Passive Fit of Implant-Supported Frameworks: Digital vs Conventional Impressions
Passive Fit Evaluation of Full-Arch Implant-supported Frameworks Using Digital and Conventional Impression Techniques: Crossover Study
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
Full-arch implant-supported fixed prostheses require a high degree of passive fit to avoid mechanical and biological complications. While digital impression workflows are increasingly used as alternatives to conventional splinted impressions, evidence directly comparing their clinical accuracy for complete-arch implant frameworks remains limited, particularly for the IO-Connect non-calibrated splinting system and the Reverse Scan Body technique.
Eight completely edentulous patients with at least four mandibular implants will be enrolled. Using a crossover design, each patient will undergo all three impression techniques: Group I (IO-Connect splinted scan bodies), Group II (Reverse Scan Body technique), and Group III (conventional splinted open-tray impression with polyvinyl siloxane and Type IV stone casts). For each technique, a corresponding implant-supported framework will be fabricated and evaluated for passivity of fit using the Sheffield one-screw test and periapical radiographs taken with a paralleling device to assess microgaps at the implant-framework interface.
Tipo de estudo
Tipo de estudo
Inscrição (Estimado)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
Contato de estudo
- Nome: Ahmed H Hazem Elsayed Helmi Atwa, BDS
- Número de telefone: +20 1092758696
- E-mail: ahmedhazem@mans.edu.eg
Locais de estudo
-
-
Dakahlia Governorate
-
Al Mansurah, Dakahlia Governorate, Egito
- Recrutamento
- Faculty of Dentistry, Mansoura University
-
Contato:
- Ahmed H Hazem Elsayed Helmi Atwa, BDS
- Número de telefone: +20 1092758696
- E-mail: ahmedhazem@mans.edu.eg
-
Investigador principal:
- Ahmed Hazem Elsayed Helmi Atwa, BDS
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Completely edentulous patients requiring full-arch implant-supported fixed prosthesis
- Age 35-70 years
- Adequate mandibular bone to place at least four implants without major grafting
- Ability to undergo digital scanning and radiographic evaluation
- Signed informed consent
Exclusion Criteria:
- Systemic conditions affecting healing (uncontrolled diabetes, immunosuppression)
- History of head/neck radiotherapy or bisphosphonate therapy
- Active oral infection or severe bruxism
- Strong gag reflex preventing accurate scanning
- Poor compliance or unwillingness to attend follow-up visits
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Comparador Ativo: Group I: IO-Connect
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with IO-Connect non-calibrated splinted scan bodies.
|
Digital impression of the mandibular arch obtained using IO-Connect non-calibrated splinted scan bodies to fabricate the implant-supported framework for Group I.
|
|
Comparador Ativo: Group II: Reverse Scan Body
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with the Reverse Scan Body (RSB) technique.
|
Digital impression obtained using the Reverse Scan Body (RSB) technique, involving extraoral scanning of scan bodies and superimposition with intraoral tissue scans, to fabricate the implant-supported framework for Group II.
|
|
Comparador Ativo: Group III: Conventional Impression
Patients received complete-arch implant-supported frameworks fabricated using a conventional splinted open-tray impression technique.
|
Conventional splinted open-tray impression using polyvinyl siloxane material and Type IV dental stone to fabricate the implant-supported framework for Group III.
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Passive Fit Assessed by Sheffield One-Screw Test
Prazo: The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
|
The framework was seated on all implants and a single distal screw was fully tightened; remaining screw sites were examined visually and tactilely for lifting, rocking, or gaps as an indicator of passive fit.
|
The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
|
|
Passive Fit Assessed by Periapical Radiographs
Prazo: The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
|
Intraoral periapical radiographs were obtained at each implant site using a paralleling device and evaluated for microgaps at the implant-framework interface.
|
The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Cadeira de estudo: Fatma A El-Waseef, PhD, Mansoura University
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Estimado)
Conclusão Primária
Conclusão do estudo (Estimado)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- MS.25-12-95
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .