Full-arch implant-supported fixed prostheses require a high degree of passive fit to avoid mechanical and biological complications. While digital impression workflows are increasingly used as alternatives to conventional splinted impressions, evidence directly comparing their clinical accuracy for complete-arch implant frameworks remains limited, particularly for the IO-Connect non-calibrated splinting system and the Reverse Scan Body technique.
Eight completely edentulous patients with at least four mandibular implants will be enrolled. Using a crossover design, each patient will undergo all three impression techniques: Group I (IO-Connect splinted scan bodies), Group II (Reverse Scan Body technique), and Group III (conventional splinted open-tray impression with polyvinyl siloxane and Type IV stone casts). For each technique, a corresponding implant-supported framework will be fabricated and evaluated for passivity of fit using the Sheffield one-screw test and periapical radiographs taken with a paralleling device to assess microgaps at the implant-framework interface.
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
Estudio Contacto
- Nombre: Ahmed H Hazem Elsayed Helmi Atwa, BDS
- Número de teléfono: +20 1092758696
- Correo electrónico: ahmedhazem@mans.edu.eg
Ubicaciones de estudio
-
-
Dakahlia Governorate
-
Al Mansurah, Dakahlia Governorate, Egipto
- Reclutamiento
- Faculty of Dentistry, Mansoura University
-
Contacto:
- Ahmed H Hazem Elsayed Helmi Atwa, BDS
- Número de teléfono: +20 1092758696
- Correo electrónico: ahmedhazem@mans.edu.eg
-
Investigador principal:
- Ahmed Hazem Elsayed Helmi Atwa, BDS
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Completely edentulous patients requiring full-arch implant-supported fixed prosthesis
- Age 35-70 years
- Adequate mandibular bone to place at least four implants without major grafting
- Ability to undergo digital scanning and radiographic evaluation
- Signed informed consent
Exclusion Criteria:
- Systemic conditions affecting healing (uncontrolled diabetes, immunosuppression)
- History of head/neck radiotherapy or bisphosphonate therapy
- Active oral infection or severe bruxism
- Strong gag reflex preventing accurate scanning
- Poor compliance or unwillingness to attend follow-up visits
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Comparador activo: Group I: IO-Connect
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with IO-Connect non-calibrated splinted scan bodies.
|
Digital impression of the mandibular arch obtained using IO-Connect non-calibrated splinted scan bodies to fabricate the implant-supported framework for Group I.
|
|
Comparador activo: Group II: Reverse Scan Body
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with the Reverse Scan Body (RSB) technique.
|
Digital impression obtained using the Reverse Scan Body (RSB) technique, involving extraoral scanning of scan bodies and superimposition with intraoral tissue scans, to fabricate the implant-supported framework for Group II.
|
|
Comparador activo: Group III: Conventional Impression
Patients received complete-arch implant-supported frameworks fabricated using a conventional splinted open-tray impression technique.
|
Conventional splinted open-tray impression using polyvinyl siloxane material and Type IV dental stone to fabricate the implant-supported framework for Group III.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Passive Fit Assessed by Sheffield One-Screw Test
Periodo de tiempo: The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
|
The framework was seated on all implants and a single distal screw was fully tightened; remaining screw sites were examined visually and tactilely for lifting, rocking, or gaps as an indicator of passive fit.
|
The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
|
|
Passive Fit Assessed by Periapical Radiographs
Periodo de tiempo: The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
|
Intraoral periapical radiographs were obtained at each implant site using a paralleling device and evaluated for microgaps at the implant-framework interface.
|
The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Silla de estudio: Fatma A El-Waseef, PhD, Mansoura University
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- MS.25-12-95
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .