gastroparesis, who will or have already undergone the implantation of a GES device (Enterra, Medtronic, Minneapolis, MN)
Beskrivelse
Inclusion Criteria:
- At least 18 years of age.
- Documented diagnosis of gastroparesis.
- Will undergo implantation of a GES device or already has a GES device implanted
Exclusion Criteria:
- Pregnancy
- History of allergic reaction to EKG lead placement adhesives.
- unable to give informed consent
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Observasjonsmodeller: CASE_ONLY
- Tidsperspektiver: PROSPECTIVE
Antall grupper / kohorter
Kohorter og intervensjoner
Gruppe / KohortGruppe / Kohort |
Intervensjon / BehandlingIntervensjon / Behandling |
|---|---|
|
GES subjects
male and female patients at least 18 years of age, with gastroparesis, who will or have already undergone the implantation of a GES device |
Hva måler studien?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Determine if GES influences vagal outflow
Tidsramme: 2-3 years
|
To determine if GES may influence vagal outflow via vagal afferent fibers that terminate in the Central Nervous System; EKG electrodes will be placed on the chest, stomach, jugular, and vagas nerves. The purpose of this is to record the effects of the stimulator when on and off. The ECG signals are digitized with an ECG power amplifier, Power Lab by AD Instruments. The digitized signals are analyzed with an ECG software analysis system, Lab Chart. The analysis will look for heart rate variability, total power variability, and frequency variability. This will determine if stimulation has an effect on these levels. |
2-3 years
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Release of hormones
Tidsramme: 2-3 years
|
The purpose of this investigation is to determine whether gastric electrical stimulation of the stomach via a surgically implanted stimulation device is associated with gastrointestinal hormone release in human subjects. Blood draws will be obtained in tandem with each of the 3 phases of EKG recordings. The blood samples will be processed and serum will be sent to an IU Lab for Hormone analysis to see if typical hormone levels associated with digestion increase or decrease with the addition/subtraction of the gastric stimulation. |
2-3 years
|
|
Vagus nerve anatomy
Tidsramme: 2-3 years
|
To optimize the methods for determining electrode placement around the cervical vagus nerve. The development of a method to record and analyze compound action potentials from the vagus nerve will enhance our knowledge of the mechanism of action of VNS in the treatment of gastroparesis. |
2-3 years
|
Samarbeidspartnere og etterforskere
Sponsor
Sponsor
Samarbeidspartnere
Samarbeidspartnere
Etterforskere
Etterforskere
- Hovedetterforsker: Thomas Nowak, MD, Indiana University
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Studiestart
Primær fullføring (Faktiske)
Primær fullføring
Studiet fullført (Faktiske)
Studiet fullført
Datoer for studieregistrering
Først innsendt
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Antatt)
Først lagt ut
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Sist oppdatering lagt ut
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
Andre studie-ID-numre
- EKG/Vagal Nerve
- 1206008988 (Annen identifikator: IRB)
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .