- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT03327610
Selecting the Best Ventilator Hyperinflation Settings (VHI1)
Selecting the Best Ventilator Hyperinflation Settings Based on Physiologic Markers: Randomized Controlled Study
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Yksityiskohtainen kuvaus
Background: Ventilator Hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, there are no recommendations on the best ventilator settings to perform the technique. Thus, the aim of this study was to compare six modes of VHI, concerning physiological markers of efficacy and safety criteria, in order to support the optimal VHI settings selection for mechanically ventilated patients.
Methods: In a crossover study, every included mechanically ventilated patient underwent six modes of VHI in a randomized order: Volume Control Continuous Mandatory Ventilation (VC-CMV) with inspiratory flow = 20Lpm (VC-CMV20), VC-CMV with inspiratory flow = 50Lpm (VC-CMV50), Pressure Control Continuous Mandatory Ventilation (PC-CMV) with inspiratory time = 1s. (PC-CMV1), PC-CMV with inspiratory time = 3s. (PC-CMV3), Pressure Support Ventilation (PSV) with cycling off = 10% of peak inspiratory flow (PSV10), and PSV with cycling off = 25% of peak inspiratory flow (PSV25). The maximum expansion (tidal volume), expiratory flow bias criteria (inspiratory and expiratory flow patterns), over-distension (alveolar pressure), asynchronies and hemodynamic variables (mean arterial pressure and heart rate) were assessed during the interventions.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Patients under mechanical ventilation for more than 48h
Exclusion Criteria:
- mucus hypersecretion (defined as the need for suctioning < 2-h intervals),
- absence of respiratory drive,
- atelectasis,
- severe bronchospasm,
- positive end expiratory pressure > 10cmH2O,
- PaO2-FiO2 relationship < 150,
- mean arterial pressure < 60mmHg,
- inotrope requirement equivalent to >15 ml/h total of adrenaline and noradrenalin,
- intracranial pressure > 20mmHg
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Crossover-tehtävä
- Naamiointi: Yksittäinen
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Ei väliintuloa: BASELINE
The subjects were kept in their current ventilatory mode.
|
|
|
Kokeellinen: VC-CMV20
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory flow of 20Lpm.
|
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV).
The inspiratory flow was set at 20Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
|
Kokeellinen: VC-CMV50
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory flow of 50Lpm.
|
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV).
The inspiratory flow was set at 50Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
|
Kokeellinen: PC-CMV1
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1) with an inspiratory time of 1 second.
|
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1).
The inspiratory time was set at 1 second and the pressure control was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
|
Kokeellinen: PC-CMV3
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1) with an inspiratory time of 3 seconds.
|
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1).
The inspiratory time was set at 3 seconds and the pressure control was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
|
Kokeellinen: PSV10
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV) with a cycling off of 10% of peak inspiratory flow.
|
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV).
The cycling off was set at 10% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
|
Kokeellinen: PSV25
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV) with a cycling off of 25% of peak inspiratory flow.
|
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV).
The cycling off was set at 25% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Peak inspiratory to expiratory flow ratio
Aikaikkuna: Ten minutes after the onset of intervention.
|
Dichotomous variable, defined as achieving a peak inspiratory flow rate (PIFR) less than 90% of the peak expiratory flow rate (PEFR)
|
Ten minutes after the onset of intervention.
|
|
Peak expiratory flow higher than 40 Lpm
Aikaikkuna: Ten minutes after the onset of intervention.
|
Dichotomous variable, defined as achieving a PEFR higher than 40 l/min
|
Ten minutes after the onset of intervention.
|
|
Difference between peak inspiratory and expiratory flows.
Aikaikkuna: Ten minutes after the onset of intervention.
|
Dichotomous variable, defined as achieving a difference higher than 17Lpm.
|
Ten minutes after the onset of intervention.
|
|
Pulmonary expansion
Aikaikkuna: Ten minutes after the onset of intervention.
|
Percentage of tidal volume above the normal tidal volume (estimated as 6mL/kg).
|
Ten minutes after the onset of intervention.
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Mean arterial pressure
Aikaikkuna: Ten minutes after the onset of intervention.
|
Mean arterial pressure verified using the multi-parameter monitor.
|
Ten minutes after the onset of intervention.
|
|
Heart Rate
Aikaikkuna: Ten minutes after the onset of intervention.
|
Heart rate verified using the multi-parameter monitor.
|
Ten minutes after the onset of intervention.
|
Yhteistyökumppanit ja tutkijat
Sponsori
Yhteistyökumppanit
Tutkijat
- Opintojen puheenjohtaja: FERNANDO S GUIMARAES, PhD, Centro Universitário Augusto Motta
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Berney S, Denehy L. A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients. Physiother Res Int. 2002;7(2):100-8. doi: 10.1002/pri.246.
- Lemes DA, Zin WA, Guimaraes FS. Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial. Aust J Physiother. 2009;55(4):249-54. doi: 10.1016/s0004-9514(09)70004-2.
- Thomas PJ. The effect of mechanical ventilator settings during ventilator hyperinflation techniques: a bench-top analysis. Anaesth Intensive Care. 2015 Jan;43(1):81-7. doi: 10.1177/0310057X1504300112.
- Ntoumenopoulos G, Shannon H, Main E. Do commonly used ventilator settings for mechanically ventilated adults have the potential to embed secretions or promote clearance? Respir Care. 2011 Dec;56(12):1887-92. doi: 10.4187/respcare.01229. Epub 2011 Jun 17.
- Anderson A, Alexanders J, Sinani C, Hayes S, Fogarty M. Effects of ventilator vs manual hyperinflation in adults receiving mechanical ventilation: a systematic review of randomised clinical trials. Physiotherapy. 2015 Jun;101(2):103-10. doi: 10.1016/j.physio.2014.07.006. Epub 2014 Oct 6.
- Davies JD, Senussi MH, Mireles-Cabodevila E. Should A Tidal Volume of 6 mL/kg Be Used in All Patients? Respir Care. 2016 Jun;61(6):774-90. doi: 10.4187/respcare.04651.
- de Wit M. Monitoring of patient-ventilator interaction at the bedside. Respir Care. 2011 Jan;56(1):61-72. doi: 10.4187/respcare.01077.
Hyödyllisiä linkkejä
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- VHI1
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .
Kliiniset tutkimukset VC-CMV20
-
University of ArizonaValmisIhotauti/iho - MuutYhdysvallat
-
ViaCyteCalifornia Institute for Regenerative Medicine (CIRM)LopetettuTyypin 1 diabetes mellitusKanada, Yhdysvallat
-
National Defense Medical Center, TaiwanValmisKipu, akuutti | Lapsen käyttäytyminen | Fysiologinen stressi | RintamaitoTaiwan
-
ViaCyteLopetettuTyypin 1 diabetesYhdysvallat
-
VA Office of Research and DevelopmentEi vielä rekrytointiaKrooninen keuhkoahtaumatautiYhdysvallat
-
Queen's University, BelfastAWARE NI; Northern Ireland Public Health Research NetworkValmisMasennusYhdistynyt kuningaskunta
-
University Medical Center GroningenLopetettu
-
ViaCyteValmisTyypin 1 diabetes mellitusKanada
-
ViaCyteVertex Pharmaceuticals Incorporated; California Institute for Regenerative... ja muut yhteistyökumppanitValmisTyypin 1 diabetes mellitus hypoglykemiallaYhdysvallat, Kanada, Belgia
-
Sunnybrook Health Sciences CentreCanadian Initiative for Outcomes in Rheumatology CareLopetettuTulehduksellinen niveltulehdusKanada