Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Passive Fit of Implant-Supported Frameworks: Digital vs Conventional Impressions

torstai 20. elokuuta 2026 päivittänyt: Ahmed Hazem Elsayed Helmi, Mansoura University

Passive Fit Evaluation of Full-Arch Implant-supported Frameworks Using Digital and Conventional Impression Techniques: Crossover Study

This randomized crossover clinical trial compares the passivity of fit of complete-arch mandibular implant-supported frameworks fabricated using three impression techniques: a non-calibrated splinted digital scan body system (IO-Connect), a Reverse Scan Body (RSB) digital impression technique, and a conventional splinted open-tray impression technique. Eight completely edentulous patients each receiving four mandibular implants will be included. Passivity of fit will be evaluated clinically using the Sheffield one-screw test and radiographically using intraoral periapical radiographs obtained with the parallel technique.

Tutkimuksen yleiskatsaus

Tila

Rekrytointi

Ehdot

Interventio / Hoito

Yksityiskohtainen kuvaus

Full-arch implant-supported fixed prostheses require a high degree of passive fit to avoid mechanical and biological complications. While digital impression workflows are increasingly used as alternatives to conventional splinted impressions, evidence directly comparing their clinical accuracy for complete-arch implant frameworks remains limited, particularly for the IO-Connect non-calibrated splinting system and the Reverse Scan Body technique.

Eight completely edentulous patients with at least four mandibular implants will be enrolled. Using a crossover design, each patient will undergo all three impression techniques: Group I (IO-Connect splinted scan bodies), Group II (Reverse Scan Body technique), and Group III (conventional splinted open-tray impression with polyvinyl siloxane and Type IV stone casts). For each technique, a corresponding implant-supported framework will be fabricated and evaluated for passivity of fit using the Sheffield one-screw test and periapical radiographs taken with a paralleling device to assess microgaps at the implant-framework interface.

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

8

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

  • Nimi: Ahmed H Hazem Elsayed Helmi Atwa, BDS
  • Puhelinnumero: +20 1092758696
  • Sähköposti: ahmedhazem@mans.edu.eg

Opiskelupaikat

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, Egypti
        • Rekrytointi
        • Faculty of Dentistry, Mansoura University
        • Ottaa yhteyttä:
        • Päätutkija:
          • Ahmed Hazem Elsayed Helmi Atwa, BDS

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  • Completely edentulous patients requiring full-arch implant-supported fixed prosthesis
  • Age 35-70 years
  • Adequate mandibular bone to place at least four implants without major grafting
  • Ability to undergo digital scanning and radiographic evaluation
  • Signed informed consent

Exclusion Criteria:

  • Systemic conditions affecting healing (uncontrolled diabetes, immunosuppression)
  • History of head/neck radiotherapy or bisphosphonate therapy
  • Active oral infection or severe bruxism
  • Strong gag reflex preventing accurate scanning
  • Poor compliance or unwillingness to attend follow-up visits

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Crossover-tehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Active Comparator: Group I: IO-Connect
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with IO-Connect non-calibrated splinted scan bodies.
Digital impression of the mandibular arch obtained using IO-Connect non-calibrated splinted scan bodies to fabricate the implant-supported framework for Group I.
Active Comparator: Group II: Reverse Scan Body
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with the Reverse Scan Body (RSB) technique.
Digital impression obtained using the Reverse Scan Body (RSB) technique, involving extraoral scanning of scan bodies and superimposition with intraoral tissue scans, to fabricate the implant-supported framework for Group II.
Active Comparator: Group III: Conventional Impression
Patients received complete-arch implant-supported frameworks fabricated using a conventional splinted open-tray impression technique.
Conventional splinted open-tray impression using polyvinyl siloxane material and Type IV dental stone to fabricate the implant-supported framework for Group III.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Passive Fit Assessed by Sheffield One-Screw Test
Aikaikkuna: The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
The framework was seated on all implants and a single distal screw was fully tightened; remaining screw sites were examined visually and tactilely for lifting, rocking, or gaps as an indicator of passive fit.
The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
Passive Fit Assessed by Periapical Radiographs
Aikaikkuna: The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
Intraoral periapical radiographs were obtained at each implant site using a paralleling device and evaluated for microgaps at the implant-framework interface.
The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Sponsori

Tutkijat

  • Opintojen puheenjohtaja: Fatma A El-Waseef, PhD, Mansoura University

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Sunnuntai 25. tammikuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Sunnuntai 25. lokakuuta 2026

Opintojen valmistuminen (Arvioitu)

Maanantai 25. tammikuuta 2027

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Torstai 6. elokuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Torstai 20. elokuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Perjantai 21. elokuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Perjantai 21. elokuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Torstai 20. elokuuta 2026

Viimeksi vahvistettu

Lauantai 1. elokuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Muut tutkimustunnusnumerot

  • MS.25-12-95

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

PÄÄTTÄMÄTÖN

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .